MBR functioning under steady and unsteady state conditions. Impact on performances and membrane fouling dynamics

被引:12
|
作者
Lebegue, J. [1 ]
Heran, M. [1 ]
Grasmick, A. [1 ]
机构
[1] Univ Montpellier 2, UMR Genie Procedes Eau & Bioproduits 016, CIRAD, F-34095 Montpellier 05, France
关键词
Air lift; Fouling control; Membrane bioreactor; Wastewater treatment;
D O I
10.1016/j.desal.2007.12.009
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
This paper presents MBR performances observed under steady and unsteady state conditions where influent and permeate flow rates were punctually and simultaneously increased. Experiments were performed in a submerged membrane bioreactor presenting a 50 L working volume. Two capillary membrane modules, M1 and M2 (Koch systems) were placed on the outside of the bioreactor in a side stream position. Air was injected below each membrane module, ensuring vertical air lift circulation. To point out the role of the air membrane on membrane fouling control, different air flow rates were practised (1.36 m(3).m(-2).L-1 and 0.45 respectively for M1 and M2). Results confirm the high capacity of MBR to withstand high loading rate variations namely because of the total biomass retention by the membrane barrier whatever the biomass flocculation state. Under continuous extensive filtration conditions (10 LMH permeate flow rate) no significant differences were observed between TMP evolution for modules M1 and M2. Nevertheless, the results highlighted the determining role of the air membrane flow rate in controlling fouling reversibility when working in intensive filtration conditions (30 LMH) without any back-washing or relaxation procedure.
引用
收藏
页码:209 / 218
页数:10
相关论文
共 50 条
  • [21] Al-Fe hypoeutectic alloys directionally solidified under steady-state and unsteady-state conditions
    Goulart, P. R.
    Spinelli, J. E.
    Cheung, N.
    Mangelinck-Noeel, N.
    Garcia, A.
    JOURNAL OF ALLOYS AND COMPOUNDS, 2010, 504 (01) : 205 - 210
  • [23] Performance of an air membrane bioreactor for methanol removal under steady and transient state conditions
    Prikyai, Kamonkarn
    Watsuntorn, Wannapawn
    Rene, Eldon R.
    Visvanathan, Chettiyappan
    CHEMOSPHERE, 2020, 260 (260)
  • [24] Dynamics of ribosomes in mRNA translation under steady- and nonsteady-state conditions
    Szavits-Nossan, Juraj
    Evans, Martin R.
    PHYSICAL REVIEW E, 2020, 101 (06)
  • [26] BASIS-TRANSFORMED STATE SPACE FORMULATION FOR THE ANALYSIS OF CONTROLLED RECTIFIERS UNDER IDEAL AND NON-IDEAL STEADY STATE CONDITIONS.
    Cheung, R.W.-Y.
    Lavers, J.D.
    IEEE Transactions on Power Systems, 1986, PWRS-1 (04): : 137 - 144
  • [27] SELECTIVITY PROPERTIES OF SODIUM GLASS MEMBRANE ELECTRODES UNDER NON-STEADY-STATE CONDITIONS
    WANGSA, J
    ARNOLD, MA
    ANALYTICAL CHEMISTRY, 1987, 59 (13) : 1604 - 1608
  • [28] Behaviour of the current in a membrane-covered disc microelectrode under steady-state conditions
    Galceran, J
    Salvador, J
    Puy, J
    Cecilia, J
    Gavaghan, DJ
    ANALYST, 1996, 121 (12) : 1863 - 1868
  • [29] MEMBRANE-PERMEABILITY OF MUSCLE FIBERS TO SODIUM IONS UNDER STEADY-STATE CONDITIONS
    ABRAMENK.YM
    TSITOLOGIYA, 1973, 15 (04): : 406 - 414
  • [30] Performance Assessment of a New Type of Membrane Bioreactor under Steady State and Transient Operating Conditions
    Medella, Ali
    Suidan, Makram T.
    Venosa, Albert D.
    JOURNAL OF ENVIRONMENTAL ENGINEERING, 2011, 137 (09) : 817 - 825