The effect of pore geometry on the mechanical properties of selective laser melted Ti-13Nb-13Zr scaffolds

被引:40
|
作者
Speirs, M. [1 ]
Van Humbeeck, J.
Schrooten, J.
Luyten, J.
Kruth, J. P. [1 ]
机构
[1] Katholieke Univ Leuven, Dept Mech Engn, PMA, B-3001 Louvain, Belgium
关键词
Powder metallurgy; Porous material: Biomedical alloys; Compressive strength; Selective laser melting; Bone tissue engineering; BEHAVIOR; MODELS;
D O I
10.1016/j.procir.2013.01.016
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Selective laser melting (SLM) is a promising technique for the production of biometallic scaffolds for orthopedic applications due to its ability for fast turnover times and production of customised complex geometrical parts. The present work demonstrates the production of various unit cell design scaffolds of low E-modulus Ti-xNb-yZr beta titanium. 3 Unit cells were produced at 3 different pore sizes (1000, 750 and 500 mu m). Micro-CT and compression testing was carried out for each design showing a stiffness range within the range of bone. (C) 2013 The Authors. Published by Elsevier B.V.
引用
收藏
页码:79 / 82
页数:4
相关论文
共 50 条
  • [41] Effects of Ta content on phase transformation in selective laser melting processed Ti-13Nb-13Zr alloy and its correlation with elastic properties
    Zhou, Libo
    Chen, Jian
    Huang, WeiYing
    Ren, Yanjie
    Niu, Yan
    Yuan, Tiechui
    VACUUM, 2021, 183
  • [42] BACTERIAL INTERACTION WITH TI-13NB-13ZR AND OTHER DENTAL MATERIALS
    BABU, JP
    DABBOUS, MK
    KOVACS, P
    MISHRA, A
    DAIGLE, K
    DAVIDSON, JA
    JOURNAL OF DENTAL RESEARCH, 1995, 74 : 190 - 190
  • [43] Corrosion resistance of anodic oxides on the Ti-50Zr and Ti-13Nb-13Zr alloys
    Oliveira, NTC
    Ferreira, EA
    Duarte, LT
    Biaggio, SR
    Rocha, RC
    Bocchi, N
    ELECTROCHIMICA ACTA, 2006, 51 (10) : 2068 - 2075
  • [44] Biological Activity and Thrombogenic Properties of Oxide Nanotubes on the Ti-13Nb-13Zr Biomedical Alloy
    Stroz, Agnieszka
    Gawlikowski, Maciej
    Balin, Katarzyna
    Osak, Patrycja
    Kubisztal, Julian
    Zubko, Maciej
    Maszybrocka, Joanna
    Dudek, Karolina
    Losiewicz, Bozena
    JOURNAL OF FUNCTIONAL BIOMATERIALS, 2023, 14 (07)
  • [45] The effect of hydrogen peroxide on the electrochemical behaviour of Ti-13Nb-13Zr alloy in Hanks' solution
    IPEN, CNEN-SP, Centro de Ciência e Tecnologia de Materiais - CCTM, Av. Prof. Lineu Prestes, 2242, 05508-900 São Paulo - SP, Brazil
    Mater. Res., 2006, 4 (425-429):
  • [46] Optimization of process parameters of laser composite surfaced Ti-13Nb-13Zr using Taguchi method
    Bera, Tapas
    Manna, Indranil
    Akinlabi, Esther Titilayo
    Majumdar, Jyotsna Dutta
    INDIAN JOURNAL OF ENGINEERING AND MATERIALS SCIENCES, 2024, 31 (04) : 515 - 523
  • [47] Microstructure, Micro-Mechanical and Tribocorrosion Behavior of Oxygen Hardened Ti-13Nb-13Zr Alloy
    Lukaszczyk, Alicja
    Zimowski, Slawomir
    Pawlak, Wojciech
    Dubiel, Beata
    Moskalewicz, Tomasz
    MATERIALS, 2021, 14 (08)
  • [48] Corrosion Resistance Of Laser Nitrided Commercially Pure Titanium And Ti-13Nb-13Zr Biomedical Alloys
    Sathish, S.
    Anbarasan, V.
    Geetha, M.
    Asokamani, R.
    TRANSACTIONS OF THE INDIAN INSTITUTE OF METALS, 2008, 61 (2-3) : 235 - 238
  • [49] Effect of HA (Hydroxyapatite) content on the microstructure, mechanical and corrosion properties of (Ti-13Nb-13Zr)-xHA biocomposites synthesized by sparkle plasma sintering
    He, Y. H.
    Zhang, Y. Q.
    Jiang, Y. H.
    Zhou, R.
    VACUUM, 2016, 131 : 176 - 180
  • [50] Corrosion resistance of laser nitrided commercially pure titanium and Ti-13Nb-13Zr biomedical alloys
    S. Sathish
    V. Anbarasan
    M. Geetha
    R. Asokamani
    Transactions of the Indian Institute of Metals, 2008, 61 : 235 - 238