Upgrade plans for the ATLAS calorimeters

被引:0
|
作者
Seifert, F. [1 ]
机构
[1] Tech Univ Dresden, Inst Kern & Teilchenphys, D-01062 Dresden, Germany
关键词
ATLAS calorimeter upgrade; Hilum;
D O I
10.1016/j.nima.2012.08.078
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The ATLAS calorimeter is composed of detectors based on different techniques to exploit the best performance while maintaining a sufficient radiation resistance. A radiation resistant liquid argon (LAr) sampling calorimeter is used for all electromagnetic sections, for the endcap (HEC) and forward (FCal) hadronic sections. The most central hadronic section is, instead, a steel-scintillator sampling calorimeter (TileCal). Plans are already being developed for operation of the LHC and the detectors at an increased instantaneous luminosity about 5 times the original design value. There are plans for a two-phase detector upgrade. For Phase I, the LAr calorimeter trigger will be upgraded. For Phase II, the TileCal upgrade consists in replacing the on- and off-detector electronics and for the LAr system includes changes to the DAQ the HEC cold electronics and the FCal. Development work for these options includes high rate tests of small test modules of the endcap and forward detectors. (C) 2012 CERN. Published by Elsevier BY. All rights reserved.
引用
收藏
页码:16 / 20
页数:5
相关论文
共 50 条
  • [42] LHCb upgrade plans
    Muheim, F.
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2007, 170 : 317 - 322
  • [43] Upgrade plans for VERITAS
    Zitzer, Benjamin
    PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON TECHNOLOGY AND INSTRUMENTATION IN PARTICLE PHYSICS (TIPP 2011), 2012, 37 : 1365 - 1372
  • [44] Hadron response and shower development in the ATLAS calorimeters
    Simonyan, Margar
    XIV INTERNATIONAL CONFERENCE ON CALORIMETRY IN HIGH ENERGY PHYSICS (CALOR 2010), 2011, 293
  • [45] Signal feedthroughs for the ATLAS barrel and endcap calorimeters
    Axen, D
    Hackenburg, R
    Hoffmann, A
    Kane, S
    Lissauer, D
    Makowiecki, D
    Muller, T
    Pate, D
    Radeka, V
    Rahm, D
    Rehak, M
    Rescia, S
    Sexton, K
    Sondericker, J
    Birney, P
    Dowling, AW
    Fincke-Keeler, M
    Hodges, T
    Holness, F
    Honkanen, N
    Keeler, R
    Langstaff, R
    Lenckowski, M
    Lefebvre, M
    Poffenberger, P
    Vowles, G
    Oram, C
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2005, 76 (06):
  • [46] The readout system of the ATLAS liquid argon calorimeters
    Blondel, A
    La Marra, D
    Léger, A
    Perrot, G
    Poggioli, L
    Prast, J
    Riu, I
    Simion, S
    PROCEEDINGS OF THE EIGHTH WORKSHOP ON ELECTRONICS FOR LHC EXPERIMENTS, 2002, 2002 (03): : 313 - 316
  • [47] Readout Driver for the ATLAS Liquid Argon calorimeters
    Cleland, WE
    PROCEEDINGS OF THE FIFTH WORKSHOP ON ELECTRONICS FOR LHC EXPERIMENTS, 1999, : 366 - 370
  • [48] Performance of the ATLAS Liquid Argon Calorimeter after three years of LHC operation and plans for a future upgrade
    Ilic, N.
    JOURNAL OF INSTRUMENTATION, 2014, 9
  • [49] Performance of the ATLAS Liquid Argon Calorimeter after three years of LHC operation and plans for a future upgrade
    Strizenec, P.
    JOURNAL OF INSTRUMENTATION, 2014, 9
  • [50] Performance of the ATLAS Liquid Argon Calorimeter after Three Years of LHC Operation and Plans for a Future Upgrade
    Nikiforou, Nikiforos
    2013 3RD INTERNATIONAL CONFERENCE ON ADVANCEMENTS IN NUCLEAR INSTRUMENTATION, MEASUREMENT METHODS AND THEIR APPLICATIONS (ANIMMA), 2013,