Upgrade plans for the ATLAS calorimeters

被引:0
|
作者
Seifert, F. [1 ]
机构
[1] Tech Univ Dresden, Inst Kern & Teilchenphys, D-01062 Dresden, Germany
关键词
ATLAS calorimeter upgrade; Hilum;
D O I
10.1016/j.nima.2012.08.078
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The ATLAS calorimeter is composed of detectors based on different techniques to exploit the best performance while maintaining a sufficient radiation resistance. A radiation resistant liquid argon (LAr) sampling calorimeter is used for all electromagnetic sections, for the endcap (HEC) and forward (FCal) hadronic sections. The most central hadronic section is, instead, a steel-scintillator sampling calorimeter (TileCal). Plans are already being developed for operation of the LHC and the detectors at an increased instantaneous luminosity about 5 times the original design value. There are plans for a two-phase detector upgrade. For Phase I, the LAr calorimeter trigger will be upgraded. For Phase II, the TileCal upgrade consists in replacing the on- and off-detector electronics and for the LAr system includes changes to the DAQ the HEC cold electronics and the FCal. Development work for these options includes high rate tests of small test modules of the endcap and forward detectors. (C) 2012 CERN. Published by Elsevier BY. All rights reserved.
引用
收藏
页码:16 / 20
页数:5
相关论文
共 50 条
  • [1] ATLAS upgrade plans for the SLHC
    Tseng, J.
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2008, 177 : 212 - 216
  • [2] ATLAS and CMS Upgrade Plans
    Parzefall, Ulrich
    14TH INTERNATIONAL CONFERENCE OF B-PHYSICS AT HADRON MACHINES (BEAUTY 2013), 2013,
  • [3] Upgrade of the Trigger System of the ATLAS Liquid Argon Calorimeters
    Kanaya, N.
    2014 19TH IEEE-NPSS REAL TIME CONFERENCE (RT), 2014,
  • [4] ATLAS: status, limitations and upgrade plans
    Kawamoto, T.
    PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON TECHNOLOGY AND INSTRUMENTATION IN PARTICLE PHYSICS (TIPP 2011), 2012, 37 : 170 - 180
  • [5] Trigger readout electronics upgrade for the ATLAS Liquid Argon Calorimeters
    Dinkespiler, B.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [6] Upgrade project and plans for the ATLAS detector and trigger
    Pastore, Francesca
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 718 : 7 - 10
  • [7] Plans for the Phase II upgrade to the ATLAS detector
    Huffman, B. T.
    JOURNAL OF INSTRUMENTATION, 2014, 9
  • [8] Upgrade Project and Plans for the ATLAS Detector and Trigger
    Vari, Riccardo
    2012 18TH IEEE-NPSS REAL TIME CONFERENCE (RT), 2012,
  • [9] SLHC upgrade plans for the ATLAS pixel detector
    Sicho, Petr
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 607 (01): : 31 - 34
  • [10] Upgrade of the ATLAS Liquid Argon Calorimeters for the High-Luminosity LHC
    McCarthy, T. G.
    2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,