Encapsulation of proteins in hydrogel carrier systems for controlled drug delivery: Influence of network structure and drug size on release rate

被引:112
|
作者
Bertz, Andreas [1 ]
Woehl-Bruhn, Stefanie [2 ]
Miethe, Sebastian [3 ]
Tiersch, Brigitte [4 ]
Koetz, Joachim [4 ]
Hust, Michael [3 ]
Bunjes, Heike [2 ]
Menzel, Henning [1 ]
机构
[1] Tech Univ Carolo Wilhelmina Braunschweig, Inst Tech Chem, D-38106 Braunschweig, Germany
[2] Tech Univ Carolo Wilhelmina Braunschweig, Inst Pharmaceut Technol, D-38106 Braunschweig, Germany
[3] Tech Univ Carolo Wilhelmina Braunschweig, Inst Biochem & Biotechnol, D-38106 Braunschweig, Germany
[4] Univ Potsdam, Inst Chem, D-14476 Potsdam, Germany
关键词
Hydrogel; Hydrogel microspheres; Network structure; Release studies; Protein delivery; Mesh size; ANTIBODY GENE LIBRARIES; MICROSPHERES; THERAPEUTICS; HYDROXYETHYL; SELECTION; DEXTRAN; DESIGN;
D O I
10.1016/j.jbiotec.2012.06.036
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Novel hydrogels based on hydroxyethyl starch modified with polyethylene glycol methacrylate (HES-P(EG)(6)MA) were developed as delivery system for the controlled release of proteins. Since the drug release behavior is supposed to be related to the pore structure of the hydrogel network the pore sizes were determined by cryo-SEM, which is a mild technique for imaging on a nanometer scale. The results showed a decreasing pore size and an increase in pore homogeneity with increasing polymer concentration. Furthermore, the mesh sizes of the hydrogels were calculated based on swelling data. Pore and mesh size were significantly different which indicates that both structures are present in the hydrogel. The resulting structural model was correlated with release data for bulk hydrogel cylinders loaded with FITC-dextran and hydrogel microspheres loaded with FITC-IgG and FITC-dextran of different molecular size. The initial release depended much on the relation between hydrodynamic diameter and pore size while the long term release of the incorporated substances was predominantly controlled by degradation of the network of the much smaller meshes. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:243 / 249
页数:7
相关论文
共 50 条
  • [31] Composite hydrogel contact lens systems for naringenin: A comparison of drug loading and release behaviour in drug carrier systems
    Faran, Syed Ali
    Nguyen, Dan Chau Thuy
    Dowling, Joseph
    Ryan, Richie
    McLoughlin, Peter
    Fitzhenry, Laurence
    JOURNAL OF DRUG DELIVERY SCIENCE AND TECHNOLOGY, 2024, 102
  • [32] Sol-gel carrier systems for controlled drug delivery
    Feinchemie GmbH Sebnitz, Höhenweg 9, D-01855 Sebnitz, Germany
    不详
    J Sol Gel Sci Technol, 1-3 (277-281):
  • [33] Sol-gel carrier systems for controlled drug delivery
    Böttcher, H
    Slowik, P
    Süss, W
    JOURNAL OF SOL-GEL SCIENCE AND TECHNOLOGY, 1998, 13 (1-3) : 277 - 281
  • [34] Sol-Gel Carrier Systems for Controlled Drug Delivery
    H. Böttcher
    P. Slowik
    W. Süß
    Journal of Sol-Gel Science and Technology, 1998, 13 : 277 - 281
  • [36] Nanocarrier-hydrogel composite delivery systems for precision drug release
    Kass, Lauren E.
    Nguyen, Juliane
    WILEY INTERDISCIPLINARY REVIEWS-NANOMEDICINE AND NANOBIOTECHNOLOGY, 2022, 14 (02)
  • [37] Mechanism of gentamicin sulphate release in nanocomposite hydrogel drug delivery systems
    Sirousazar, M.
    JOURNAL OF DRUG DELIVERY SCIENCE AND TECHNOLOGY, 2013, 23 (06) : 619 - 621
  • [38] Studies on pectins as potential hydrogel matrices for controlled-release drug delivery
    Sungthongjeen, S
    Pitaksuteepong, T
    Somsiri, A
    Sriamornsak, P
    DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 1999, 25 (12) : 1271 - 1276
  • [39] Controlled vancomycin release from a biodegradable hydrogel ocular drug delivery system
    Dosmar, Emily
    Mieler, William F.
    Mieler, Jennifer J. Kang
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [40] POLYMERIC CONTROLLED RELEASE SYSTEMS - NEW METHODS FOR DRUG DELIVERY
    LAURENCIN, CT
    LANGER, R
    CLINICS IN LABORATORY MEDICINE, 1987, 7 (02) : 301 - 323