An improved powered ankle-foot orthosis using proportional myoelectric control

被引:233
|
作者
Ferris, Daniel P.
Gordon, Keith E.
Sawicki, Gregory S.
Peethambaran, Arnmanath
机构
[1] Univ Michigan, Dept Movement Sci, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA
[3] Univ Michigan, Orthot & Prosthet Ctr, Ann Arbor, MI 48109 USA
基金
美国国家卫生研究院;
关键词
locomotion; exoskeleton; gait; rehabilitation;
D O I
10.1016/j.gaitpost.2005.05.004
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
We constructed a powered ankle-foot orthosis for human walking with a novel myoelectric controller. The orthosis included a carbon fiber and polypropylene shell, a metal hinge joint, and two artificial pneumatic muscles. Soleus electromyography (EMG) activated the artificial plantar flexor and inhibited the artificial dorsiflexor. Tibialis anterior EMG activated the artificial dorsiflexor. We collected kinematic, kinetic, and electromyographic data for a naive healthy subject walking with the orthosis. The current design improves upon a previous prototype by being easier to don and doff and simpler to use. The novel controller allows naive wearers to quickly adapt to the orthosis without artificial muscle co-contraction. The orthosis may be helpful in studying human walking biomechanics and assisting patients during gait rehabilitation after neurological injury. (C) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:425 / 428
页数:4
相关论文
共 50 条
  • [31] An EMG Signal Processing System for Control of an Ankle-foot Orthosis
    Gmerek, Artur J.
    Davoodi, Mohammadreza
    Meskin, Nader
    Jaber, Fadi
    2017 4TH INTERNATIONAL CONFERENCE ON CONTROL, DECISION AND INFORMATION TECHNOLOGIES (CODIT), 2017, : 444 - 449
  • [32] Powered ankle-foot prosthesis
    Biomechatronics Group, MIT Media Lab., Cambridge, MA 02139, United States
    IEEE Rob Autom Mag, 2008, 3 (52-59):
  • [33] SEVERE ANKLE SPRAINS - TREATMENT WITH AN ANKLE-FOOT ORTHOSIS
    LANE, SE
    PHYSICIAN AND SPORTSMEDICINE, 1990, 18 (11): : 43 - &
  • [34] Use of bivalved ankle-foot orthosis in neuropathic foot and ankle lesions
    Boninger, ML
    Leonard, JA
    JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 1996, 33 (01): : 16 - 22
  • [35] A pneumatically powered knee-ankle-foot orthosis (KAFO) with myoelectric activation and inhibition
    Sawicki, Gregory S.
    Ferris, Daniel P.
    JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2009, 6
  • [36] A pneumatically powered knee-ankle-foot orthosis (KAFO) with myoelectric activation and inhibition
    Gregory S Sawicki
    Daniel P Ferris
    Journal of NeuroEngineering and Rehabilitation, 6
  • [37] A Powered Ankle-Foot Orthoses for Ankle Rehabilitation
    Bai, Yang
    Li, Fangxing
    Zhao, Jun
    Li, Jingyi
    Jin, Fei
    Gao, Xueshan
    2012 IEEE INTERNATIONAL CONFERENCE ON AUTOMATION AND LOGISTICS (ICAL), 2012, : 288 - 293
  • [38] Design of a Portable Hydraulic Ankle-Foot Orthosis
    Neubauer, Brett C.
    Nath, Jonathan
    Durfee, William K.
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 1182 - 1185
  • [39] STIFFNESS ANALYSIS OF A SIMPLIFIED ANKLE-FOOT ORTHOSIS
    Swierski, Ethan
    Burke, Molly
    Arenas, Maria
    Bernat, Jessica
    Manzer, James
    Piovesan, Davide
    PROCEEDINGS OF THE ASME 2020 INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, IMECE2020, VOL 5, 2020,
  • [40] KNEE-STABILIZING ANKLE-FOOT ORTHOSIS
    RUBIN, G
    DANISI, M
    ORTHOTICS AND PROSTHETICS, 1975, 29 (03): : 11 - 14