Integrated Structural and Energy Retrofitting of Masonry Walls: Effect of In-Plane Damage on the Out-of-Plane Response

被引:33
|
作者
Gkournelos, P. D. [1 ]
Triantafillou, T. C. [1 ]
Bournas, D. A. [2 ]
机构
[1] Univ Patras, Dept Civil Engn, Patras 26500, Greece
[2] European Commiss, Joint Res Ctr, I-21027 Ispra, VA, Italy
关键词
Energy retrofitting; In-plane loading; Masonry walls; Out-of-plane loading; Strengthening; Textile reinforced mortar; REINFORCED-CONCRETE FRAMES; BEHAVIOR; RC; COMPOSITES; CAPACITY; INFILLS;
D O I
10.1061/(ASCE)CC.1943-5614.0001066
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A total of 12 experiments were carried out to evaluate the effect of prior in-plane damage on the out-of-plane response of structurally and thermally retrofitted masonry wallettes, simulating simply the behavior of upgraded masonry infills in frame structures under seismic loading. The specimens were retrofitted with textile-reinforced mortar (TRM), which in some cases was combined with expanded polystyrene as thermal insulation material. Testing comprised in-plane diagonal compression and out-of-plane bending on walls with or without prior in-plane damage. Numerical simulations were also performed using fiber modeling, and they were found in good agreement with test results. The experimental results showed that in-plane loaded walls with TRM only or TRM/insulation retrofitting outperformed significantly their nonretrofitted counterparts. Out-of-plane loaded walls with combined TRM/thermal insulation performed much better than, or at least as well as, their TRM-only retrofitted counterparts, for the case with or without prior in-plane damage, respectively.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Out-of-plane strength reduction of unreinforced masonry walls because of in-plane damages
    Dolatshahi, Kiarash M.
    Yekrangnia, Mohammad
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2015, 44 (13): : 2157 - 2176
  • [22] Behavior of Confined Masonry Walls with Openings under In-Plane and Out-of-Plane Loads
    Singhal, Vaibhav
    Rai, Durgesh C.
    EARTHQUAKE SPECTRA, 2018, 34 (02) : 817 - 841
  • [23] Definition of interaction curves for the in-plane and out-of-plane capacity in brick masonry walls
    Najafgholipour, M. A.
    Maheri, Mahmoud R.
    Lourenco, P. B.
    CONSTRUCTION AND BUILDING MATERIALS, 2014, 55 : 168 - 182
  • [24] Influence of the in plane and out-of-plane masonry infill walls' interaction in the structural response of RC buildings
    Furtado, Andre
    Rodrigues, Hugo
    Arede, Antonio
    Varum, Humberto
    ICSI 2015 THE 1ST INTERNATIONAL CONFERENCE ON STRUCTURAL INTEGRITY FUNCHAL, 2015, 114 : 722 - 729
  • [25] OUT-OF-PLANE SEISMIC RESPONSE OF REINFORCED MASONRY WALLS
    BUTTON, MR
    MAYES, RL
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1992, 118 (09): : 2495 - 2513
  • [26] In-plane and out-of-plane response of a masonry infill divided into smaller wallettes
    Vintzileou, E.
    Adami, C. E.
    Palieraki, V
    BRICK AND BLOCK MASONRY: TRENDS, INNOVATIONS AND CHALLENGES, 2016, : 1367 - 1373
  • [27] Fragility functions for masonry infill walls in RC frames with the in-plane and out-of-plane loading
    Liu, Wen
    Jin, Wei
    Zhai, Changhai
    JOURNAL OF BUILDING ENGINEERING, 2024, 95
  • [28] Out-of-plane seismic retrofitting of masonry walls with Textile Reinforced Mortar composites
    Stefano De Santis
    Gerardo De Canio
    Gianmarco de Felice
    Pietro Meriggi
    Ivan Roselli
    Bulletin of Earthquake Engineering, 2019, 17 : 6265 - 6300
  • [29] Out-of-plane seismic retrofitting of masonry walls with Textile Reinforced Mortar composites
    De Santis, Stefano
    De Canio, Gerardo
    de Felice, Gianmarco
    Meriggi, Pietro
    Roselli, Ivan
    BULLETIN OF EARTHQUAKE ENGINEERING, 2019, 17 (11) : 6265 - 6300
  • [30] Retrofitting Masonry Walls against Out-Of-Plane Loading with Timber Based Panels
    Iuorio, Ornella
    Dauda, Jamiu A.
    APPLIED SCIENCES-BASEL, 2021, 11 (12):