Integrated Structural and Energy Retrofitting of Masonry Walls: Effect of In-Plane Damage on the Out-of-Plane Response

被引:33
|
作者
Gkournelos, P. D. [1 ]
Triantafillou, T. C. [1 ]
Bournas, D. A. [2 ]
机构
[1] Univ Patras, Dept Civil Engn, Patras 26500, Greece
[2] European Commiss, Joint Res Ctr, I-21027 Ispra, VA, Italy
关键词
Energy retrofitting; In-plane loading; Masonry walls; Out-of-plane loading; Strengthening; Textile reinforced mortar; REINFORCED-CONCRETE FRAMES; BEHAVIOR; RC; COMPOSITES; CAPACITY; INFILLS;
D O I
10.1061/(ASCE)CC.1943-5614.0001066
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A total of 12 experiments were carried out to evaluate the effect of prior in-plane damage on the out-of-plane response of structurally and thermally retrofitted masonry wallettes, simulating simply the behavior of upgraded masonry infills in frame structures under seismic loading. The specimens were retrofitted with textile-reinforced mortar (TRM), which in some cases was combined with expanded polystyrene as thermal insulation material. Testing comprised in-plane diagonal compression and out-of-plane bending on walls with or without prior in-plane damage. Numerical simulations were also performed using fiber modeling, and they were found in good agreement with test results. The experimental results showed that in-plane loaded walls with TRM only or TRM/insulation retrofitting outperformed significantly their nonretrofitted counterparts. Out-of-plane loaded walls with combined TRM/thermal insulation performed much better than, or at least as well as, their TRM-only retrofitted counterparts, for the case with or without prior in-plane damage, respectively.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Integrated Structural and Energy Retrofitting of Masonry Walls: The Effect of In-Plane Damage on the Out-Of-Plane Response
    Gkournelos, Panagiotis
    Triantafillou, Thanasis
    10TH INTERNATIONAL CONFERENCE ON FRP COMPOSITES IN CIVIL ENGINEERING (CICE 2020/2021), 2022, 198 : 1819 - 1836
  • [2] Effect of in-plane damage on the out-of-plane strength of masonry walls with openings
    Patel, Kaushal P.
    Dubey, R. N.
    STRUCTURES, 2024, 65
  • [3] Effect of in-plane damage on out-of-plane strength of unreinforced masonry walls
    Agnihotri, Pawan
    Singhal, Vaibhav
    Rai, Durgesh C.
    ENGINEERING STRUCTURES, 2013, 57 : 1 - 11
  • [4] Effect of prior in-plane damage on the out-of-plane behavior of masonry infill walls
    Xie, Xianxin
    Qu, Zhe
    Fu, Haoran
    Zhang, Lingxin
    ENGINEERING STRUCTURES, 2021, 226
  • [5] Masonry Walls under Combined In-Plane and Out-of-Plane Loadings
    Noor-E-Khuda, Sarkar
    Dhanasekar, Manicka
    JOURNAL OF STRUCTURAL ENGINEERING, 2018, 144 (02)
  • [6] Numerical Investigation on the Influence of In-Plane Damage on the Out-of-Plane Behavior of Masonry Infill Walls
    Wang, Xiaomin
    Zhao, Weitong
    Kong, Jingchang
    Zhao, Tiejun
    ADVANCES IN CIVIL ENGINEERING, 2020, 2020
  • [7] Effect of In-Plane Damage on Out-of-Plane Response of FRCM Strengthened Masonry Infilled RC Frames
    Selvaraj, Bhushan Raj
    Rai, Durgesh C.
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2022, 26 (06)
  • [8] A three-dimensional macroelement for modelling the in-plane and out-of-plane response of masonry walls
    Vanin, Francesco
    Penna, Andrea
    Beyer, Katrin
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2020, 49 (14): : 1365 - 1387
  • [9] In-plane and out-of-plane homogenisation of masonry
    Mistler, M.
    Anthoine, A.
    Butenweg, C.
    COMPUTERS & STRUCTURES, 2007, 85 (17-18) : 1321 - 1330
  • [10] Effect of prior in-plane damage on the out-of-plane performance of concrete masonry infills
    Nasiri, Ehsan
    Liu, Yi
    Engineering Structures, 2020, 222