Evaluating Component Migration: Comparing Two Generations of the INBONE® Total Ankle Replacement

被引:3
|
作者
Brigido, Stephen A. [1 ]
Wobst, Garrett M. [2 ]
Galli, Melissa M. [3 ]
Protzman, Nicole M. [4 ]
机构
[1] Coordinated Hlth, Foot & Ankle Reconstruct, Foot & Ankle Dept, Bethlehem, PA USA
[2] Avera Orthoped Surg Specialists, Aberdeen, SD USA
[3] CORE Inst, Phoenix, AZ USA
[4] Coordinated Hlth, Clin Educ & Res Dept, Allentown, PA USA
来源
JOURNAL OF FOOT & ANKLE SURGERY | 2015年 / 54卷 / 05期
关键词
ankle joint surgery; joint prosthesis; osteoarthritis; subsidence; total ankle replacement; FOLLOW-UP; PERIOPERATIVE COMPLICATIONS; HINTEGRA ANKLE; SHORT-TERM; ARTHROPLASTY;
D O I
10.1053/j.jfas.2015.03.004
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Although total ankle replacement (TAR) designs have radically evolved, the compressive forces at the ankle can cause aseptic loosening, talar subsidence, and implant failure. The purpose of the present report was to compare the implant migration associated with the INBONE (R) I, a TAR system with a stemmed talar component, and the newer generation INBONE (R) II, a TAR system without a stemmed talar component (Wright Medical Technology, Inc., Arlington, TN). Because core decompression could weaken the integrity of the talus, we hypothesized that the stemmed component would result in greater implant migration. A total of 35 consecutive patients (age 58.2 +/- 12.1 years; 23 men) were included. Of these 35 patients, 20 (57.1%) had been treated with the INBONE (R) I and 15 (42.9%) with the INBONE (R) II. To assess implant migration, using anteroposterior radiographs, the distance from the apex of the tibial component to the most distal aspect of the talar stem or to the mid-saddle of the nonstemmed component was measured. The measurements were recorded from the immediate postoperative radiographs and the 12-month postoperative radiographs. Implant migration was quantified as the difference between the 12-month and the immediate postoperative measurements. Despite our hypothesis, no significant difference was found in implant migration between the INBONE (R) I (0.7 +/- 1.2 mm) and INBONE (R) II (0.6 +/- 1.3 mm, p = .981). However, previously published data have suggested that implant migration can continue for >= 2 years after surgery. Therefore, additional investigations with larger sample sizes and longer follow-up periods are needed to draw definitive conclusions. (C) 2015 by the American College of Foot and Ankle Surgeons. All rights reserved.
引用
收藏
页码:892 / 895
页数:4
相关论文
共 50 条
  • [21] Total Ankle Replacement with Use of a New Three-Component Implant
    Rippstein, Pascal F.
    Huber, Martin
    Coetzee, Chris
    Naal, Florian D.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A (15): : 1426 - 1435
  • [22] Total Replacement of Varus Ankle Three-Component Prosthesis Design
    Hintermann, Beat
    Ruiz, Roxa
    FOOT AND ANKLE CLINICS, 2019, 24 (02) : 305 - +
  • [23] Two-Year Revision Rates in Total Ankle Replacement Versus Ankle Arthrodesis
    Randsborg, Per-Henrik
    Jiang, Hongying
    Mao, Jialin
    Devlin, Vincent
    Marinac-Dabic, Danica
    Peat, Raquel
    Sedrakyan, Art
    JBJS OPEN ACCESS, 2022, 7 (02)
  • [24] Total ankle replacement with INBONE-II prosthesis: A short-to- medium-term follow-up study in China
    Wu, Yong
    Yang, Hanyuan
    Guo, Xiangbin
    Du, Hui
    Gong, Xiaofeng
    CHINESE MEDICAL JOURNAL, 2022, 135 (12) : 1459 - 1465
  • [25] Can a Three-Component Prosthesis be Used for Conversion of Painful Ankle Arthrodesis to Total Ankle Replacement?
    Preis, Markus
    Bailey, Travis
    Marchand, Lucas S.
    Barg, Alexej
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2017, 475 (09) : 2283 - 2294
  • [26] Development and validation of a numerical model for tibial component analysis in total ankle replacement
    Terrier, A.
    Larrea, X.
    Guerdat, J.
    Crevoisier, X.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2013, 16 : 249 - 250
  • [27] Preventing tibial and talar component contact during implantation of a total ankle replacement
    Roche, A. J.
    Calder, J. D.
    ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2013, 95 (01) : 74 - 75
  • [28] Early migration of the tibial component of the Buechel-Pappas total ankle prosthesis
    Nelissen, Rob G. H. H.
    Doets, H. Cornelis
    Valstar, Edward R.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (448) : 146 - 151
  • [29] Reliability of the Phi angle to assess rotational alignment of the talar component in total ankle replacement
    Manzi, Luigi
    Villafane, Jorge Hugo
    Indino, Cristian
    Tamini, Jacopo
    Berjano, Pedro
    Usuelli, Federico Giuseppe
    FOOT AND ANKLE SURGERY, 2019, 25 (02) : 169 - 173
  • [30] Motion at the Tibial and Polyethylene Component Interface in a Mobile-Bearing Total Ankle Replacement
    Lundeen, Gregory A.
    Clanton, Thomas O.
    Dunaway, Linda J.
    Lu, Minggen
    FOOT & ANKLE INTERNATIONAL, 2016, 37 (08) : 848 - 854