Validation of Compound Poisson Noise Model for Computed Tomography with Energy-integrating Detector

被引:0
|
作者
Zamyatin, Alexander A. [1 ]
Fan, Yi [1 ]
Schultz, Kurt [1 ]
Nakanishi, Satoru [2 ]
机构
[1] Toshiba Med Res Inst USA Inc, Vernon Hills, IL 60061 USA
[2] Toshiba Med Syst Corp, Toshiba, Japan
关键词
DOSE-REDUCTION; CT;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
These instructions provide guidelines for preparing manuscripts for submission to the Conference Record (CR) of the 2012 IEEE Nuclear Science Symposium and Medical Imaging Conference. If you are using Microsoft Word 6.0 or later to prepare your manuscript, you should use this document as a template. Define all symbols used in the abstract. Do not cite references in the abstract.
引用
收藏
页码:2689 / 2691
页数:3
相关论文
共 50 条
  • [31] Low-dose CT of the abdomen: Initial experience on a novel photon-counting detector CT and comparison with energy-integrating detector CT
    Decker, Josua A.
    Bette, Stefanie
    Lubina, Nora
    Rippel, Katharina
    Braun, Franziska
    Risch, Franka
    Wollny, Claudia
    Scheurig-Muenkler, Christian
    Kroencke, Thomas J.
    Schwarz, Florian
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 148
  • [32] Intraindividual Comparison of Ultrahigh-Spatial-Resolution Photon-Counting Detector CT and Energy-Integrating Detector CT for Coronary Stenosis Measurement
    Vecsey-Nagy, Milan
    Tremamunno, Giuseppe
    Schoepf, U. Joseph
    Gnasso, Chiara
    Zsarnoczay, Emese
    Fink, Nicola
    Kravchenko, Dmitrij
    Halfmann, Moritz C.
    Laux, Gerald S.
    O'Doherty, Jim
    Szilveszter, Balint
    Maurovich-Horvat, Pal
    Kabakus, Ismail Mikdat
    Suranyi, Pal Spruill
    Varga-Szemes, Akos
    Emrich, Tilman
    CIRCULATION-CARDIOVASCULAR IMAGING, 2024, 17 (10)
  • [33] Coronary Plaque Quantification with Ultrahigh-Spatial-Resolution Photon-counting Detector CT: Intraindividual Comparison with Energy-integrating Detector CT
    Vecsey-Nagy, Milan
    Tremamunno, Giuseppe
    Schoepf, U. Joseph
    Gnasso, Chiara
    Zsarnoczay, Emese
    Fink, Nicola
    Kravchenko, Dmitrij
    Halfmann, Moritz C.
    O'Doherty, Jim
    Szilveszter, Balint
    Maurovich-Horvat, Pal
    Kabakus, Ismail Mikdat
    Suranyi, Pal Spruill
    Emrich, Tilman
    Varga-Szemes, Akos
    RADIOLOGY, 2025, 314 (03)
  • [34] Intra-individual comparison of coronary artery stenosis measurements between energy-integrating detector CT and photon-counting detector CT
    Wolf, Elias V.
    Gnasso, Chiara
    Schoepf, U. Joseph
    Halfmann, Moritz C.
    O'Doherty, Jim
    Zsarnoczay, Emese
    Varga-Szemes, Akos
    Emrich, Tilman
    Fink, Nicola
    IMAGING, 2023, 15 (02): : 61 - 68
  • [35] Photon-counting detector CT and energy-integrating detector CT for trabecular bone microstructure analysis of cubic specimens from human radius
    Klintstrom, Benjamin
    Henriksson, Lilian
    Moreno, Rodrigo
    Malusek, Alexandr
    Smedby, Orjan
    Woisetschlager, Mischa
    Klintstrom, Eva
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2022, 6 (01)
  • [36] Improved display and detection of small renal stones using photon-counting detector CT compared to conventional energy-integrating detector CT
    Esquivel, Andrea
    Potretzke, Theodora
    Ferrero, Andrea
    Inoue, Akitoshi
    Hoodeshenans, Safa
    Mileto, Achille
    Winfree, Timothy
    Yalon, Mariana
    Khandelwal, Ashish
    Rajendran, Kishore
    Thorne, Jamison E.
    Lee, Yong S.
    Potretzke, Aaron
    Leng, Shuai
    Mccollough, Cynthia H.
    Fletcher, Joel G.
    ABDOMINAL RADIOLOGY, 2025,
  • [37] Efficiency of TV-regularized algorithms in computed tomography with Poisson-Gaussian noise
    Leuliet, Theo
    Friot--Giroux, Louise
    Baaziz, Walid
    Bretin, Elie
    Ersen, Ovidiu
    Peyrin, Francoise
    Sixou, Bruno
    Maxim, Voichita
    28TH EUROPEAN SIGNAL PROCESSING CONFERENCE (EUSIPCO 2020), 2021, : 1294 - 1298
  • [38] Photon-counting detector CT provides superior subsolid nodule characterization compared to same-day energy-integrating detector CT
    Wang, Jinhua
    Huang, Zhicheng
    Zhu, Zhenchen
    Wang, Baiyu
    Han, Wei
    Hu, Ge
    Ying, Zhoumeng
    Yu, Yang
    Wang, Yadong
    Pan, Zhengsong
    Wang, Daoyun
    Song, Yang
    Li, Haochen
    Liu, Lei
    Song, Lan
    Liang, Naixin
    Song, Wei
    EUROPEAN RADIOLOGY, 2024,
  • [39] Bone Mineral Density Quantification from Localizer Radiographs: Accuracy and Precision of Energy-integrating Detector CT and Photon-counting Detector CT
    Nowak, Tristan
    Eberhard, Matthias
    Schmidt, Bernhard
    Frey, Diana
    Distler, Oliver
    Saltybaeva, Natalia
    Alkadhi, Hatem
    Euler, Andre
    RADIOLOGY, 2021, 298 (01) : 147 - 152
  • [40] Photon-counting detector CT reduces the rate of referrals to invasive coronary angiography as compared to CT with whole heart coverage energy-integrating detector
    Simon, Judit
    Hrenko, Aron
    Kerkovits, Nora Melinda
    Nagy, Kristof
    Vertes, Miklos
    Balogh, Hanna
    Nagy, Norbert
    Munkacsi, Tamas
    Emrich, Tilman
    Varga-Szemes, Akos
    Boussoussou, Melinda
    Vattay, Borbala
    Vecsey-Nagy, Milan
    Kolossvary, Marton
    Szilveszter, Balint
    Merkely, Bela
    Maurovich-Horvat, Pal
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2024, 18 (01) : 69 - 74