New instrument that uses near-infrared spectroscopy for the monitoring of human muscle oxygenation

被引:28
|
作者
Muellner, T
Nikolic, A
Schramm, W
Vécsei, V
机构
[1] Univ Vienna, Clin Traumatol, Vienna, Austria
[2] Univ Vienna, Clin Anaesthesiol, Vienna, Austria
关键词
D O I
10.1097/00005373-199906000-00021
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Early detection of vascular impairments after free tissue transfers are essential to prevent flap failure. Near-infrared spectroscopy showed good promise to monitor flaps at deep le, els successfully without being invasive. The purpose of this study was to test whether the INVOS 3100 cerebral oxymeter is capable of detecting circulatory impairments. Methods: In 10 healthy adults, near-infrared spectroscopy was used to measure regional saturation values during tourniquet ischemia and venous outflow restriction, in two test cycles. The probe, containing an infrared-light-emitting source and two infrared-light sensors, was placed below the elbow above the brachioradialis muscle. Statistical comparison of the data nas performed using the Friedman test and the Wilcoxon-Wilcox test, Results: Venous and arterial occlusions were characterized by an instantaneous fall of the regional saturation. Arterial occlusion showed a mean decrease of the saturation values down to 28 +/- 9%, whereas venous occlusion showed a mean fall of saturation values down to 51 +/- 12%. These falls were significant after 3 minutes of occlusion compared with baseline values (74 +/- 6%). The differences between arterial and venous occlusions were statistically significant, Conclusion: This study, designed to test less expensive equipment, was able to measure absolute values, and was not prone to interference caused by probe movement, providing information on the oxygenation profile accurately and noninvasively, and distinguishing between arterial and venous occlusion.
引用
收藏
页码:1082 / 1084
页数:3
相关论文
共 50 条
  • [21] Phenylephrine increases near-infrared spectroscopy determined muscle oxygenation in men
    Sorensen, H.
    Thomsen, J. H.
    Meyer, A. S. P.
    Terzic, D.
    Hilsted, L.
    Kjaergaard, J.
    Goetze, J. P.
    Barbosa, T. C.
    Secher, N. H.
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2017, 31 (06) : 1159 - 1166
  • [22] EVALUATION OF MUSCLE OXYGENATION DURING CONSTANT WORKLOAD WITH NEAR-INFRARED SPECTROSCOPY
    Samejima, M.
    Hamaoka, T.
    Nishio, S.
    Sako, T.
    Honma, T.
    Ichimura, S.
    Tsurumi, Y.
    Katsumura, T.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2001, 33 (05): : S327 - S327
  • [23] Phenylephrine increases near-infrared spectroscopy determined muscle oxygenation in men
    H. Sørensen
    J. H. Thomsen
    A. S. P. Meyer
    D. Terzic
    L. Hilsted
    J. Kjærgaard
    J. P. Goetze
    T. C. Barbosa
    N. H. Secher
    Journal of Clinical Monitoring and Computing, 2017, 31 : 1159 - 1166
  • [24] Near-infrared spectroscopy: More than just monitoring brain oxygenation
    Vutskits, Laszlo
    Skowno, Justin
    PEDIATRIC ANESTHESIA, 2022, 32 (03) : 394 - 395
  • [25] Near-infrared spectroscopy of the placenta for monitoring fetal oxygenation during labour
    Razem, Katja
    Kocijan, Jus
    Podbregar, Matej
    Lucovnik, Miha
    PLOS ONE, 2020, 15 (04):
  • [26] Relationship between blood oxygenation and lactate in human skeletal muscle revealed by near-infrared spectroscopy
    Xu, GD
    Luo, QM
    Ge, XF
    Gong, H
    Zeng, SQ
    INTERNATIONAL WORKSHOP ON PHOTONICS AND IMAGING IN BIOLOGY AND MEDICINE, 2001, 4536 : 177 - 181
  • [27] Simultaneous functional near-infrared spectroscopy and electroencephalography for monitoring of human brain activity and oxygenation: a review
    Chiarelli, Antonio M.
    Zappasodi, Filippo
    Di Pompeo, Francesco
    Merla, Arcangelo
    NEUROPHOTONICS, 2017, 4 (04)
  • [28] Near-infrared spectroscopy for monitoring of tissue oxygenation of exercising skeletal muscle in a chronic compartment syndrome model
    Breit, GA
    Gross, JH
    Watenpaugh, DE
    Chance, B
    Hargens, AR
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (06): : 838 - 843
  • [29] Systematic review of clinical applications of monitoring muscle tissue oxygenation with near-infrared spectroscopy in vascular disease
    Boezeman, Reinout P. E.
    Moll, Frans L.
    Unlu, Cagdas
    de Vries, Jean-Paul P. M.
    MICROVASCULAR RESEARCH, 2016, 104 : 11 - 22
  • [30] Near-Infrared Spectroscopy in Studies of Brain Oxygenation
    Eda, Hideo
    CURRENT PHARMACEUTICAL BIOTECHNOLOGY, 2013, 14 (02) : 167 - 171