Burden of atrial fibrillation and poor rate control detected by continuous monitoring and the risk for heart failure hospitalization

被引:45
|
作者
Sarkar, Shantanu [1 ]
Koehler, Jodi [1 ]
Crossley, George H. [2 ,3 ]
Tang, W. H. Wilson [4 ]
Abraham, William T. [5 ]
Warman, Eduardo N. [1 ]
Whellan, David J. [6 ]
机构
[1] Medtronic Inc, Mounds View, MN USA
[2] St Thomas Res Inst, Nashville, TN USA
[3] Univ Tennessee, Coll Med, Nashville, TN USA
[4] Cleveland Clin, Cleveland, OH 44106 USA
[5] Ohio State Univ, Columbus, OH 43210 USA
[6] Thomas Jefferson Univ, Philadelphia, PA 19107 USA
关键词
VENTRICULAR SYSTOLIC DYSFUNCTION; QUALITY-OF-CARE; MANAGEMENT; TRIAL; MORTALITY; PROGRAM; DRONEDARONE; ABLATION; NETWORK; STROKE;
D O I
10.1016/j.ahj.2012.06.020
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction Atrial fibrillation (AF) on electrocardiogram has been identified as a risk factor for hospitalizations in patients with heart failure (HF). We investigated whether continuous AF monitoring can identify when patients with HF are at risk for hospitalization. Methods In this retrospective analysis of data from 4 studies enrolling patients with HF with cardiac resynchronization therapy defibrillator devices with >= 90 days of follow-up (n = 1561), patients were identified as having AF if they had >= 1 day of >5 minutes of AF and >1 hour of total AF during entire follow-up. In patients with AF, device recorded AF burden (AFb) and ventricular rate during AF (VRAF) over the last 30 days was classified on a monthly basis into 3 evaluation groups: (1) >= 1 day of high burden of paroxysmal AF (>= 6 hours) or persistent AF (all 30 days with AFb >23 hours) with poor rate control (VRAF >90 beats/min), (2) >= 1 day of high burden of paroxysmal AF with good rate control (VRAF <= 90 beats/min), and (3) no days with high burden of AF (AFb <6 hours) or persistent AF with good rate control. Each group was compared with monthly evaluations in patients without AF using an Anderson-Gill model for occurrence of HF hospitalizations in the next 30 days. Results Patients with AF (n = 519, 33%) have a greater risk (hazard ratio [HR] 2.0, P < .001) for impending HF hospitalizations during entire follow-up compared with patients with no AF. One day of high burden of paroxysmal AF with good rate control in the last 30 days increases risk for HF hospitalization in the next 30 days (HR 3.4, P < .001). The risk increases further (HR 5.9, P < .001) with 1 day of poor rate control during persistent AF or high burden paroxysmal AF in last 30 days. Conclusion Evaluation of AFb and rate control information on a monthly basis can identify patients at risk for HF hospitalization in the next 30 days. (Am Heart J 2012;164:616-24.)
引用
收藏
页码:616 / 624
页数:9
相关论文
共 50 条
  • [21] RATE-CONTROL IN PATIENTS WITH ATRIAL FIBRILLATION AND HEART FAILURE
    DeLosSantos, Marci
    Jackson, Daniel
    Shami, Nadia
    CRITICAL CARE MEDICINE, 2009, 37 (12) : A106 - A106
  • [22] The behavior of atrial fibrillation in patients with heart failure hospitalization
    Fukunaga, M.
    Hirose, K.
    Isotani, A.
    Morinaga, T.
    Ando, K.
    EUROPEAN HEART JOURNAL, 2019, 40 : 3957 - 3957
  • [23] Heart Failure in Patients With Atrial Fibrillation Is Associated With a High Symptom and Hospitalization Burden: The RealiseAF Survey
    Silva-Cardoso, Jose
    Zharinov, Oleg J.
    Ponikowski, Piotr
    Naditch-Brule, Lisa
    Lewalter, Thorsten
    Brette, Sandrine
    Steg, P. Gabriel
    CLINICAL CARDIOLOGY, 2013, 36 (12) : 766 - 774
  • [24] Progression of Device-Detected Subclinical Atrial Fibrillation and the Risk of Heart Failure
    Wong, Jorge A.
    Conen, David
    Van Gelder, Isabelle C.
    McIntyre, William F.
    Crijns, Harry J.
    Wang, Jia
    Gold, Michael R.
    Hohnloser, Stefan H.
    Lau, C. P.
    Capucci, Alessandro
    Botto, Gianluca
    Groenefeld, Gerian
    Israel, Carsten W.
    Connolly, Stuart J.
    Healey, Jeff S.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (23) : 2603 - 2611
  • [25] Atrial fibrillation in heart failure: drug therapies for rate and rhythm control
    Rafik Tadros
    Paul Khairy
    Jean L. Rouleau
    Mario Talajic
    Peter G. Guerra
    Denis Roy
    Heart Failure Reviews, 2014, 19 : 315 - 324
  • [26] Congestive heart failure and atrial fibrillation: Rhythm versus rate control
    Kareti, KR
    Chiong, JR
    Hsu, SS
    Miller, AB
    JOURNAL OF CARDIAC FAILURE, 2005, 11 (03) : 164 - 172
  • [27] Ablation versus rate control in patients with heart failure and atrial fibrillation
    Estes, N. A. Mark, III
    HEART RHYTHM, 2022, 19 (06) : 1037 - 1037
  • [28] Rate or rhythm control?: In patients with atrial fibrillation and nonischaemic heart failure
    Ökçün, B
    Yigit, Z
    Arat, A
    Kucukoglu, S
    EUROPEAN HEART JOURNAL, 2004, 25 : 397 - 397
  • [29] Persistent atrial fibrillation worsens heart rate variability, activity and heart rate, as shown by a continuous monitoring by implantable biventricular pacemakers in heart failure patients
    Puglisi, Andrea
    Gasparini, Maurizio
    Lunati, Maurizio
    Sassara, Massimo
    Padeletti, Luigi
    Landolina, Maurizio
    Botto, Giovanni Luca
    Vincenti, Antonio
    Bianchi, Stefano
    Denaro, Alessandra
    Grammatico, Andrea
    Boriani, Giuseppe
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2008, 19 (07) : 693 - 701
  • [30] Atrial fibrillation and heart failure: beyond the heart rate
    Garg, Anuj
    Akoum, Nazem
    CURRENT OPINION IN CARDIOLOGY, 2013, 28 (03) : 332 - 336