Development of a micro gas chromatograph for the analysis of hydrogen isotope gas mixtures in the fusion fuel cycle

被引:25
|
作者
Kawamura, Y [1 ]
Konishi, S [1 ]
Nishi, V [1 ]
机构
[1] Japan Atom Res Inst, Tritium Engn Lab, Dept Fus Engn Res, Tokai, Ibaraki 3191195, Japan
关键词
hydrogen isotope; gas chromatography; fusion reactor; retention time;
D O I
10.1016/S0920-3796(01)00378-7
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Analysis of hydrogen isotopes is very important in the fuel cycle system of fusion reactors. Gas chromatography with a cryogenic separation column is one of the most extensively used methods for the analysis of hydrogen isotopes. Micro gas chromatograph (micro GC) with a cryogenic column is expected to improve the analysis time, that is a major disadvantage of conventional GC. The present authors have modified the micro GC to use its separation column at cryogenic temperature. In previous work a micro packed column has been tested and indicated fairly good performance. In this work a capillary column was tested at cryogenic temperature for more improvement of analysis time. Obtained retention time of H(2), HD and D(2) were about 43, 47 and 5.4 s, respectively, for the column with 0.53 mm of I.D., 4.0 m of length and 0.08 mm of film thickness. Peak resolution between H(2) and HD was about 1.12. These results suggest that the column developed in this work attained the practical level for the separation and short analysis time. The estimation of the retention time was carried out using the dispersion model. The retention times of HT, DT and T(2) were also estimated using the reduced. mass. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:389 / 394
页数:6
相关论文
共 50 条
  • [31] PREPARATION OF GAS-MIXTURES FOR CALIBRATION OF A CHROMATOGRAPH BY A VOLUMETRIC GAS-FLOW METHOD
    BRASSENS, A
    ANALUSIS, 1975, 3 (10) : 576 - 579
  • [32] Microfabricated gas chromatograph for trace analysis
    Pai, Rekha S.
    Mott, David R.
    Stepnowski, Jennifer L.
    McGill, R. Andrew
    Higgins, Bernadette A.
    Simonson, Duane L.
    2008 IEEE CONFERENCE ON TECHNOLOGIES FOR HOMELAND SECURITY, VOLS 1 AND 2, 2008, : 150 - +
  • [33] METHANOL ANALYSIS BY GAS-CHROMATOGRAPH
    BLACKWELL, BR
    MURRAY, FE
    OLDHAM, WK
    SVENSK PAPPERSTIDNING-NORDISK CELLULOSA, 1979, 82 (16): : 477 - 480
  • [34] THE CHEMICAL MICRO-ANALYSIS OF BINARY GAS MIXTURES
    TOMPKINS, FC
    JOURNAL OF SCIENTIFIC INSTRUMENTS, 1950, 27 (08): : 224 - 225
  • [35] The micro gas analysis of argon-nitrogen mixtures
    Van Liempt, JAM
    Van Wijk, W
    RECUEIL DES TRAVAUX CHIMIQUES DES PAYS-BAS, 1937, 56 : 310 - 314
  • [36] CONVERSION OF SULFUR COMPOUNDS TO HYDROGEN SULFIDE IN AIR, FUEL GAS, OR MIXTURES
    FOGO, JK
    POPOWSKY, M
    ANALYTICAL CHEMISTRY, 1949, 21 (06) : 734 - 737
  • [37] Cycle analysis of micro gas turbine-solid oxide fuel cell hybrid system
    Uechi, Hideyuki
    Kimijima, Shinji
    Kasagi, Nobuhide
    Nippon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B, 2002, 68 (666): : 626 - 635
  • [38] Cycle analysis of micro gas turbine-molten carbonate fuel cell hybrid system
    Kimijima, S
    Kasagi, N
    JSME INTERNATIONAL JOURNAL SERIES B-FLUIDS AND THERMAL ENGINEERING, 2005, 48 (01) : 65 - 74
  • [39] ANALYSIS OF ORGANIC MIXTURES USING COMBINATION OF A THERMOGRAVIMETRIC ANALYZER, A GAS CHROMATOGRAPH AND AN INFRARED SPECTROPHOTOMETER
    CUKOR, P
    LANNING, EW
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1971, 9 (08) : 487 - &
  • [40] Micro Gas Chromatograph for Harsh Refinery Gas Environment: Microvalves Based on PEEK Membranes
    Nachef, K.
    Bourlon, B.
    Danaie, K.
    Guieze, P.
    Donzier, E.
    Marty, F.
    Bourouina, T.
    2009 IEEE SENSORS, VOLS 1-3, 2009, : 1082 - +