Evaluation of the Impact of Three-Dimensional Vision on Laparoscopic Performance

被引:90
|
作者
Lusch, Achim [1 ]
Bucur, Philip L. [1 ]
Menhadji, Ashleigh D. [1 ]
Okhunov, Zhamshid [1 ]
Liss, Michael Andre [1 ]
Perez-Lanzac, Alberto [1 ]
McDougall, Elspeth M. [1 ]
Landman, Jaime [1 ]
机构
[1] Univ Calif Irvine, Dept Urol, Orange, CA 92868 USA
关键词
CAMERA SYSTEMS; SURGERY; 2-D;
D O I
10.1089/end.2013.0344
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Recent technological advancements have led to the introduction of new three-dimensional (3D) cameras in laparoscopic surgery. The 3D view has been touted as useful during robotic surgery, however, there has been limited investigation into the utility of 3D in laparoscopy. Materials and Methods: We performed a prospective, randomized crossover trial comparing a 0 degrees 3D camera with a conventional 0 degrees two-dimensional (2D) camera using a high definition monitor (Karl Storz, Tuttlingen, Germany). All participants completed six standardized basic skills tasks. Quality testing scores were measured by the number of drops, grasping attempts, and precision of needle entry and exiting. Additionally, resolution, color distribution, depth of field and distortion were measured using optical test targets. Results: In this pilot study, we evaluated 10 medical students, 7 residents, and 7 expert surgeons. There was a significant difference in the performance in all the six skill tasks, for the three levels of surgical expertise and training levels in 2D vs 3D except for the cut the line quality score and the peg transfer quality score. Adjusting for the training level, 3D camera image results were superior for the number of rings left (p=0.041), ring transfer quality score (p=0.046), thread the rings (no. of rings) (p=0.0004), and thread the rings quality score (p=0.0002). The 3D camera image was also superior for knot tying (quality score) (p=0.004), peg transfer (time in seconds) (p=0.047), peg transfer pegs left (p=0.012), and for peg transfer quality score (p=0.001). The 3D camera system showed significantly less distortion (p=0.0008), a higher depth of field (p=0.0004) compared with the 2D camera system. Conclusion: 3D laparoscopic camera equipment results in a significant improvement in depth perception, spatial location, and precision of surgical performance compared with the conventional 2D camera equipment. With this improved quality of vision, even expert laparoscopic surgeons may benefit from 3D imaging.
引用
收藏
页码:261 / 266
页数:6
相关论文
共 50 条
  • [21] Three-dimensional displays and stereo vision
    Westheimer, Gerald
    PROCEEDINGS OF THE ROYAL SOCIETY B-BIOLOGICAL SCIENCES, 2011, 278 (1716) : 2241 - 2248
  • [22] Neural mechanisms of three-dimensional vision
    Tsutsui, KI
    Taira, M
    Sakata, H
    NEUROSCIENCE RESEARCH, 2005, 51 (03) : 221 - 229
  • [23] Performance evaluation for three-dimensional networks-on-chip
    Feero, Brett
    Pande, Partha Pratim
    IEEE COMPUTER SOCIETY ANNUAL SYMPOSIUM ON VLSI, PROCEEDINGS: EMERGING VLSI TECHNOLOGIES AND ARCHITECTURES, 2007, : 305 - +
  • [24] THREE-DIMENSIONAL MACHINE VISION.
    Bieman, Leonard H.
    Photonics Spectra, 1988, 22 (05) : 81 - 92
  • [25] THREE-DIMENSIONAL SURGERY: LAPAROSCOPIC PYELOPLASTY
    Tugcu, Volkan
    Bitkin, Alper
    Sonmezay, Erkan
    Ziypak, Tevfik
    Tasci, Ali Ihsan
    JOURNAL OF ENDOUROLOGY, 2012, 26 : A522 - A522
  • [26] Three-dimensional visualization in laparoscopic surgery
    Pietrzak, Peter
    Arya, Manit
    Joseph, Jean V.
    Patel, Hiten R. H.
    BJU INTERNATIONAL, 2006, 98 (02) : 253 - 256
  • [27] Three-dimensional navigated laparoscopic ultrasonography
    J. Harms
    H. Feussner
    M. Baumgartner
    A. Schneider
    M. Donhauser
    G. Wessels
    Surgical Endoscopy, 2001, 15 (12) : 1459 - 1462
  • [28] High velocity impact performance of three-dimensional woven composites
    Udatha, Pavani
    Kumar, Ch V. Sesha
    Nair, Nithin S.
    Naik, Niranjan K.
    JOURNAL OF STRAIN ANALYSIS FOR ENGINEERING DESIGN, 2012, 47 (07): : 419 - 431
  • [29] Performance analysis of three-dimensional integral imaging systems based on human vision
    Wang, Fang
    Zhao, Xing
    Yang, Yong
    Fang, Zhiliang
    Yuan, Xiaocong
    OPTIK, 2013, 124 (02): : 134 - 138
  • [30] Three-dimensional imaging improved the laparoscopic performance of inexperienced operators: a prospective trial
    Shingo Kanaji
    Ryohei Watanabe
    Pietro Mascagni
    Fabian Trauzettel
    Takeshi Urade
    Fabio Longo
    Ludovica Guerriero
    Silvana Perretta
    Bernard Dallemagne
    Yoshihiro Kakeji
    Jacques Marescaux
    Surgical Endoscopy, 2020, 34 : 5083 - 5091