Evaluation of the Impact of Three-Dimensional Vision on Laparoscopic Performance

被引:90
|
作者
Lusch, Achim [1 ]
Bucur, Philip L. [1 ]
Menhadji, Ashleigh D. [1 ]
Okhunov, Zhamshid [1 ]
Liss, Michael Andre [1 ]
Perez-Lanzac, Alberto [1 ]
McDougall, Elspeth M. [1 ]
Landman, Jaime [1 ]
机构
[1] Univ Calif Irvine, Dept Urol, Orange, CA 92868 USA
关键词
CAMERA SYSTEMS; SURGERY; 2-D;
D O I
10.1089/end.2013.0344
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Recent technological advancements have led to the introduction of new three-dimensional (3D) cameras in laparoscopic surgery. The 3D view has been touted as useful during robotic surgery, however, there has been limited investigation into the utility of 3D in laparoscopy. Materials and Methods: We performed a prospective, randomized crossover trial comparing a 0 degrees 3D camera with a conventional 0 degrees two-dimensional (2D) camera using a high definition monitor (Karl Storz, Tuttlingen, Germany). All participants completed six standardized basic skills tasks. Quality testing scores were measured by the number of drops, grasping attempts, and precision of needle entry and exiting. Additionally, resolution, color distribution, depth of field and distortion were measured using optical test targets. Results: In this pilot study, we evaluated 10 medical students, 7 residents, and 7 expert surgeons. There was a significant difference in the performance in all the six skill tasks, for the three levels of surgical expertise and training levels in 2D vs 3D except for the cut the line quality score and the peg transfer quality score. Adjusting for the training level, 3D camera image results were superior for the number of rings left (p=0.041), ring transfer quality score (p=0.046), thread the rings (no. of rings) (p=0.0004), and thread the rings quality score (p=0.0002). The 3D camera image was also superior for knot tying (quality score) (p=0.004), peg transfer (time in seconds) (p=0.047), peg transfer pegs left (p=0.012), and for peg transfer quality score (p=0.001). The 3D camera system showed significantly less distortion (p=0.0008), a higher depth of field (p=0.0004) compared with the 2D camera system. Conclusion: 3D laparoscopic camera equipment results in a significant improvement in depth perception, spatial location, and precision of surgical performance compared with the conventional 2D camera equipment. With this improved quality of vision, even expert laparoscopic surgeons may benefit from 3D imaging.
引用
收藏
页码:261 / 266
页数:6
相关论文
共 50 条
  • [1] Evaluation of the Impact of Three-Dimensional Vision on Laparoscopic Performance Editorial Comment
    Knoll, Thomas
    JOURNAL OF ENDOUROLOGY, 2014, 28 (02) : 267 - 268
  • [2] Impact of Three-Dimensional Vision in Laparoscopic Training
    Konstantinos Votanopoulos
    F. Charles Brunicardi
    John Thornby
    Charles F. Bellows
    World Journal of Surgery, 2008, 32 : 110 - 118
  • [3] Impact of three-dimensional vision in laparoscopic training
    Votanopoulos, Konstantinos
    Brunicardi, F. Charles
    Thornby, John
    Bellows, Charles F.
    WORLD JOURNAL OF SURGERY, 2008, 32 (01) : 110 - 118
  • [4] The impact of crosstalk on three-dimensional laparoscopic performance and workload
    Sakata, Shinichiro
    Grove, Philip M.
    Watson, Marcus O.
    Stevenson, Andrew R. L.
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2017, 31 (10): : 4044 - 4050
  • [5] The impact of crosstalk on three-dimensional laparoscopic performance and workload
    Shinichiro Sakata
    Philip M. Grove
    Marcus O. Watson
    Andrew R. L. Stevenson
    Surgical Endoscopy, 2017, 31 : 4044 - 4050
  • [6] Impact of three-dimensional vision in laparoscopic partial nephrectomy for renal tumors
    Tokas, Theodoros
    Avgeris, Margaritis
    Leotsakos, Ioannis
    Nagele, Udo
    Goezen, Ali Serdar
    TURKISH JOURNAL OF UROLOGY, 2021, 47 (02): : 144 - 150
  • [7] Evaluation of three different laparoscopic modalities: Robotics versus three-dimensional vision laparoscopy versus standard laparoscopy
    Lagrange, Chad A.
    Clark, Curtis J.
    Gerber, Eric W.
    Strup, Stephen E.
    JOURNAL OF ENDOUROLOGY, 2008, 22 (03) : 511 - 516
  • [8] Three-dimensional vision versus two-dimensional vision on laparoscopic performance of trainee surgeons: a systematic review and meta-analysis
    Restaino, S.
    Scutiero, G.
    Taliento, Cristina
    Poli, A.
    Bernardi, G.
    Arcieri, M.
    Santi, E.
    Fanfani, F.
    Chiantera, V.
    Driul, L.
    Scambia, G.
    Greco, P.
    Vizzielli, G.
    UPDATES IN SURGERY, 2023, 75 (03) : 455 - 470
  • [9] Three-dimensional vision versus two-dimensional vision on laparoscopic performance of trainee surgeons: a systematic review and meta-analysis
    S. Restaino
    G. Scutiero
    Cristina Taliento
    A. Poli
    G. Bernardi
    M. Arcieri
    E. Santi
    F. Fanfani
    V. Chiantera
    L. Driul
    G. Scambia
    P. Greco
    G. Vizzielli
    Updates in Surgery, 2023, 75 : 455 - 470
  • [10] Influence of three-dimensional vision on surgical telemanipulator performance
    V. Falk
    D. Mintz
    J. Grunenfelder
    J.I. Fann
    T.A. Burdon
    Surgical Endoscopy, 2001, 15 : 1282 - 1288