Hemoglobin near-infrared spectroscopy and surface EMG study in muscle ischaemia and fatiguing isometric contraction

被引:0
|
作者
Alfonsi, E
Pavesi, R
Merlo, IM
Gelmetti, A
Zambarbieri, D
Lago, P
Arrigo, A
Reggiani, C
Moglia, A
机构
[1] IRCCS Fdn, Ist Neurol C Mondino, Clin Neurophysiol Unit, I-27100 Pavia, Italy
[2] IRCCS, Policlin San Matteo, Dept Syst & Comp Sci, Pavia, Italy
[3] Univ Pavia, Interdisciplinar Ctr Sport Med, I-27100 Pavia, Italy
[4] Univ Pavia, Dept Human Physiol, I-27100 Pavia, Italy
来源
JOURNAL OF SPORTS MEDICINE AND PHYSICAL FITNESS | 1999年 / 39卷 / 02期
关键词
spectroscopy; near infrared; muscle; skeletal blood supply; myoelectrical signal; electromyography methods;
D O I
暂无
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Background. To assess how muscle ischaemia and isometric fatiguing contraction influence oxygen content in striated muscle. Methods. We simultaneously measured changes in hemoglobin near-infrared (NIR) spectroscopy and in surface EMG before, during, and after muscle ischaemia and ischaemia plus muscle isometric fatiguing contraction, Seventeen healthy male subjects (age range: 19-40 yrs) were examined in our Clinical Neurophysiology Unit. Test I (9 subjects): hemoglobin NIR spectroscopy and stimulated surface EMG were measured for 2 minutes at rest, for 4 minutes during complete ischaemia of tibialis anterior muscle, and for twelve minutes during recovery. Test II (all subjects): hemoglobin NIR spectroscopy and surface EMG were measured for 2 minutes with the subjects performing brief non-fatiguing contractions, for 4 minutes with the subject performing maximal isometric contraction in complete ischaemia, and for twelve minutes during recovery. EMG parameters measured: median density frequency (MDF); muscle fiber conduction velocity (MFCV). NIR spectroscopy parameters measured: percentage of amplitude decrement (%AD) and nadir time (NT) during ischaemia and ischaemic effort; half-recovery time (1/2 RT) from ischaemia effort. Results. At EMG, we observed a significant shift towards lower values of both MFCV and MDF during fatiguing isometric contraction, MDF recovery was faster then MFCV recovery. At NIR spectroscopy, the 1/2 RT slowed a fast pattern in twelve subjects and a slow pattern in five. 4 significant relationship was found between AD% and 1/2 RT values of test I and AD% and 1/2 values of test II, We found a positive relationship between NT and 1/2 RT in test II, Conclusions, Surface EMG and hemoglobin NIR spectroscopy can be applied simultaneously to evaluate both fatigue intensity and blood flow changes in striated muscle.
引用
收藏
页码:83 / 92
页数:10
相关论文
共 50 条
  • [11] Determination of aerobic–anaerobic transition in the working muscle using EMG and near-infrared spectroscopy data
    Kuznetsov S.Y.
    Popov D.V.
    Borovik A.S.
    Vinogradova O.L.
    Human Physiology, 2015, 41 (5) : 548 - 552
  • [12] Muscle Near-Infrared Spectroscopy Signals versus Venous Blood Hemoglobin Oxygen Saturation in Skeletal Muscle
    Sun, Yi
    Ferguson, Brian S.
    Rogatzki, Mmatthew J.
    Mcdonald, James R.
    Gladden, L. Bruce
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2016, 48 (10): : 2013 - 2020
  • [13] Near-infrared spectroscopy for monitoring muscle oxygenation
    Boushel, R
    Piantadosi, CA
    ACTA PHYSIOLOGICA SCANDINAVICA, 2000, 168 (04): : 615 - 622
  • [14] Effect of Blood Flow on Hemoglobin and Myoglobin Oxygenation in Contracting Muscle Using Near-Infrared Spectroscopy
    Koirala, B.
    Saidel, G. M.
    Hernandez, A.
    Gladden, L. B.
    Lai, N.
    OXYGEN TRANSPORT TO TISSUE XLII, 2021, 1269 : 367 - 372
  • [15] Comparison of forearm muscle oxygenation dynamics during isometric and isotonic contractions monitored by near-infrared spectroscopy
    Cheung, A.
    Tu, L.
    Sahragard, F.
    Shadgan, B.
    BIOPHOTONICS IN EXERCISE SCIENCE, SPORTS MEDICINE, HEALTH MONITORING TECHNOLOGIES, AND WEARABLES, 2020, 11237
  • [16] Muscle fatigue investigation studies using near-infrared spectroscopy and surface electromyography
    Sayli, Omer
    Bicer, Bilal
    Uzun, Selda
    Pelvan, Orkun
    Akin, Ata
    Cotuk, Birol
    CLINICAL AND EXPERIMENTAL HEALTH SCIENCES, 2011, 1 (01): : 17 - 25
  • [17] Vastus Lateralis Muscle Oxygenation Measured By Near-infrared Spectroscopy During Voluntary Isometric Leg Extension Muscle Actions
    Shoemaker, Marni E.
    Gillen, Zachary M.
    Bohannon, Nicholas A.
    Gibson, Sydney M.
    Cramer, Joel T.
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2020, 52 (07) : 154 - 155
  • [18] Near-infrared Spectroscopy System for Determining Brain Hemoglobin Level
    Wu, Pei-Jung
    Chang, Ming-Hsien
    Huang, Cheng-Yang
    Wang, Yu-Cheng
    Kuo, Jinn-Rung
    Huang, Yan-Jun
    Lin, Bor-Shyh
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 2412 - 2414
  • [19] QUANTITATIVE DETECTION OF HEMOGLOBIN SATURATION IN THE LIVER WITH NEAR-INFRARED SPECTROSCOPY
    KITAI, T
    TANAKA, A
    TOKUKA, A
    TANAKA, K
    YAMAOKA, Y
    OZAWA, K
    HIRAO, K
    HEPATOLOGY, 1993, 18 (04) : 926 - 936
  • [20] Accurary of Oxygen Desaturation of Hemoglobin in Muscle by Near-Infrared Oximeters
    Quaresima, Valentina
    Ferrari, Marco
    Fantini, Sergio
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2013, 45 (06): : 1217 - 1217