Characterization of a novel phantom for three-dimensional in vitro cell experiments

被引:5
|
作者
Altman, Michael B. [1 ]
Vesper, Benjamin J. [2 ,3 ]
Smith, Brett D. [4 ]
Stinauer, Michelle A. [4 ]
Pelizzari, Charles A. [1 ]
Aydogan, Bulent [1 ,4 ]
Reft, Chester S. [1 ]
Radosevich, James A. [2 ,3 ]
Chmura, Steven J. [1 ]
Roeske, John C. [5 ]
机构
[1] Univ Chicago, Dept Radiat & Cellular Oncol, Chicago, IL 60637 USA
[2] Univ Illinois, Coll Dent, Ctr Mol Biol Oral Dis, Chicago, IL USA
[3] Jesse Brown VAMC, Chicago, IL USA
[4] Univ Illinois, Dept Radiat Oncol, Chicago, IL USA
[5] Loyola Univ, Med Ctr, Dept Radiat Oncol, Maywood, IL 60153 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2009年 / 54卷 / 05期
关键词
INTENSITY-MODULATED RADIOTHERAPY; RADIATION-THERAPY; BEAM DOSIMETRY; VERIFICATION; PHOTON; FILM; SENSITIVITY; IRRADIATION; ALGORITHM; PATTERN;
D O I
10.1088/0031-9155/54/5/N02
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A novel intensity-modulated radiation therapy (IMRT) phantom for use in three-dimensional in vitro cell experiments, based on a commercially available system (CIRS Inc., Norfolk, VA), was designed and fabricated. The water-equivalent plastic phantom can, with a set of water-equivalent plastic inserts, enclose 1-3 multi-well tissue culture plates. Dosimetry within the phantom was assessed using thermoluminescence dosimeters (TLDs) and film. The phantom was loaded with three tissue culture plates, and an array of TLDs or a set of three films was placed underneath each plate within the phantom, and then irradiated using an IMRT plan created for it. Measured doses from each dosimeter were compared to those acquired from the treatment planning system. The percent differences between TLD measurements and the corresponding points in the treatment plan ranged from 1.3% to 2.9%, differences which did not show statistical significance. Average point-by-point percent dose differences for each film plane ranged from 1.6% to 3.1%. The percentage dose difference for which 95% of the points in the film matched those corresponding to the calculated dose plane to within 3.0% ranged from 2.8% to 4.2%. The good agreement between predicted and measured dose shows that the phantom is a useful and efficient tool for three-dimensional in vitro cell experiments.
引用
收藏
页码:N75 / N82
页数:8
相关论文
共 50 条
  • [41] A novel tissue engineered three-dimensional in vitro colorectal cancer model
    Nyga, Agata
    Loizidou, Marilena
    Emberton, Mark
    Cheema, Umber
    ACTA BIOMATERIALIA, 2013, 9 (08) : 7917 - 7926
  • [42] Development of a novel three-dimensional in vitro model of oral Candida infection
    Dongari-Bagtzoglou, A.
    Kashleva, H.
    MICROBIAL PATHOGENESIS, 2006, 40 (06) : 271 - 278
  • [43] Novel use of a three-dimensional in vitro environment; does flexor and extensor tendon cell behavior differ?
    Stanley, Rachael Louise
    Carolin, Amy Miriam
    Agabalyan, Natasha Anahid
    Evans, Darrell John Rhys
    FASEB JOURNAL, 2013, 27
  • [44] Three-dimensional characterization of skyrmions
    Silvia Conti
    Nature Reviews Electrical Engineering, 2024, 1 (11): : 698 - 698
  • [45] Design and construction of a customizable phantom for the characterization of the three-dimensional magnetic resonance imaging geometric distortion
    Torfeh, Tarraf
    Hammoud, Rabih
    Paloor, Satheesh
    Arunachalam, Yoganathan
    Aouadi, Souha
    Al-Hammadi, Noora
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (12): : 149 - 157
  • [46] Three-dimensional In Vitro Model of Breast Cancer: Toward Replacing the Need for Animal Experiments
    Holliday, Deborah L.
    ATLA-ALTERNATIVES TO LABORATORY ANIMALS, 2010, 38 : 41 - 44
  • [47] Ultrasonically determined thickness of long cortical bones:: Three-dimensional simulations of in vitro experiments
    Moilanen, Petro
    Talmant, Maryline
    Nicholson, Patrick H. F.
    Cheng, Sulin
    Timonen, Jussi
    Laugier, Pascal
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2007, 122 (04): : 2439 - 2445
  • [48] Ultrasonically determined thickness of long cortical bones: Three-dimensional simulations of in vitro experiments
    Moilanen, Petro
    Talmant, Maryline
    Nicholson, Patrick H. F.
    Cheng, Sulin
    Timonen, Jussi
    Laugier, Pascal
    Journal of the Acoustical Society of America, 2007, 122 (04): : 2439 - 2445
  • [49] A Novel Three-Dimensional Microheater
    Xu, Lei
    Li, Tie
    Wang, Yuelin
    IEEE ELECTRON DEVICE LETTERS, 2011, 32 (09) : 1284 - 1286
  • [50] Feasibility of Novel Three-Dimensional Magnetic Resonance Fingerprinting of the Prostate Gland: Phantom and Clinical Studies
    Han, Dongyeob
    Choi, Moon Hyung
    Lee, Young Joon
    Kim, Dong Hyun
    KOREAN JOURNAL OF RADIOLOGY, 2021, 22 (08) : 1332 - 1340