Stir bar sorptive extraction coupled to liquid chromatography-tandem mass spectrometry for the determination of pesticides in water samples: Method validation and measurement uncertainty

被引:59
|
作者
Margoum, Christelle [1 ]
Guillemain, Celine [1 ]
Yang, Xi [1 ,2 ]
Coquery, Marina [1 ]
机构
[1] Irstea, UR MALY, F-69626 Villeurbanne, France
[2] Nanjing Univ, State Key Lab Pollut Control & Resource Reuse, Nanjing 210093, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
Stir bar sorptive extraction (SBSE); Liquid chromatography-tandem mass spectrometry (LC-MSMS); Pesticides; Surface water; Validation; Measurement uncertainty; POLYCYCLIC AROMATIC-HYDROCARBONS; PRIORITY SEMIVOLATILE COMPOUNDS; CAPILLARY GAS-CHROMATOGRAPHY; EXPERIMENTAL-DESIGN; METHOD OPTIMIZATION; MATRICES;
D O I
10.1016/j.talanta.2013.04.066
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Stir bar sorptive extraction followed by liquid desorption and high performance liquid chromatography with tandem mass spectrometry (SBSE-LD-LC-MSMS) has been developed for the determination of 15 pesticides or selected metabolites from different families (herbicides, insecticides, fungicides) in surface water samples. The optimization of parameters that could influence SBSE-LD efficiency was carried out by means of experimental design. Optimized conditions were established as follows concerning extraction time, stirring speed, aqueous medium characteristics (ionic strength and polarity) and back desorption solvent and time, respectively: 3 h (800 rpm), addition of 10% of sodium chloride, no addition of methanol as organic modifier, and 15 mm ultrasonic desorption in equivolume mixtures of acetonitrile-methanol. A specific and thorough cleanup procedure was developed and applied to each stir bar to avoid possible carry-over between consecutive extractions with the same stir bar. Pesticide quantification in water was achieved thanks to matrix matched calibration. Mean recoveries ranged from 93 to 101% (RSD <17%, n=30). Validated limits of quantification in matrix were between 0.02 and 1 mu g L-1, depending on the compound. A specific experimental design was conducted to evaluate the measurement uncertainty, which was comprised between 13 and 51%, whatever the pesticide and the concentration level. The applicability of the SBSE-LD-LCMSMS method was evaluated by analyzing surface water samples and by comparing with conventional solid phase extraction-LC-MSMS procedure. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 7
页数:7
相关论文
共 50 条
  • [41] Determination of kepone in water by liquid chromatography-tandem mass spectrometry
    Zhou Li
    Dong Liang
    Shi Shuangxin
    Zhang Lifei
    Zhang Xiulan
    Yang Wenlong
    Li Lingling
    Huang Yeru
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2014, 32 (03) : 211 - 215
  • [42] Simultaneous Determination of Seven Preservatives in Beverage and Jam Using Stir Bar Sorptive Extraction and Gas Chromatography-Tandem Mass Spetrometry
    Chen Qi
    Ling Yun
    Zhang Feng
    Huang Jun-Rong
    Chu Xiao-Gang
    Wu Yong-Ning
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 38 (08) : 1156 - 1160
  • [43] Green and sensitive method combining ultrasonic solvent extraction, stir bar sorptive extraction and thermal desorption-gas chromatography-tandem mass spectrometry for determination of organotin compounds in sediment
    Nagyova, Slavka
    Tolgyessy, Peter
    Hrouzkova, Svetlana
    MICROCHEMICAL JOURNAL, 2024, 207
  • [44] Continental bottled water assessment by stir bar sorptive extraction followed by gas chromatography-tandem mass spectrometry (SBSE-GC-MS/MS)
    Albert Guart
    Ignacio Calabuig
    Silvia Lacorte
    Antonio Borrell
    Environmental Science and Pollution Research, 2014, 21 : 2846 - 2855
  • [45] Continental bottled water assessment by stir bar sorptive extraction followed by gas chromatography-tandem mass spectrometry (SBSE-GC-MS/MS)
    Guart, Albert
    Calabuig, Ignacio
    Lacorte, Silvia
    Borrell, Antonio
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2014, 21 (04) : 2846 - 2855
  • [46] Determination of neonicotinoid pesticides residues in agricultural samples by solid-phase extraction combined with liquid chromatography-tandem mass spectrometry
    Xie, Wen
    Han, Chao
    Qian, Yan
    Ding, Huiying
    Chen, Xiaomei
    Xi, Junyang
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (28) : 4426 - 4433
  • [47] Development of a method for the determination of UV filters in water samples using stir bar sorptive extraction and thermal desorption-gas chromatography-mass spectrometry
    Rodil, Rosario
    Moeder, Monika
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1179 (02) : 81 - 88
  • [48] Determination of corticosteroids in tissue samples by liquid chromatography-tandem mass spectrometry
    Rönquist-Nii, Y
    Edlund, PO
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 37 (02) : 341 - 350
  • [49] Indacaterol Determination in Human Urine: Validation of a Liquid-Liquid Extraction and Liquid Chromatography-Tandem Mass Spectrometry Analytical Method
    Ammari, Wesam G.
    Al-Qadhi, Zainab
    Khalil, Mohammad
    Tayyem, Rabab
    Qammaz, Samir
    Oriquat, Ghaleb
    Basheti, Iman A.
    Chrystyn, Henry
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2015, 28 (03) : 202 - 210
  • [50] DETERMINATION OF DIETHYLSTILBESTROL IN HUMAN PLASMA WITH MEASUREMENT UNCERTAINTY ESTIMATION BY LIQUID CHROMATOGRAPHY-TANDEM MASS SPECTROMETRY
    Liu, Yi
    Li, Na
    Ma, Liping
    Huang, Lin
    Jing, Shan
    Zhao, Libo
    Feng, Wanyu
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2014, 37 (03) : 353 - 366