CT-guided Transthoracic Needle Biopsy in the Diagnosis of Sarcoidosis

被引:14
|
作者
Klein, Jeffrey S. [1 ,3 ]
Johnson, Alisa [1 ,3 ]
Watson, Elizabeth [3 ]
Mount, Sharon [2 ,3 ]
机构
[1] Fletcher Allen Hlth Care, Dept Radiol, Burlington, VT 05401 USA
[2] Fletcher Allen Hlth Care, Dept Pathol & Lab Med, Burlington, VT 05401 USA
[3] Univ Vermont, Coll Med, Burlington, VT USA
关键词
computed tomography; transthoracic needle biopsy; automated core tissue biopsy; sarcoidosis; noncascating granulomas; MEDIASTINAL LYMPH-NODES; ENDOBRONCHIAL ULTRASOUND; ENDOSCOPIC ULTRASOUND; ASPIRATION; LESIONS; LUNG;
D O I
10.1097/RTI.0b013e31818d12c2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: In patients with suspected sarcoidosis requiring pathologic confirmation of the presence of noncascating granulomatous inflammation and the exclusion of alternative disorders, bronchoscopic transbronchial lung biopsy and more recently transbronchial needle,aspiration of mediastinal lymph nodes have been the standard biopsy procedures in most cases. We describe our experience with computed tomography-guided transthoracic needle biopsy (CT-TNB) of mediastinal lymph nodes for the diagnosis of sarcoidosis. Materials. and Methods: We retrospectively reviewed our single institution experience with coaxial CT=TNB of enlarged mediastinal lymph nodes in the diagnosis of sarcoidosis. Forty-one biopsies were performed in 40 patients over a 10-year period from 1997 to 2007. Viral pathologic diagnosis was obtained from record review. The type of biopsy performed (aspiration cytology, core needle biopsy for histology, or both) was recorded. The method of needle approach used was obtained from review of images obtained during biopsy and the radiology report. Complications including pneumothorax, bleeding, and need for chest tube insertion for pneumothorax drainage were recorded. Yield of cytologic versus histologic,- diagnosis of sarcoidosis was compared using a Fisher exact test. Results: Overall diagnostic yield was 93%, with core needle biopsy having a significantly higher yield as compared with fine needle aspiration cytology (96% vs. 78%, P < 0.05). Pneumothorax developed in 22%, with 5% requiring overnight catheter drainage. Conclusions: CT-TNB is a safe and accurate technique in the pathologic diagnosis of sarcoidosis, particularly when core tissue specimens are obtained.
引用
收藏
页码:23 / 30
页数:8
相关论文
共 50 条
  • [41] Feasibility of CT-guided percutaneous needle biopsy in early diagnosis of BOOP
    Poulou, Loukia S.
    Tsangaridou, Iris
    Filippoussis, Petros
    Sidiropoulou, Nektaria
    Apostolopoulou, Sofia
    Thanos, Loukas
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2008, 31 (05) : 1003 - 1007
  • [42] CT-guided core-needle biopsy in the diagnosis of mediastinal lymphoma
    Sklair-Levy, M
    Polliack, A
    Shaham, D
    Applbaum, YH
    Gillis, S
    Ben-Yehuda, D
    Sherman, Y
    Libson, E
    EUROPEAN RADIOLOGY, 2000, 10 (05) : 714 - 718
  • [43] CT-guided fine needle aspiration biopsy in the diagnosis of lung cancer
    Tavernaraki, A
    Alexiu, T
    Andriotis, E
    Deliveliotis, K
    Koronis, V
    Sigalas, A
    Raptis, K
    Dahabre, T
    2ND INTERNATIONAL CONGRESS ON LUNG CANCER, 1996, : 139 - 143
  • [44] CT-guided core-needle biopsy in the diagnosis of mediastinal lymphoma
    M. Sklair-Levy
    A. Polliack
    D. Shaham
    Y. H. Applbaum
    S. Gillis
    D. Ben-Yehuda
    Y. Sherman
    E. Libson
    European Radiology, 2000, 10 : 714 - 718
  • [45] Clinical application of CT and CT-guided percutaneous transthoracic needle biopsy in patients with indeterminate pulmonary nodules
    Cardoso, Luciana Vargas
    Souza Junior, Arthur Soares
    JORNAL BRASILEIRO DE PNEUMOLOGIA, 2014, 40 (04) : 380 - 388
  • [46] Comparison of cone-beam CT-guided and CT fluoroscopy-guided transthoracic needle biopsy of lung nodules
    Nicola Rotolo
    Chiara Floridi
    Andrea Imperatori
    Federico Fontana
    Anna Maria Ierardi
    Monica Mangini
    Veronica Arlant
    Giuseppe De Marchi
    Raffaele Novario
    Lorenzo Dominioni
    Carlo Fugazzola
    Gianpaolo Carrafiello
    European Radiology, 2016, 26 : 381 - 389
  • [47] Comparison of cone-beam CT-guided and CT fluoroscopy-guided transthoracic needle biopsy of lung nodules
    Rotolo, Nicola
    Floridi, Chiara
    Imperatori, Andrea
    Fontana, Federico
    Ierardi, Anna Maria
    Mangini, Monica
    Arlant, Veronica
    De Marchi, Giuseppe
    Novario, Raffaele
    Dominioni, Lorenzo
    Fugazzola, Carlo
    Carrafiello, Gianpaolo
    EUROPEAN RADIOLOGY, 2016, 26 (02) : 381 - 389
  • [48] CT-guided needle biopsy for musculoskeletal lesions
    Satoshi Tsukushi
    Yoshihiro Nishida
    Yoshihisa Yamada
    Masahiro Yoshida
    Naoki Ishiguro
    Archives of Orthopaedic and Trauma Surgery, 2010, 130 : 699 - 703
  • [49] CT-GUIDED NEEDLE-BIOPSY - REPLY
    GUMERLOCK, MK
    GOLDSTEIN, S
    NEUWELT, EA
    JOURNAL OF NEUROSURGERY, 1988, 68 (04) : 656 - 657
  • [50] CT-GUIDED NEEDLE-BIOPSY OF THE PANCREAS
    PINTO, MM
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 1993, 88 (06): : 967 - 967