Diagnostic developments for quasicontinuous operation of the Wendelstein 7-X stellarator

被引:5
|
作者
Koenig, R. [1 ]
Cantarini, J. [1 ]
Dreier, H. [1 ]
Erckmann, V. [1 ]
Hildebrandt, D. [1 ]
Hirsch, M. [1 ]
Kocsis, G. [2 ]
Kornejew, P. [1 ]
Laux, M. [1 ]
Laqua, H. [1 ]
Pasch, E. [1 ]
Recsei, S. [2 ]
Szabo, V. [3 ]
Thomsen, H. [1 ]
Weller, A. [1 ]
Werner, A. [1 ]
Wolf, R. [1 ]
Ye, M. Y. [1 ]
Zoletnik, S. [2 ]
机构
[1] Max Planck Inst Plasma Phys, EURATOM Assoc, D-17491 Greifswald, Germany
[2] KFKI Res Inst Particle & Nucl Phys, EURATOM Assoc, H-1121 Budapest, Hungary
[3] Budapest Univ Technol & Econ, EURATOM Assoc, Dept Appl Mech, H-1521 Budapest, Hungary
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2008年 / 79卷 / 10期
关键词
discharges (electric); plasma diagnostics; stellarators;
D O I
10.1063/1.2964998
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The stellarator Wendelstein 7-X will allow for quasicontinuous operation with the duration only being limited to two 30 min discharges per day, at a continuous heating power of 10 MW electron cyclotron resonance heating (ECRH) at 140 GHz, by the capacity of the cooling water reservoir. This will result in high thermal loads on all plasma facing components of 50-100 kW/m(2) from radiation alone and of up to about 500 kW/m(2) on components additionally exposed to convective loads. In high density scenarios toroidally varying ECRH stray radiation levels of 50-200 kW/m(2) need to be coped with, requiring careful material selection and different shielding and hardening techniques. Furthermore, a gradual buildup of coatings on plasma facing optical components, which without any measures being taken, would lead to high transmission losses already within a few days of long pulse operation (equivalent to about 1 year of operation in pulsed devices like JET or ASDEX-upgrade) and therefore needs to be prevented as much as possible. In addition in situ cleaning as well as absolute calibration techniques need to be developed for all plasma facing optical systems. Here we report about some of our efforts to find, for various types of diagnostics, ways to cope with these adverse effects. Moreover, we give a few examples for individual diagnostic specific issues with respect to quasicontinuous operation, such as the development of a special integrator for the magnetic diagnostics as well as special interferometer types which can cope with unavoidable vibrations and slow path length changes due to, e.g., thermal expansion of the plasma vessel.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Experience with the commissioning of the superconducting stellarator Wendelstein 7-X
    Bosch, Hans-Stephan
    Bykov, V.
    Brakel, R.
    van Eeten, P.
    Feist, J. -H.
    Gasparotto, M.
    Grote, H.
    Klinger, T.
    Nagel, M.
    Naujoks, D.
    Neilson, G. H.
    Rummel, T.
    Schacht, J.
    Vilbrandt, R.
    Wegener, L.
    Werner, A.
    FUSION ENGINEERING AND DESIGN, 2015, 96-97 : 22 - 27
  • [22] The Superconducting Magnet System of the Stellarator Wendelstein 7-X
    Rummel, Thomas
    Risse, Konrad
    Ehrke, Gunnar
    Rummel, Kerstin
    John, Andre
    Moennich, Thomas
    Buscher, Klaus-Peter
    Fietz, Walter H.
    Heller, Reinhard
    Neubauer, Olaf
    Panin, Anatoly
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2012, 40 (03) : 769 - 776
  • [23] The superconducting magnet system for the Wendelstein 7-X Stellarator
    Sapper, J
    FUSION TECHNOLOGY, 1996, 30 (03): : 1234 - 1240
  • [24] The superconducting magnet system of the stellarator Wendelstein 7-X
    Rummel, Thomas
    Risse, Konrad
    Ehrke, Gunnar
    Rummel, Kerstin
    John, Andre
    Moennich, Thomas
    Buscher, Klaus-Peter
    Fietz, Walter
    Heller, Reinhard
    Neubauer, Olaf
    Panin, Anatoly
    2011 IEEE/NPSS 24TH SYMPOSIUM ON FUSION ENGINEERING (SOFE), 2011,
  • [25] Magnetic configuration effects on the Wendelstein 7-X stellarator
    A. Dinklage
    C. D. Beidler
    P. Helander
    G. Fuchert
    H. Maaßberg
    K. Rahbarnia
    T. Sunn Pedersen
    Y. Turkin
    R. C. Wolf
    A. Alonso
    T. Andreeva
    B. Blackwell
    S. Bozhenkov
    B. Buttenschön
    A. Czarnecka
    F. Effenberg
    Y. Feng
    J. Geiger
    M. Hirsch
    U. Höfel
    M. Jakubowski
    T. Klinger
    J. Knauer
    G. Kocsis
    A. Krämer-Flecken
    M. Kubkowska
    A. Langenberg
    H. P. Laqua
    N. Marushchenko
    A. Mollén
    U. Neuner
    H. Niemann
    E. Pasch
    N. Pablant
    L. Rudischhauser
    H. M. Smith
    O. Schmitz
    T. Stange
    T. Szepesi
    G. Weir
    T. Windisch
    G. A. Wurden
    D. Zhang
    Nature Physics, 2018, 14 : 855 - 860
  • [26] Proposed neutron diagnostics for Wendelstein 7-X stellarator
    Elevant, T.
    Wolle, B.
    Weller, A.
    Review of Scientific Instruments, 1999, 70 (1 pt 2):
  • [27] The Dedicated ICRH System for the Stellarator Wendelstein 7-X
    Ongena, J.
    Messiaen, A.
    Dumortier, P.
    Durodie, F.
    Kazakov, Ye O.
    Louche, F.
    Schweer, B.
    Vervier, M.
    Van Eester, D.
    Koch, R.
    Krivska, A.
    Lyssoivan, A.
    Van Schoor, M.
    Wauters, T.
    Borsuk, V.
    Neubauer, O.
    Schmitz, O.
    Offermans, G.
    Altenburg, Y.
    Baylard, C.
    Birus, D.
    Bozhenkov, S.
    Hartmann, D. A.
    Kallmeyer, J.
    Renard, S.
    Wolf, R.
    RADIOFREQUENCY POWER IN PLASMAS, 2014, 1580 : 105 - 112
  • [28] Modular stellarator reactors and plans for Wendelstein 7-X
    Grieger, G.
    Beidler, C.
    Harmeyer, E.
    Lotz, W.
    Kisslinger, J.
    Merkel, P.
    Nuhrenberg, J.
    Rau, F.
    Strumberger, E.
    Wobig, H.
    Fusion Technology, 1992, 21 (3 pt 2B): : 1767 - 1778
  • [29] SUPERCONDUCTOR FOR THE COILS OF THE MODULAR STELLARATOR WENDELSTEIN 7-X
    HELLER, R
    IEEE TRANSACTIONS ON MAGNETICS, 1994, 30 (04) : 2383 - 2386
  • [30] Proposed neutron diagnostics for Wendelstein 7-X stellarator
    Elevant, T
    Wolle, B
    Weller, A
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (01): : 1185 - 1189