Diagnostic developments for quasicontinuous operation of the Wendelstein 7-X stellarator

被引:5
|
作者
Koenig, R. [1 ]
Cantarini, J. [1 ]
Dreier, H. [1 ]
Erckmann, V. [1 ]
Hildebrandt, D. [1 ]
Hirsch, M. [1 ]
Kocsis, G. [2 ]
Kornejew, P. [1 ]
Laux, M. [1 ]
Laqua, H. [1 ]
Pasch, E. [1 ]
Recsei, S. [2 ]
Szabo, V. [3 ]
Thomsen, H. [1 ]
Weller, A. [1 ]
Werner, A. [1 ]
Wolf, R. [1 ]
Ye, M. Y. [1 ]
Zoletnik, S. [2 ]
机构
[1] Max Planck Inst Plasma Phys, EURATOM Assoc, D-17491 Greifswald, Germany
[2] KFKI Res Inst Particle & Nucl Phys, EURATOM Assoc, H-1121 Budapest, Hungary
[3] Budapest Univ Technol & Econ, EURATOM Assoc, Dept Appl Mech, H-1521 Budapest, Hungary
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2008年 / 79卷 / 10期
关键词
discharges (electric); plasma diagnostics; stellarators;
D O I
10.1063/1.2964998
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The stellarator Wendelstein 7-X will allow for quasicontinuous operation with the duration only being limited to two 30 min discharges per day, at a continuous heating power of 10 MW electron cyclotron resonance heating (ECRH) at 140 GHz, by the capacity of the cooling water reservoir. This will result in high thermal loads on all plasma facing components of 50-100 kW/m(2) from radiation alone and of up to about 500 kW/m(2) on components additionally exposed to convective loads. In high density scenarios toroidally varying ECRH stray radiation levels of 50-200 kW/m(2) need to be coped with, requiring careful material selection and different shielding and hardening techniques. Furthermore, a gradual buildup of coatings on plasma facing optical components, which without any measures being taken, would lead to high transmission losses already within a few days of long pulse operation (equivalent to about 1 year of operation in pulsed devices like JET or ASDEX-upgrade) and therefore needs to be prevented as much as possible. In addition in situ cleaning as well as absolute calibration techniques need to be developed for all plasma facing optical systems. Here we report about some of our efforts to find, for various types of diagnostics, ways to cope with these adverse effects. Moreover, we give a few examples for individual diagnostic specific issues with respect to quasicontinuous operation, such as the development of a special integrator for the magnetic diagnostics as well as special interferometer types which can cope with unavoidable vibrations and slow path length changes due to, e.g., thermal expansion of the plasma vessel.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] The magnet system of Wendelstein 7-X stellarator in operation
    Risse, Konrad
    Rummel, Thomas
    Bosch, Hans-Stephan
    Bykov, Victor
    Carls, Andre
    Fuellenbach, Frank
    Moennich, Thomas
    Nagel, Michael
    FUSION ENGINEERING AND DESIGN, 2018, 136 : 12 - 16
  • [2] The Wendelstein 7-X Stellarator
    Wagner, F
    Milch, I
    ATW-INTERNATIONAL JOURNAL FOR NUCLEAR POWER, 2005, 50 (8-9): : 519 - +
  • [3] Fast ion loss diagnostic for the Wendelstein 7-X stellarator
    Werner, A
    Darrow, DS
    Kuduk, R
    Weller, A
    ADVANCED DIAGNOSTICS FOR MAGNETIC AND INERTIAL FUSION, 2002, : 137 - 140
  • [4] Commissioning and first operation of the pulse-height analysis diagnostic on Wendelstein 7-X stellarator
    Krawczyk, Natalia
    Biedermann, Christoph
    Czarnecka, Agata
    Fornal, Tomasz
    Jablonski, Slawomir
    Kaczmarczyk, Jacek
    Kubkowska, Monika
    Kunkel, Falk
    McCarthy, Kieran J.
    Ryc, Leszek
    Thomsen, Henning
    Weller, Arthur
    FUSION ENGINEERING AND DESIGN, 2017, 123 : 1006 - 1010
  • [5] The Set of Diagnostics for the First Operation Campaign of the Wendelstein 7-X Stellarator
    Koenig, Ralf
    Baldzuhn, J.
    Biel, W.
    Biedermann, C.
    Bosch, H. S.
    Bozhenkov, S.
    Braeuer, T.
    Brotas de Carvalho, B.
    Burhenn, R.
    Buttenschoen, B.
    Cseh, G.
    Czarnecka, A.
    Endler, M.
    Erckmann, V.
    Estrada, T.
    Geiger, J.
    Grulke, O.
    Hartmann, D.
    Hathiramani, D.
    Hirsch, M.
    Onski, S. Jabl
    Jakubowski, M.
    Kaczmarczyk, J.
    Klinger, T.
    Klose, S.
    Kocsis, G.
    Kornejew, P.
    Kraemer-Flecken, A.
    Kremeyer, T.
    Krychowiak, M.
    Kubkowska, M.
    Langenberg, A.
    Laqua, H. P.
    Laux, M.
    Liang, Y.
    Lorenz, A.
    Marchuk, A. O.
    Moncada, V.
    Neubauer, O.
    Neuner, U.
    Oosterbeek, J. W.
    Otte, M.
    Pablant, N.
    Pasch, E.
    Pedersen, T. S.
    Rahbarnia, K.
    Ryc, L.
    Schmitz, O.
    Schneider, W.
    Schuhmacher, H.
    JOURNAL OF INSTRUMENTATION, 2015, 10
  • [6] Final integration, commissioning and start of the Wendelstein 7-X stellarator operation
    Bosch, H. -S.
    Brakel, R.
    Braeuer, T.
    Bykov, V.
    van Eeten, P.
    Feist, J. -H.
    Fuellenbach, F.
    Gasparotto, M.
    Grote, H.
    Klinger, T.
    Laqua, H.
    Nagel, M.
    Naujoks, D.
    Otte, M.
    Risse, K.
    Rummel, T.
    Schacht, J.
    Spring, A.
    Pedersen, T. Sunn
    Vilbrandt, R.
    Wegener, L.
    Werner, A.
    Wolf, R. C.
    Baldzuhn, J.
    Biedermann, C.
    Braune, H.
    Burhenn, R.
    Hirsch, M.
    Hoefl, U.
    Knauer, J.
    Kornejew, P.
    Marsen, S.
    Stange, T.
    Mora, H. Trimino
    NUCLEAR FUSION, 2017, 57 (11)
  • [7] Transition from Construction to Operation Phase of the Wendelstein 7-X Stellarator
    Bosch, Hans-Stephan
    Brakel, Rudolf
    Gasparotto, Maurizio
    Grote, Heinz
    Hartmann, Dirk A.
    Herrmann, Rene
    Nagel, Michael
    Naujoks, Dirk
    Otte, Matthias
    Risse, Konrad
    Rummel, Thomas
    Werner, Andreas
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2014, 42 (03) : 432 - 438
  • [8] Aspects of steady-state operation of the Wendelstein 7-X stellarator
    Geiger, J.
    Wolf, R. C.
    Beidler, C.
    Cardella, A.
    Chlechowitz, E.
    Erckmann, V.
    Gantenbein, G.
    Hathiramani, D.
    Hirsch, M.
    Kasparek, W.
    Kisslinger, J.
    Koenig, R.
    Kornejew, P.
    Laqua, H. P.
    Lechte, C.
    Lore, J.
    Lumsdaine, A.
    Maassberg, H.
    Marushchenko, N. B.
    Michel, G.
    Otte, M.
    Peacock, A.
    Pedersen, T. Sunn
    Thumm, M.
    Turkin, Y.
    Werner, A.
    Zhang, D.
    PLASMA PHYSICS AND CONTROLLED FUSION, 2013, 55 (01)
  • [9] Diagnostics Development for Steady State Operation of the Stellarator Wendelstein 7-X
    Burhenn, R.
    Baldzuhn, J.
    Biel, W.
    Dreier, H.
    Endler, M.
    Jimenez-Gomez, R.
    Grosser, K.
    Hartfuss, H. J.
    Hildebrandt, D.
    Hirsch, M.
    Koenig, R.
    Kornejew, P.
    Krychowiak, M.
    Laqua, H. P.
    Laux, M.
    Oosterbeek, J. W.
    Pasch, E.
    Schneider, W.
    Thomsen, H.
    Weller, A.
    Werner, A.
    Wolf, R.
    Zhang, D.
    CONTRIBUTIONS TO PLASMA PHYSICS, 2011, 51 (2-3) : 271 - 278
  • [10] Neutron diagnostics at the Wendelstein 7-X stellarator
    Schneider, W.
    Wiegel, B.
    Gruenauer, F.
    Burhenn, R.
    Koch, S.
    Schuhmacher, H.
    Zimbal, A.
    JOURNAL OF INSTRUMENTATION, 2012, 7