Study of the time reversal symmetry in the decay of ortho-Positronium atoms using the J-PET detector

被引:1
|
作者
Raj, Juhi [1 ]
Silarski, Michal [1 ]
机构
[1] Jagiellonian Univ, Fac Phys Astron & Appl Comp Sci, S Lojasiewicza 11, PL-30348 Krakow, Poland
来源
MESON 2018 - 15TH INTERNATIONAL WORKSHOP ON MESON PHYSICS | 2019年 / 199卷
基金
奥地利科学基金会;
关键词
RECONSTRUCTION; VIOLATION; CPT;
D O I
10.1051/epjconf/201919905015
中图分类号
O412 [相对论、场论]; O572.2 [粒子物理学];
学科分类号
摘要
The Jagiellonian Positron Emission Tomograph (J-PET) is a novel device based on organic scintillators being developed at Jagiellonian University in Krakow, Poland. J-PET is an axially symmetric and high acceptance scanner that can be used as a multi-purpose detector system. It is well suited to pursue tests of discrete symmetries in decays of positronium in addition to medical imaging. J-PET enables measurement of both momenta and polarization vectors of annihilation photons. The latter is a unique feature of the J-PET detector which allows study of the time reversal symmetry violation operator constructed solely from the annihilation photons momenta before and after scattering within the detector.
引用
收藏
页数:3
相关论文
共 45 条
  • [31] POTENTIAL OF THE J-PET DETECTOR FOR STUDIES OF DISCRETE SYMMETRIES IN DECAYS OF POSITRONIUM ATOM - A PURELY LEPTONIC SYSTEM
    Moskal, P.
    Alfs, D.
    Bednarski, T.
    Bialas, P.
    Czerwinski, E.
    Curceanu, C.
    Gajos, A.
    Glowacz, B.
    Gorgol, M.
    Hiesmayr, B. C.
    Jasinska, B.
    Kaminska, D.
    Korcyl, G.
    Kowalski, P.
    Kozik, T.
    Krzemien, W.
    Krawczyk, N.
    Kubicz, E.
    Mohammed, M.
    Niedzwiecki, Sz.
    Pawlik-Niedzwiecka, M.
    Raczynski, L.
    Rudy, Z.
    Silarski, M.
    Wieczorek, A.
    Wislicki, W.
    Zielinski, M.
    ACTA PHYSICA POLONICA B, 2016, 47 (02): : 509 - 535
  • [32] SEARCH FOR THE CHARGE SYMMETRY FORBIDDEN DECAYS OF ELECTRON-POSITRON BOUND STATE USING THE J-PET DETECTOR
    Chhokar, J.
    ACTA PHYSICA POLONICA B, 2020, 51 (01): : 365 - 371
  • [33] Multi-photon time-of-flight MLEM application for the positronium imaging in J-PET
    Shopa, Roman Y.
    Dulski, Kamil
    BIO-ALGORITHMS AND MED-SYSTEMS, 2022, 18 (01) : 135 - 143
  • [34] Reconstruction of hit time and hit position of annihilation quanta in the J-PET detector using the Mahalanobis distance
    Sharma, Neha Gupta
    Silarski, Michal
    Bednarski, Tomasz
    Bialas, Piotr
    Czerwinski, Eryk
    Gajos, Aleksander
    Gorgol, Marek
    Jasinska, Bozena
    Kaminska, Daria
    Kaplon, Lukasz
    Korcyl, Grzegorz
    Kowalski, Pawel
    Kozik, Tomasz
    Krzemien, Wojciech
    Kubicz, Ewelina
    Niedzwiecki, Szymon
    Palka, Marek
    Raczynski, Lech
    Rudy, Zbigniew
    Rundel, Oleksandr
    Slomski, Artur
    Strzelecki, Adam
    Wieczorek, Anna
    Wislicki, Wojciech
    Zielinski, Marcin
    Zgardzinska, Bozena
    Moskal, Pawel
    NUKLEONIKA, 2015, 60 (04) : 765 - 769
  • [35] Optimization of positronium imaging performance of a simulated modular J-PET scanner using GATE software
    Parzych, Szymon
    BIO-ALGORITHMS AND MED-SYSTEMS, 2023, 19 (01) : 80 - 86
  • [36] Multiple Scattering and Accidental Coincidences in the J-PET Detector Simulated Using GATE Package
    Kowalski, P.
    Moskal, P.
    Wislicki, W.
    Raczynski, L.
    Bednarski, T.
    Bialas, P.
    Bulka, J.
    Czerwinski, E.
    Gajos, A.
    Gruntowski, A.
    Kaminska, D.
    Kaplon, L.
    Kochanowski, A.
    Korcyl, G.
    Kowal, J.
    Kozik, T.
    Krzemien, W.
    Kubicz, E.
    Niedzwiecki, Sz
    Palka, M.
    Rudy, Z.
    Salabura, P.
    Sharma, N. G.
    Silarski, M.
    Slomski, A.
    Smyrski, J.
    Strzelecki, A.
    Wieczorek, A.
    Wochlik, I.
    Zielinski, M.
    Zon, N.
    ACTA PHYSICA POLONICA A, 2015, 127 (05) : 1505 - 1512
  • [37] Time Over Threshold as a measure of energy response of plastic scintillators used in the J-PET detector
    Sharma, Sushil
    MESON 2018 - 15TH INTERNATIONAL WORKSHOP ON MESON PHYSICS, 2019, 199
  • [38] Calculation of the time resolution of the J-PET tomograph using kernel density estimation
    Raczynski, L.
    Wislicki, W.
    Krzemien, W.
    Kowalski, P.
    Alfs, D.
    Bednarski, T.
    Bialas, P.
    Curceanu, C.
    Czerwinski, E.
    Dulski, K.
    Gajos, A.
    Glowacz, B.
    Gorgol, M.
    Hiesmayr, B.
    Jasinska, B.
    Kaminska, D.
    Korcyl, G.
    Kozik, T.
    Krawczyk, N.
    Kubicz, E.
    Mohammed, M.
    Pawlik-Niedzwiecka, M.
    Niedzwiecki, S.
    Palka, M.
    Rudy, Z.
    Rundel, O.
    Sharma, N. G.
    Silarski, M.
    Smyrski, J.
    Strzelecki, A.
    Wieczorek, A.
    Zgardzinska, B.
    Zielinski, M.
    Moskal, P.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (12): : 5076 - 5097
  • [39] Hit Time and Hit Position Reconstruction in the J-PET Detector Based on a Library of Averaged Model Signals
    Moskal, P.
    Sharma, N. G.
    Silarski, M.
    Bednarski, T.
    Bialas, P.
    Bulka, J.
    Czerwinski, E.
    Gajos, A.
    Kaminska, D.
    Kaplon, L.
    Kochanowski, A.
    Korcyl, G.
    Kowal, J.
    Kowalski, P.
    Kozik, T.
    Krzemien, W.
    Kubicz, E.
    Niedzwiecki, Sz
    Palka, M.
    Raczynski, L.
    Rudy, Z.
    Rundel, O.
    Salabura, P.
    Slomski, A.
    Smyrski, J.
    Strzelecki, A.
    Wieczorek, A.
    Wislicki, W.
    Wochlik, I.
    Zielinski, M.
    Zon, N.
    ACTA PHYSICA POLONICA A, 2015, 127 (05) : 1495 - 1499
  • [40] A study of time dependence of ortho-positronium annihilation in a poly(butadiene) at different temperatures:: a meaning of I3 parameter
    Sausa, O
    Zrubcová, J
    Band, P
    Kristiak, J
    Bartos, J
    RADIATION PHYSICS AND CHEMISTRY, 2000, 58 (5-6) : 479 - 483