Effect of shear-span/depth ratio on debonding failures of FRP-strengthened RC beams

被引:29
|
作者
Al-Saawani, Mohammed A. [1 ]
El-Sayed, Ahmed K. [1 ]
Al-Negheimish, Abdulaziz, I [1 ]
机构
[1] King Saud Univ, Ctr Excellence Concrete Res & Testing, Dept Civil Engn, POB 800, Riyadh 11421, Saudi Arabia
来源
关键词
Concrete beams; FRP strengthening; Shear span-depth ratio; Plate-end debonding; IC debonding; Concrete cover separation;
D O I
10.1016/j.jobe.2020.101771
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Debonding of fiber-reinforced polymers (FRP) from the concrete substrate is a major concern that compromises the effectiveness of FRP-strengthening. The intermediate-crack (IC) debonding and concrete cover separation (CCS) are the two main types of debonding failure of FRP-strengthened beams. Multiple factors may affect and lead to any of these two debonding failure modes. In this paper, the influence of shear-span/depth ratio (a(v)/d(s)) on the ultimate capacity and failure mode of FRP-strengthened beams is explored. A total of 14 beams comprised of 10 strengthened in flexure with carbon FRP (CFRP) sheets along with 4 control beams were investigated covering varying a(v)/d(s) ratios in the range of 1.5 to 7. For all the strengthened beams, the CFRP sheets were externally bonded to the soffit of the beams and extended close to the supports. The beams were simply supported and were tested in four-point bending. The results of this study showed clear effect of a(v)/d(s) ratio on the type of debonding failure and strain at failure. For the beams tested in this study, a threshold value of a(v)/d(s) ratio of 3.0 was identified at and below which the failure mode shifted from IC debonding to CCS. The results also indicated that all beams with CCS failed at the same shear load irrespective of a(v)/d(s) ratio. Comparison of experimental results with provisions of various design codes and guidelines to guard against debonding failures clearly shows the need for improved prediction of CCS failure.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Effect of load distribution on IC debonding in FRP-strengthened RC beams: Full-scale experiments
    Fu, B.
    Teng, J. G.
    Chen, G. M.
    Chen, J. F.
    Guo, Y. C.
    COMPOSITE STRUCTURES, 2018, 188 : 483 - 496
  • [22] Failure analysis of FRP-strengthened RC beams
    Saxena, Priyarn
    Toutanji, Houssam
    Noumowe, Albert
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2008, 12 (01) : 2 - 14
  • [23] Assessment of Diagonal Macrocrack-Induced Debonding Mechanisms in FRP-Strengthened RC Beams
    Huang, Yiqun
    Zhang, Wei
    Liu, Xiang
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2022, 26 (05)
  • [24] Intermediate crack debonding in FRP-strengthened RC beams: FE analysis and strength model
    Lu, X. Z.
    Teng, J. G.
    Ye, L. P.
    Jiang, J. J.
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2007, 11 (02) : 161 - 174
  • [25] Control of FRP Debonding in Strengthened RC Beams
    Bhatti, Abdul Qadir
    Kishi, Norimitsu
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2012, 37 (08) : 2103 - 2112
  • [26] Control of FRP Debonding in Strengthened RC Beams
    Abdul Qadir Bhatti
    Norimitsu Kishi
    Arabian Journal for Science and Engineering, 2012, 37 : 2103 - 2112
  • [27] Interfacial Behavior and debonding failures in FRP-Strengthened concrete slabs
    Elsayed, Walid
    Ebead, Usama A.
    Neale, Kenneth W.
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2007, 11 (06) : 619 - 628
  • [28] Modeling of debonding failure for RC beams strengthened in shear with NSM FRP reinforcement
    Rizzo, Andrea
    De Lorenzis, Laura
    CONSTRUCTION AND BUILDING MATERIALS, 2009, 23 (04) : 1568 - 1577
  • [29] Shear Strength Model for FRP-Strengthened RC Beams with Adverse FRP-Steel Interaction
    Chen, G. M.
    Teng, J. G.
    Chen, J. F.
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2013, 17 (01) : 50 - 66
  • [30] Finite-Element Analysis and Strength Model for IC Debonding in FRP-Strengthened RC Beams
    Li, Xing-Hua
    Wu, Gang
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2018, 22 (05)