Resolution of lysosomes in living cells with a ratiometric molecular pH-meter

被引:16
|
作者
Li, Zhu [1 ]
Wu, Shuqi [1 ]
Han, Jiahuai [1 ]
Yang, Liu [1 ]
Han, Shoufa [1 ]
机构
[1] Xiamen Univ, Minist Educ Cell Biol & Tumor Cell Engn, Key Lab, Sch Life Sci,Coll Life Sci, Xiamen, Peoples R China
关键词
Ratiometric imaging; Molecular pH-meter; Apoptosis; Lysosomal acidity; INTRACELLULAR PH; DEATH; APOPTOSIS; NECROSIS; SENSOR;
D O I
10.1016/j.talanta.2013.05.036
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Intracellular acidic vesicles, constituted mostly by lysosomes, mediated a variety of biological events ranging from endocytosis, apoptosis, to cancer metastasis, etc. A chimeric molecular pH-meter (Lyso-DR), comprised of a dansyl fluorophore and proton activatable rhodamine-lactam, was prepared for ratiometric reporting of intralysosomal acidity. Exclusively confined in lysosomes, Lyso-DR exhibited pH dependent dual fluorescence emission bands which enable resolution of individual lysosomes in terms of acidity and quantitation of the overall intracellular lysosomal acidity, e.g. the lysosomal pH of HeLa cells is around pH 5.0 whereas that of L929 cells is around pH 6.2. Lyso-DR effectively differentiated the lysosomal pH changes of cells undergoing apoptosis vs necrosis, suggesting its utility in investigations on lysosome involved biomedical processes. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:254 / 260
页数:7
相关论文
共 50 条
  • [11] A TEMPERATURE-COMPENSATING PH-METER
    LICHTENSTEIN, S
    CORCORAN, JS
    AMERICAN LABORATORY, 1981, 13 (05) : 108 - &
  • [12] VALUE OF PH-METER IN LABOR ROOM
    PICHEREAU, D
    ZAGO, J
    DAFFOS, F
    BAUDET, JH
    VIGE, F
    GAZETTE MEDICALE DE FRANCE, 1977, 84 (39): : 4367 - &
  • [13] INTERFACING A PH-METER TO ALLOW AUTOMATIC PH ADJUSTMENT
    HERTL, W
    RAMSEY, WS
    CARTER, CN
    SOKOLOSKI, EJ
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1982, 53 (02): : 260 - 261
  • [14] PH-METER WITH AUTOMATIC CLEANING OF ELECTRODES
    RADZIN, ZA
    SAFONOV, AF
    FEDOROV, VM
    INDUSTRIAL LABORATORY, 1994, 60 (01): : 16 - 18
  • [15] PRECIPITATION PH - COMPARISON OF PH-METER WITH INDICATOR KITS
    ALTWICKER, ER
    MICHAEL, M
    JOURNAL OF THE AIR POLLUTION CONTROL ASSOCIATION, 1985, 35 (01): : 44 - 45
  • [16] ADJUSTMENT OF PH-METER FOR MEASUREMENT OF SMALL CHANGES IN PH
    SVOBODOVA, X
    KARPENKO, V
    KALOUS, V
    CHEMICKE LISTY, 1977, 71 (02): : 192 - 195
  • [17] A LOW-COST PH-METER FOR THE CLASSROOM
    HARRIS, DL
    HARRIS, DC
    JOURNAL OF CHEMICAL EDUCATION, 1992, 69 (07) : 563 - 563
  • [18] A POCKET-SIZE PRECISION PH-METER
    不详
    ZUCKER, 1968, 21 (12): : 345 - &
  • [19] A TRANSISTORIZED MINIATURE PH-METER TRANSACID I
    CHALOUPK.J
    CHEMICKE LISTY, 1968, 62 (01): : 28 - &
  • [20] TECHNIQUE FOR INVESTIGATING ELECTRODE SYSTEM OF A PH-METER
    BENEVOLS.AS
    YUKHVONS.VP
    MEASUREMENT TECHNIQUES-USSR, 1966, (04): : 542 - &