Resolution of lysosomes in living cells with a ratiometric molecular pH-meter

被引:16
|
作者
Li, Zhu [1 ]
Wu, Shuqi [1 ]
Han, Jiahuai [1 ]
Yang, Liu [1 ]
Han, Shoufa [1 ]
机构
[1] Xiamen Univ, Minist Educ Cell Biol & Tumor Cell Engn, Key Lab, Sch Life Sci,Coll Life Sci, Xiamen, Peoples R China
关键词
Ratiometric imaging; Molecular pH-meter; Apoptosis; Lysosomal acidity; INTRACELLULAR PH; DEATH; APOPTOSIS; NECROSIS; SENSOR;
D O I
10.1016/j.talanta.2013.05.036
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Intracellular acidic vesicles, constituted mostly by lysosomes, mediated a variety of biological events ranging from endocytosis, apoptosis, to cancer metastasis, etc. A chimeric molecular pH-meter (Lyso-DR), comprised of a dansyl fluorophore and proton activatable rhodamine-lactam, was prepared for ratiometric reporting of intralysosomal acidity. Exclusively confined in lysosomes, Lyso-DR exhibited pH dependent dual fluorescence emission bands which enable resolution of individual lysosomes in terms of acidity and quantitation of the overall intracellular lysosomal acidity, e.g. the lysosomal pH of HeLa cells is around pH 5.0 whereas that of L929 cells is around pH 6.2. Lyso-DR effectively differentiated the lysosomal pH changes of cells undergoing apoptosis vs necrosis, suggesting its utility in investigations on lysosome involved biomedical processes. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:254 / 260
页数:7
相关论文
共 50 条
  • [1] PH-METER REVISIONS
    EISNOR, CR
    JOURNAL OF CHEMICAL EDUCATION, 1982, 59 (03) : 240 - 240
  • [2] THE APPLE PH-METER
    BEHM, RK
    BRENEMAN, GL
    JOURNAL OF CHEMICAL EDUCATION, 1983, 60 (07) : 567 - 567
  • [3] Laboratory pH-meter
    不详
    TENSIDE SURFACTANTS DETERGENTS, 1996, 33 (01) : 14 - 14
  • [4] DEVELOPMENT OF THE PH-METER
    JASELSKIS, B
    MOORE, CE
    VONSMOLINSKI, A
    ACS SYMPOSIUM SERIES, 1989, 390 : 254 - 271
  • [5] PH-METER FOR ALL REQUIREMENTS
    NIKLASSON, R
    KEMISK TIDSKRIFT, 1984, 96 (08): : 26 - 27
  • [6] HIGH PRECISION PH-METER
    不详
    ZUCKER, 1968, 21 (14): : 406 - &
  • [7] CHOOSING A PORTABLE PH-METER
    WESTCOTT, CC
    INSTRUMENTS & CONTROL SYSTEMS, 1977, 50 (06): : 75 - 76
  • [8] RELIABILITY OF PH-METER IN ALKALINE PH REGIONS
    KIHARA, H
    TAKAHASHI, E
    SEIKAGAKU, 1978, 50 (01): : 30 - 33
  • [9] NEW CZECHOSLOVAK PH-METER ZPA
    VALEK, V
    GOTTSTEI.J
    CHEMICKE LISTY, 1966, 60 (05): : 669 - &
  • [10] NEW DIGITAL RADIOMETER PH-METER
    不详
    PATHOLOGIE BIOLOGIE, 1969, 17 (9-10): : 543 - &