Robust Estimation of Kinetic Parameters in Dynamic PET Imaging

被引:0
|
作者
Gao, Fei [1 ]
Liu, Huafeng [1 ]
Shi, Pengcheng [1 ]
机构
[1] Rochester Inst Technol, Golisano Coll Comp & Informat Sci, Rochester, NY 14623 USA
来源
MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION, MICCAI 2011, PT I | 2011年 / 6891卷
关键词
DIRECT RECONSTRUCTION; IMAGES; MAPS;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Dynamic PET imaging provides important information for biological research, clinical diagnosis and pharmacokinetic analysis through kinetic modeling and data-driven parameter estimation. Kinetic parameters quantitatively describe dynamic material exchange and metabolism of radiotracers in plasma and tissues. While many efforts have been devoted to estimate kinetic parameters from dynamic PET, the poor statistical properties of the measurement data in low count dynamic acquisition and the uncertainties in estimating the arterial input function have limited the accuracy and reliability of the kinetic parameter estimation. Additionally, the quantitative analysis of individual kinetic parameters is not yet implemented. In this paper, we present a robust kinetic parameter estimation framework which is robust to both the poor statistical properties of measurement data in dynamic PET and the uncertainties in estimated arterial input function, and is able to analyze every single kinetic parameter quantitatively. The strategy is optimized with robust H-infinity estimation under minimax criterion. Experiments are conducted on Monte Carlo sirnulated data set for quantitative analysis and validation, and on real patient scans for assessment of clinical potential.
引用
收藏
页码:492 / 499
页数:8
相关论文
共 50 条
  • [31] [18F] Sodium Fluoride PET Kinetic Parameters in Bone Imaging
    Puri, Tanuj
    Frost, Michelle L.
    Cook, Gary J.
    Blake, Glen M.
    TOMOGRAPHY, 2021, 7 (04) : 843 - 854
  • [32] A Nonlocal Averaging Technique for Kinetic Parameter Estimation from Dynamic PET Data
    Dutta, Joyita
    El Fakhri, Georges
    Leahy, Richard M.
    Li, Quanzheng
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3562 - 3566
  • [33] Compressed sensing for kinetic parameter estimation of sparsely sampled dynamic PET data
    Wong, Koon-Pong
    Huang, Sung-Cheng
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [34] Simultaneous segmentation, kinetic parameter estimation, and uncertainty visualization of dynamic PET images
    Saad, Ahmed
    Smith, Ben
    Hamarneh, Ghassan
    Moeller, Torsten
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION- MICCAI 2007, PT 2, PROCEEDINGS, 2007, 4792 : 726 - +
  • [35] Multi-bed Tracer Kinetic Imaging of Micro-parameters from Dynamic Time-of-flight PET Data
    Kotasidis, Fotis A.
    Karakatsanis, Nicolas A.
    Mehranian, Abolfazl
    Zaidi, Habib
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [36] Evaluation of Respiratory Motion Correction on Liver Kinetic Analysis for Dynamic PET Imaging
    Shao, Y.
    Wang, J.
    Wang, X.
    Cui, J.
    Li, N.
    Huo, L.
    Zhang, H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (SUPPL 1) : S867 - S868
  • [37] Parameter estimation using reduced dynamic imaging data in PET studies
    Li, XJ
    Feng, DG
    ICSP '96 - 1996 3RD INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING, PROCEEDINGS, VOLS I AND II, 1996, : 859 - 862
  • [38] Robust Dynamic Estimation
    Rubel, Olivier
    Naik, Prasad A.
    MARKETING SCIENCE, 2017, 36 (03) : 453 - 467
  • [39] An adaptation of ridge regression for improved estimation of kinetic model parameters from PET studies
    Byrtek, M
    O'Sullivan, F
    Muzi, M
    Spence, AM
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (01) : 63 - 68
  • [40] An adaptation of ridge regression for improved estimation of kinetic model parameters from PET studies
    Byrtek, M
    O'Sullivan, F
    Muzi, M
    Spence, AM
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 3120 - 3124