Technique, radiation safety and image quality for chest X-ray imaging through glass and in mobile settings during the COVID-19 pandemic

被引:27
|
作者
Brady, Zoe [1 ,2 ]
Scoullar, Heather [1 ]
Grinsted, Ben [1 ]
Ewert, Kyle [1 ]
Kavnoudias, Helen [1 ,2 ,3 ]
Jarema, Alexander [1 ]
Crocker, James [1 ]
Wills, Rob [1 ]
Houston, Gillian [1 ]
Law, Meng [1 ,2 ,4 ]
Varma, Dinesh [1 ,3 ]
机构
[1] Alfred Hlth, Dept Radiol, Melbourne, Vic, Australia
[2] Monash Univ, Dept Neurosci, Melbourne, Vic, Australia
[3] Monash Univ, Dept Surg, Melbourne, Vic, Australia
[4] Monash Univ, Dept Elect & Comp Syst Engn, Melbourne, Vic, Australia
关键词
Chest imaging; X-ray; Pandemic; Radiation safety; Portable; COVID-19;
D O I
10.1007/s13246-020-00899-8
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The COVID-19 pandemic in 2020 has led to preparations within our hospital for an expected surge of patients. This included developing a technique to perform mobile chest X-ray imaging through glass, allowing the X-ray unit to remain outside of the patient's room, effectively reducing the cleaning time associated with disinfecting equipment. The technique also reduced the infection risk of radiographers. We assessed the attenuation of different types of glass in the hospital and the technique parameters required to account for the glass filtration and additional source to image distance (SID). Radiation measurements were undertaken in a simulated set-up to determine the appropriate position for staff inside and outside the room to ensure occupational doses were kept as low as reasonably achievable. Image quality was scored and technical parameter information collated. The alternative to imaging through glass is the standard portable chest X-ray within the room. The radiation safety requirements for this standard technique were also assessed. Image quality was found to be acceptable or borderline in 90% of the images taken through glass and the average patient dose was 0.02 millisieverts (mSv) per image. The majority (67%) of images were acquired at 110 kV, with an average 5.5 mAs and with SID ranging from 180 to 300 cm. With staff positioned at greater than 1 m from the patient and at more than 1 m laterally from the tube head outside the room to minimise scatter exposure, air kerma values did not exceed 0.5 microgray (mu Gy) per image. This method has been implemented successfully.
引用
收藏
页码:765 / 779
页数:15
相关论文
共 50 条
  • [1] Technique, radiation safety and image quality for chest X-ray imaging through glass and in mobile settings during the COVID-19 pandemic
    Zoe Brady
    Heather Scoullar
    Ben Grinsted
    Kyle Ewert
    Helen Kavnoudias
    Alexander Jarema
    James Crocker
    Rob Wills
    Gillian Houston
    Meng Law
    Dinesh Varma
    Physical and Engineering Sciences in Medicine, 2020, 43 : 765 - 779
  • [2] Fever and an abnormal chest X-ray during the COVID-19 pandemic
    Ruttens, David
    Van Kerrebroeck, Margaretha
    Vandewalle, Jan
    Falter, Maarten
    Daenen, Marc
    Thevissen, Kristof
    Wirix, Mieke
    Thomeer, Michiel
    RESPIRATORY MEDICINE CASE REPORTS, 2020, 31
  • [3] Modified Chest X-Ray Radiography through Glass Window for Imaging COVID-19 Pneumonia: Techniques and Radiation Dose
    Suliman, Ibrahim I.
    Khouqeer, Ghada A.
    Ahmed, Nada A.
    Abuzaid, Mohamed M.
    Sulieman, Abdelmoneim
    INTERNATIONAL JOURNAL OF BIOMEDICINE, 2023, 13 (02) : 194 - 201
  • [4] Social Distancing with Portable Chest Radiographs during the COVID-19 Pandemic: Assessment of Radiograph Technique and Image Quality Obtained at 6 Feet and Through Glass
    Gange, Christopher P.
    Pahade, Jay K.
    Cortopassi, Isabel
    Bader, Anna S.
    Bokhari, Jamal
    Hoerner, Matthew
    Thomas, Kelly M.
    Rubinowitz, Ami N.
    RADIOLOGY-CARDIOTHORACIC IMAGING, 2020, 2 (06):
  • [5] The role of initial chest X-ray in triaging patients with suspected COVID-19 during the pandemic
    Hyunjoong W. Kim
    K. M. Capaccione
    Gen Li
    Lyndon Luk
    Reginald S. Widemon
    Ozair Rahman
    Volkan Beylergil
    Ryan Mitchell
    Belinda M. D’Souza
    Jay S. Leb
    Shifali Dumeer
    Stuart Bentley-Hibbert
    Michael Liu
    Sachin Jambawalikar
    John H. M. Austin
    Mary Salvatore
    Emergency Radiology, 2020, 27 : 617 - 621
  • [6] The role of initial chest X-ray in triaging patients with suspected COVID-19 during the pandemic
    Kim, Hyunjoong W.
    Capaccione, K. M.
    Li, Gen
    Luk, Lyndon
    Widemon, Reginald S.
    Rahman, Ozair
    Beylergil, Volkan
    Mitchell, Ryan
    D'Souza, Belinda M.
    Leb, Jay S.
    Dumeer, Shifali
    Bentley-Hibbert, Stuart
    Liu, Michael
    Jambawalikar, Sachin
    Austin, John H. M.
    Salvatore, Mary
    EMERGENCY RADIOLOGY, 2020, 27 (06) : 617 - 621
  • [7] Proof of Concept: Phantom Study to Ensure Quality and Safety of Portable Chest Radiography Through Glass During the COVID-19 Pandemic
    Rai, Archana
    MacGregor, Kate
    Hunt, Bryce
    Gontar, Alex
    Ditkofsky, Noah
    Deva, Djeven
    Mathur, Shobhit
    INVESTIGATIVE RADIOLOGY, 2021, 56 (03) : 135 - 140
  • [8] X-Rays through the Looking Glass: Mobile Imaging Dosimetry and Image Quality of Suspected COVID-19 Patients
    Schelleman, Alexandra
    Boyd, Chris
    JOURNAL OF RADIATION PROTECTION AND RESEARCH, 2021, 46 (03): : 120 - 126
  • [9] Chest X-Ray Imaging Severity Score of COVID-19 Pneumonia
    Garea-Llano, Eduardo
    Diaz-Berenguer, Abel
    Sahli, Hichem
    Gonzalez-Dalmau, Evelio
    PATTERN RECOGNITION, MCPR 2023, 2023, 13902 : 211 - 220
  • [10] An Improved Machine Learnings Diagnosis Technique for COVID-19 Pandemic Using Chest X-ray Images
    Awotunde, Joseph Bamidele
    Ajagbe, Sunday Adeola
    Oladipupo, Matthew A.
    Awokola, Jimmisayo A.
    Afolabi, Olakunle S.
    Mathew, Timothy O.
    Oguns, Yetunde J.
    APPLIED INFORMATICS (ICAI 2021), 2021, 1455 : 319 - 330