Dosimetric impact of statistical uncertainty on Monte Carlo dose calculation algorithm in volumetric modulated arc therapy using Monaco TPS for three different clinical cases

被引:8
|
作者
Palanisamy, Mohandass [1 ,2 ]
David, Khanna [1 ]
Durai, Manigandan [3 ]
Bhalla, Narendra [2 ]
Puri, Abhishek [2 ]
机构
[1] Karunya Inst Technol & Sci, Sch Engn & Technol, Dept Phys, Coimbatore, Tamil Nadu, India
[2] Fortis Hosp, Fortis Canc Inst, Dept Radiat Oncol, Mohali, Punjab, India
[3] Medanta Medicity Hosp, Dept Radiotherapy, Gurgaon, Haryana, India
关键词
Statistical uncertainty; Monte Carlo dose algorithm; VMAT; Lung; Larynx; Prostate; CALCULATION ACCURACY; DISTRIBUTIONS; RADIOTHERAPY; IMRT;
D O I
10.1016/j.rpor.2019.01.005
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Aim To study the dosimetric impact of statistical uncertainty (SU) per plan on Monte Carlo MC) calculation in MonacoTMtreatment planning system (TPS) during volumetric modulated arc therapy (VMAT) for three different clinical cases. Background: During MC calculation SU is an important factor to decide dose calculation accuracy and calculation time. It is necessary to evaluate optimal acceptance of SU for quality plan with reduced calculation time. Materials and methods: Three different clinical cases as the lung, larynx, and prostate treated using VMAT technique were chosen. Plans were generated with MonacoTMV5.11 TPS with 2% statistical uncertainty. By keeping all other parameters constant, plans were recalculated by varying SU, 0.5%, 1%, 2%, 3%, 4%, and 5%. For plan evaluation, conformity index ( CI), homogeneity index (HI), dose coverage to PTV, organ at risk (OAR) dose, normal tissue receiving dose > 5 Gy and >= 10 Gy, integral dose (NTID), calculation time, gamma pass rate, calculation reproducibility and energy dependency were analyzed. Results: CI and HI improve as SU increases from 0.5% to 5%. No significant dose difference was observed in dose coverage to PTV, OAR doses, normal tissue receiving dose >= 5 Gy and >= 10 Gy and NTID. Increase of SU showed decrease in calculation time, gamma pass rate and increase in PTV max dose. No dose difference was seen in calculation reproducibility and dependent on energy. Conclusion: For VMAT plans, SU can be accepted from 1% to 3% per plan with reduced calculation time without compromising plan quality and deliverability by accepting variations inpoint dose within the target. (C) 2019 Greater Poland Cancer Centre. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:188 / 199
页数:12
相关论文
共 24 条
  • [11] Development of clinical application program for radiotherapy induced cancer risk calculation using Monte Carlo engine in volumetric-modulated arc therapy
    Kang, Dong-Jin
    Shin, Young-Joo
    Jeong, Seonghoon
    Jung, Jae-Yong
    Lee, Hakjae
    Lee, Boram
    RADIATION ONCOLOGY, 2021, 16 (01)
  • [12] Patient-Specific Quality Assurance Using Monte Carlo Dose Calculation and Elekta Log Files for Prostate Volumetric-Modulated Arc Therapy
    Katsuta, Yoshiyuki
    Kadoya, Noriyuki
    Fujita, Yukio
    Shimizu, Eiji
    Matsunaga, Kenichi
    Sawada, Kinya
    Matsushita, Haruo
    Majima, Kazuhiro
    Jingu, Keiichi
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2017, 16 (06) : 1220 - 1225
  • [13] Investigating the dosimetric effects of grid size on dose calculation accuracy using volumetric modulated arc therapy in spine stereotactic radiosurgery
    Snyder, Karen Chin
    Liu, Manju
    Zhao, Bo
    Huang, Yimei
    Wen, Ning
    Chetty, Indrin J.
    Siddiqui, M. Salim
    JOURNAL OF RADIOSURGERY AND SBRT, 2016, 4 (04): : 303 - 313
  • [14] Dosimetric Impact of Breathing Cycle Irregularity On Target Dose for Pancreatic Cancer Using Single-Arc Volumetric Modulated Arc Therapy
    Nakamura, M.
    Goto, Y.
    Ishihara, V.
    Mukutnoto, N.
    Kishi, T.
    Mizowaki, T.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [15] Assessment of Clinical Impact of Analytical Dose Calculation in TPS for Proton PBS Treatment Using Fast Monte Carlo Simulation
    Huang, S.
    Souris, K.
    Li, S.
    Kang, M.
    Janssens, G.
    Lin, A.
    Garver, E. H.
    Ainsley, C.
    Xiao, Y.
    Lin, L.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : S57 - S58
  • [16] Dosimetric comparison of analytical anisotropic algorithm and the two dose reporting modes of Acuros XB dose calculation algorithm in volumetric modulated arc therapy of carcinoma lung and carcinoma prostate
    Gopalakrishnan, Zhenia
    Bhasi, Saju
    Raghukumar, P.
    V. Menon, Sharika
    Sarin, B.
    Thayil, Anna George
    Nair, Raghuram K.
    MEDICAL DOSIMETRY, 2022, 47 (03) : 280 - 287
  • [17] Monte Carlo-Dose Verification of Volumetric Modulated Arc Therapy Plans Using AAPM TG-119 Test Patterns
    Onizuka, R.
    Araki, F.
    Ohno, T.
    Nakaguchi, Y.
    MEDICAL PHYSICS, 2016, 43 (06) : 3547 - 3547
  • [18] Dosimetric Impact of Leaf Gap Error on Target Dose Using Volumetric Modulated Arc Therapy and Intensity-Modulated Radiation Therapy with Flattening Filter-Free Beam
    Wakai, N.
    Asakawa, I.
    Tamamoto, T.
    Morimoto, Y.
    Yamaki, K.
    Morimoto, M.
    Miura, S.
    Hasegawa, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E733 - E734
  • [19] Dosimetric impact of different CT datasets for stereotactic treatment planning using 3D conformal radiotherapy or volumetric modulated arc therapy
    Oechsner, Markus
    Odersky, Leonhard
    Berndt, Johannes
    Combs, Stephanie Elisabeth
    Wilkens, Jan Jakob
    Duma, Marciana Nona
    RADIATION ONCOLOGY, 2015, 10
  • [20] Quantitative evaluation of dosimetric uncertainties in electron therapy by measurement and calculation using the electron Monte Carlo dose algorithm in the Eclipse treatment planning system
    Ali, Imad
    Alsbou, Nesreen
    Ahmad, Salahuddin
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (01):