Development of real-time x-ray microtomography system

被引:14
|
作者
Takano, H. [1 ]
Morikawa, M. [1 ]
Konishi, S. [1 ]
Azuma, H. [1 ]
Shimomura, S. [1 ]
Tsusaka, Y. [1 ]
Nakano, S.
Kosaka, N.
Yamamoto, K.
Kagoshima, Y. [1 ]
机构
[1] Univ Hyogo, Grad Sch Mat Sci, Ctr Novel Mat Sci Multiextreme Condit, Kamigori, Hyogo 6791297, Japan
关键词
TOMOGRAPHIC MICROSCOPY;
D O I
10.1088/1742-6596/463/1/012025
中图分类号
TH742 [显微镜];
学科分类号
摘要
We have developed a four-dimensional (4D) x-ray microcomputed tomography (CT) system that can obtain time-lapse CT volumes in real time. The system consists of a high-speed sample rotation system and a high-frame-rate x-ray imager, which are installed at a synchrotron radiation x-ray beamline. As a result of system optimization and introduction of a "zoom resolution" procedure, a real-time 4D CT movie with a frame rate of 30 was obtained with a voxel size of 2.5 mu m using 10 keV x-rays.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] Development of an X-ray imaging detector for high-energy X-ray microtomography
    Hoshino, Masato
    Uesugi, Kentaro
    Yagi, Naoto
    JOURNAL OF SYNCHROTRON RADIATION, 2020, 27 : 934 - 940
  • [32] X-ray fluorescence microtomography with a Wolter mirror system
    Watanabe, N
    Yamamoto, K
    Takano, H
    Ohigashi, T
    Yokosuka, H
    Aota, T
    Aoki, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 : 837 - 840
  • [33] Development of an X-ray real-time stereo imaging technique using synchrotron radiation
    Hoshino, Masato
    Uesugi, Kentaro
    Pearson, James
    Sonobe, Takashi
    Shirai, Mikiyasu
    Yagi, Naoto
    JOURNAL OF SYNCHROTRON RADIATION, 2011, 18 : 569 - 574
  • [34] Evaluation of a microtomography system with an X-ray microfocus tube
    Lopes, RT
    Rodrigues, JL
    De Assis, JT
    De Jesus, EFO
    De Oliveira, LF
    APPLIED RADIATION AND ISOTOPES, 1997, 48 (10-12) : 1437 - 1442
  • [35] X-RAY MICROTOMOGRAPHY OF BONE
    ELLIOTT, JC
    DOVER, SD
    METABOLIC BONE DISEASE & RELATED RESEARCH, 1984, 5 (01): : 50 - 50
  • [36] X-ray microtomography of materials
    Stock, SR
    INTERNATIONAL MATERIALS REVIEWS, 1999, 44 (04) : 141 - 164
  • [37] X-ray microtomography in biology
    Mizutani, Ryuta
    Suzuki, Yoshio
    MICRON, 2012, 43 (2-3) : 104 - 115
  • [38] Real-time software for the wire per wire X-ray data acquisition system
    Briquet-Laugier, F
    Baumlin, P
    Boulin, C
    Golding, F
    Koch, M
    Epstein, A
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (02) : 284 - 287
  • [39] REAL-TIME X-RAY INSPECTION SYSTEM FOR FAST FLUX TEST FACILITY FUEL
    JACKSON, CN
    GRAY, WH
    SHAW, CB
    MATERIALS EVALUATION, 1973, 31 (10) : 199 - 204
  • [40] X-ray diffraction microtomography
    Grant, J.A., 1600, (06):