Fluorescence resonance energy transfer by S-layer coupled fluorescence dyes

被引:5
|
作者
Weinert, Ulrike [1 ]
Pollmann, Katrin [1 ]
Raff, Johannes [1 ,2 ]
机构
[1] Helmholtz Zentrum Dresden Rossendorf, Helmholtz Inst Freiberg Resource Technol, D-09599 Freiberg, Germany
[2] Helmholtz Zentrum Dresden Rossendorf, Inst Resource Ecol, D-01328 Freiberg, Germany
来源
关键词
Fluorescence resonance energy transfer; Surface layer proteins; EDC; Chemical modification; Sensory layers; Detection; STEADY-STATE FLUORESCENCE; SURFACE-LAYER; SPECTRAL PROPERTIES; PROTEINS; BIOSENSORS; LIFETIME; MATRIX; SERUM; FRET;
D O I
10.1016/j.snb.2013.05.051
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper two fluorescence dyes were coupled to surface layer (S-layer) proteins of Lysinibacillus sphaericus A12 and Lysinibacillus sphaericus B53 to easily generate a fluorescence resonance energy transfer (FRET). S-layer proteins are structure proteins which self-assemble in aqueous solutions, on surfaces and at interfaces forming 2D-paracrystalline structures with a defined symmetry in nanometer range. These properties and the fact, that a lot of modifiable functional groups are available on their surface, make them a perfect coating and binding matrix for the generation of functionalized surfaces, e.g. needed for a sensor assembly. Here we chemically link two fluorescence dyes, which are able to perform a FRET, to S-layer proteins by carbodiimide-crosslinking chemistry. Fluorescence dyes were coupled to the protein with a yield of around 54 mol%, demonstrating a modification of every second protein monomer if fluorescence dyes are statistical distributed. A FRET could be detected between the two fluorescence dyes when linked to protein polymers whereas no FRET could be detected if fluorescence dyes are linked to protein monomers. This demonstrates, that the polymer structure is essential for FRET and that fluorescence dyes are statisticaly distributed on protein polymers with a close proximity of donor and acceptor dye. Due to the fact that the used S-layer proteins build a unit cell of p4 symmetry, it can be assumed that two fluorescence dyes are linked to one unit cell. In this paper the FRET pair arrangement and its optimization is described in which the FRET efficiency can be increased from 6 to 40%, simply by varying the molar ratio of donor:acceptor. In result a sensory surface can be generated and used for detection of numerous substances in water like pharmaceuticals or heavy metals. (c) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:553 / 559
页数:7
相关论文
共 50 条
  • [41] A new fluorescence resonance energy transfer pair and its application to oligonucleotide labeling and fluorescence resonance energy transfer hybridization studies
    Gruber, M
    Wetzl, B
    Oswald, B
    Enderlein, J
    Wolfbeis, OS
    JOURNAL OF FLUORESCENCE, 2005, 15 (03) : 207 - 214
  • [42] Orderly Arranged Fluorescence Dyes as a Highly Efficient Chemiluminescence Resonance Energy Transfer Probe for Peroxynitrite
    Wang, Zhihua
    Teng, Xu
    Lu, Chao
    ANALYTICAL CHEMISTRY, 2015, 87 (06) : 3412 - 3418
  • [43] Studies on fluorescence resonance energy transfer between dyes and water-soluble quantum dots
    Chen, QD
    Ma, QA
    Wan, Y
    Su, XG
    Lin, ZB
    Jin, QH
    LUMINESCENCE, 2005, 20 (4-5) : 251 - 255
  • [44] Temporal fluctuations of fluorescence resonance energy transfer between two dyes conjugated to a single protein
    Ha, TJ
    Ting, AY
    Liang, J
    Deniz, AA
    Chemla, DS
    Schultz, PG
    Weiss, S
    CHEMICAL PHYSICS, 1999, 247 (01) : 107 - 118
  • [45] Studies on fluorescence resonance energy transfer between dyes and water-soluble quantum dots
    Wang, Xin-Yan
    Ma, Qiang
    Li, Ya-Bing
    Li, Bing
    Su, Xing-Guang
    Jin, Qin-Han
    CANADIAN JOURNAL OF ANALYTICAL SCIENCES AND SPECTROSCOPY, 2005, 50 (03): : 141 - 146
  • [46] Influence of Dye Hydrophobicity on the Efficiency of Fluorescence Resonance Energy Transfer Between Dyes in Surfactant Micelles
    Yefimova, S. L.
    Lebed, A. S.
    Guralchuk, G. Ya
    Sorokin, A. V.
    Malyukin, Yu V.
    MOLECULAR CRYSTALS AND LIQUID CRYSTALS, 2011, 535 (01) : 204 - 211
  • [47] Reliable and global measurement of fluorescence resonance energy transfer using fluorescence microscopes
    Xia, ZP
    Liu, YH
    BIOPHYSICAL JOURNAL, 2001, 81 (04) : 2395 - 2402
  • [48] Polyethylenimine/Oligonucleotide Polyplexes Investigated by Fluorescence Resonance Energy Transfer and Fluorescence Anisotropy
    Ko, Young Tag
    Bickel, Ulrich
    Huang, Juyang
    OLIGONUCLEOTIDES, 2011, 21 (02) : 109 - 114
  • [49] Fluorescence resonance energy transfer (FRET) and fluorescence lifetime imaging microscopy (FLIM)
    Jovin, TM
    Lidke, DS
    Jares-Erijman, EA
    FROM CELLS TO PROTEINS: IMAGING NATURE ACROSS DIMENSIONS, 2005, 3 : 209 - 216
  • [50] Fluorescence resonance energy transfer imaging microscopy and fluorescence polarization imaging microscopy
    Yan, YL
    Marriott, G
    BIOPHOTONICS, PT A, 2003, 360 : 561 - 580