Failure mechanism of casing treatment in improving stability of a highly loaded two-stage axial compressor

被引:14
|
作者
Wang Wei [1 ,4 ]
Lu Jin-ling [1 ,4 ]
Luo Xing-qi [1 ,4 ]
Huang Rui [1 ,4 ]
Chu Wu-li [2 ,3 ]
机构
[1] Xian Univ Technol, Fac Water Resources & Hydroelect Engn, Xian 710048, Peoples R China
[2] Northwestern Polytech Univ, Sch Power & Energy, Xian 710072, Peoples R China
[3] Collaborat Innovat Ctr Adv Aeroengine, Beijing 100191, Peoples R China
[4] State Key Lab Ecohydraul Northwest Arid Reg, Xian 710048, Peoples R China
基金
中国国家自然科学基金;
关键词
Aircraft compressor; Casing treatment; Stall margin; Failure mechanism; Tip blockage; TIP INJECTION; STALL; PERFORMANCE;
D O I
10.1016/j.ast.2020.105979
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
Casing treatment is a powerful method for enhancing stability of certain aircraft compressors in which tip leakage vortex (TLV) triggers stall. An optimized slot-type casing treatment was installed on the first rotor of a highly loaded two-stage compressor. The experimental result showed that the casing treatment could not increase the compressor stability at three tested speeds. This study aims to understand the failure mechanism of the casing treatment for developing an effective method to depress stall. A "three-step method" is proposed to determine the stall-limiting location and understand the underlying stall mechanism. At 90% speed, there is a spike in the aerodynamic flow parameters in the tip region of the first rotor under the near stall condition compared with that under the design condition. The spike is induced by an interaction among the TLV, boundary layer at the blade suction surface, and passage shockwave. Both the TLV and the shockwave-boundary layer interaction contribute to the accumulation of tip blockage which triggers compressor stall. The TLV does not break down under the near stall condition, but unsteady forward spillage of the TLV at the blade tip leading edge can be detected, resulting in unsteady tip flow. When the casing treatment is installed on the first rotor, a typical flow circulation is established in the slots. The intensity of the TLV and the flow unsteadiness are greatly depressed, and the discharge capability in the tip region is remarkably improved. However, the flow circulation cannot manipulate the fierce boundary layer separation induced by the shockwave, which causes increased tip blockage and reduced compressor stability. A coupled casing treatment, which can bleed the shockwave induced blockage, is proposed and found to be very effective in improving compressor stability. Therefore, the technology for damping the compressor stall should be capable of manipulating both the TLV and the shockwave induced boundary layer separation. At 100% speed, a shedding vortex is initiated at the hub of the second stator. This vortex expands sharply in the stalling process and triggers compressor stall. Variation of the location at which the compressor stalls is the reason for the failure of the casing treatment at 100% speed. (C) 2020 Elsevier Masson SAS. All rights reserved.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] EFFECT OF J-SHAPED CASING TREATMENT ON FLOW STABILITY AND PERFORMANCE OF AN AXIAL COMPRESSOR
    Pathan, Ramjan R.
    Nagpurwala, Quamber H.
    Ananthesha
    PROCEEDINGS OF THE ASME GAS TURBINE INDIA CONFERENCE 2012, 2012, : 139 - 148
  • [42] Parametric study of tip clearance - Casing treatment on performance and stability of a transonic axial compressor
    Beheshti, BH
    Teixeira, JA
    Ivey, PC
    Ghorbanian, K
    Farhanieh, B
    JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2004, 126 (04): : 527 - 535
  • [43] Mechanism of the interaction between casing treatment and tip leakage flow in a subsonic axial compressor
    Lu, Xingen
    Chu, Wuli
    Zhu, Junqiang
    Wu, Yanhui
    Proceedings of the ASME Turbo Expo 2006, Vol 6, Pts A and B, 2006, : 79 - 90
  • [44] Mechanism study of performance enhancement in a subsonic axial flow compressor with recirculating casing treatment
    Wang, Wei
    Chu, Wuli
    Zhang, Haoguang
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART G-JOURNAL OF AEROSPACE ENGINEERING, 2018, 232 (04) : 680 - 693
  • [45] SOME OBSERVATIONS AND EXPLORATION OF MECHANISM FOR SLOTTED CASING TREATMENT IN AXIAL FLOW COMPRESSOR.
    Liu Zhiwei
    Zhang, Changsheng
    Xibei Gongye Daxue Xuebao/Journal of Northwestern Polytechnical University, 1987, 5 (Extra Issue): : 31 - 39
  • [46] Stall inception and warning in a single-stage transonic axial compressor with axial skewed slot casing treatment
    Byeung Jun Lim
    Tae Choon Park
    Sejin Kwon
    Journal of Mechanical Science and Technology, 2014, 28 : 3569 - 3581
  • [47] The effect of variable stator on performance of a highly loaded tandem axial flow compressor stage
    Hamzeh Eshraghi
    Masoud Boroomand
    Abolghasem M. Tousi
    Mohammad Toude Fallah
    Ali Mohammadi
    Journal of Thermal Science, 2016, 25 : 223 - 230
  • [48] The Effect of Variable Stator on Performance of a Highly Loaded Tandem Axial Flow Compressor Stage
    Hamzeh Eshraghi
    Masoud Boroomand
    Abolghasem M.Tousi
    Mohammad Toude Fallah
    Ali Mohammadi
    JournalofThermalScience, 2016, 25 (03) : 223 - 230
  • [49] Stall inception and warning in a single-stage transonic axial compressor with axial skewed slot casing treatment
    Lim, Byeung Jun
    Park, Tae Choon
    Kwon, Sejin
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2014, 28 (09) : 3569 - 3581
  • [50] Integrated Design of Axial Slot Casing Treatment and Blades in a Low-Speed Single Stage Axial Compressor
    Fan, Zhonggang
    Du, Juan
    Ba, Dun
    Zhang, Min
    Yang, Chen
    JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2024, 146 (05):