DEVELOPMENT OF DIGITAL LOCK-IN IMAGE DETECTION SYSTEM AND ITS APPLICATION TO ODOR DISCRIMINATION USING CELL-BASED SENSOR ARRAY

被引:0
|
作者
Sukekawa, Yuji [1 ]
Mujiono, Totok [1 ]
Nakamoto, Takamichi [1 ]
机构
[1] Tokyo Inst Technol, Tokyo, Japan
关键词
Odor sensor; digital lock-in detection; principal component analysis; olfactory receptor; image processing;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Cell-based sensor expressing odorant receptor with fluorescent imaging has a potential for realization of high performance odor sensing system. In this study, we developed digital lock-in detection system for 2-dimensional data such as an image. Since the system has many digital lock-in amplifiers on field programmable gate array and process the image stream from a commercially available image sensor, it has a capability of robust measurement against ambient light. In order to test the system, the fluorescent image of the sensor array including two kinds of olfactory receptor was analyzed by using principal component analysis. The result suggests that the system can discriminate between different odors.
引用
收藏
页数:3
相关论文
共 50 条
  • [31] Binary mixture quantification using cell-based odor biosensor system with active sensing
    Sukekawa, Yuji
    Mitsuno, Hidefumi
    Kanzaki, Ryohei
    Nakamoto, Takamichi
    BIOSENSORS & BIOELECTRONICS, 2021, 179 (179):
  • [32] Development of a handheld mine detection system using a magnetoresistive sensor array
    Wold, RJ
    Nordman, CA
    Lavely, EM
    Tondra, M
    Lange, E
    Prouty, M
    DETECTION AND REMEDIATION TECHNOLOGIES FOR MINES AND MINELIKE TARGETS IV, PTS 1 AND 2, 1999, 3710 : 113 - 123
  • [33] Development and evaluation of a digital radiographic system based on CMOS image sensor
    Kim, HK
    Lee, SW
    Shin, YH
    Cho, HS
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (03) : 662 - 666
  • [34] A Study on the Weak Signal Detection System Applied to the High Field Research Based on the Digital Lock-In Technique and Wavelet Filter
    L. T. Huang
    X. T. Han
    J. T. Shi
    J. F. Xie
    L. Li
    Journal of Low Temperature Physics, 2013, 170 : 469 - 474
  • [35] A Study on the Weak Signal Detection System Applied to the High Field Research Based on the Digital Lock-In Technique and Wavelet Filter
    Huang, L. T.
    Han, X. T.
    Shi, J. T.
    Xie, J. F.
    Li, L.
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2013, 170 (5-6) : 469 - 474
  • [36] Discrimination and detection of benzaldehyde derivatives using sensor array based on fluorescent carbon nanodots
    Li, Yingying
    Liu, Xue
    Wu, Qiuhua
    Yi, Jie
    Zhang, Guolin
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 261 : 271 - 278
  • [37] Development of High-throughput Screening System for Osteogenic Drugs Using Cell-based Sensor.
    Hojo, H.
    Igawa, K.
    Ohba, S.
    Yano, F.
    Nakajima, K.
    Komiyama, Y.
    Yonezawa, T.
    Woo, J. T.
    Lichtler, A. C.
    Rowe, D. W.
    Ikeda, T.
    Nakamura, K.
    Kawaguchi, H.
    Chung, U.
    JOURNAL OF BONE AND MINERAL RESEARCH, 2008, 23 : S394 - S394
  • [38] Development of Rainfall Measurement System using Digital Image Processing Based Multi- Sensor Approach
    Ghonge, Pandharinath A.
    Mulgund, G.
    Godboley, B.
    Deotale, Nilesh
    Saxena, Arun
    Tuckley, Kushal R.
    JOURNAL OF ALGEBRAIC STATISTICS, 2022, 13 (02) : 1811 - 1828
  • [39] A cell-based sensor system for toxicity testing using multiwavelength fluorescence spectroscopy
    Fritzsche, Michael
    Fredriksson, J. Magnus
    Carlsson, Maria
    Mandenius, Carl-Fredrik
    ANALYTICAL BIOCHEMISTRY, 2009, 387 (02) : 271 - 275
  • [40] Sweet and bitter tastant discrimination from complex chemical mixtures using taste cell-based sensor
    Hui Guohua
    Mi Shanshan
    Chen Qingqing
    Chen Xing
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 192 : 361 - 368