DEVELOPMENT OF DIGITAL LOCK-IN IMAGE DETECTION SYSTEM AND ITS APPLICATION TO ODOR DISCRIMINATION USING CELL-BASED SENSOR ARRAY

被引:0
|
作者
Sukekawa, Yuji [1 ]
Mujiono, Totok [1 ]
Nakamoto, Takamichi [1 ]
机构
[1] Tokyo Inst Technol, Tokyo, Japan
关键词
Odor sensor; digital lock-in detection; principal component analysis; olfactory receptor; image processing;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Cell-based sensor expressing odorant receptor with fluorescent imaging has a potential for realization of high performance odor sensing system. In this study, we developed digital lock-in detection system for 2-dimensional data such as an image. Since the system has many digital lock-in amplifiers on field programmable gate array and process the image stream from a commercially available image sensor, it has a capability of robust measurement against ambient light. In order to test the system, the fluorescent image of the sensor array including two kinds of olfactory receptor was analyzed by using principal component analysis. The result suggests that the system can discriminate between different odors.
引用
收藏
页数:3
相关论文
共 50 条
  • [1] Odor biosensor system based on image lock-in measurement for odorant discrimination
    Sukekawa Y.
    Nakamoto T.
    Nakamoto, Takamichi (nakamoto@mn.ee.titech.ac.jp), 2018, Institute of Electrical Engineers of Japan (138) : 477 - 484
  • [2] Odor biosensor system based on image lock-in measurement for odorant discrimination
    Sukekawa, Yuji
    Nakamoto, Takamichi
    ELECTRONICS AND COMMUNICATIONS IN JAPAN, 2019, 102 (04) : 57 - 64
  • [3] Odor Discrimination Using Cell-Based Odor Biosensor System With Fluorescent Image Processing
    Sukekawa, Yuji
    Mitsuno, Hidefumi
    Kanzaki, Ryohei
    Nakamoto, Takamichi
    IEEE SENSORS JOURNAL, 2019, 19 (17) : 7192 - 7200
  • [4] Sensitivity Improvement by Applying Lock-In Technique to Fluorescent Instrumentation for Cell-Based Odor Sensor
    Mujiono, Totok
    Sukekawa, Yuji
    Nakamoto, Takamichi
    Mitsuno, Hidefumi
    Termtanasombat, Maneerat
    Kanzaki, Ryohei
    Misawa, Nobuo
    SENSORS AND MATERIALS, 2017, 29 (01) : 65 - 76
  • [5] A Cell-Based Odor Sensing System Using Fluorescent Technique and Lock-in Measurement Robust Against Disturbance
    Mujiono, T.
    Sukekawa, Y.
    Nakamoto, T.
    Mitsuno, H.
    Kanzaki, R.
    Misawa, N.
    2015 IEEE SENSORS, 2015, : 695 - 698
  • [6] Cell-Based Odorant Sensor Array for Odor Discrimination Based on Insect Odorant Receptors
    Maneerat Termtanasombat
    Hidefumi Mitsuno
    Nobuo Misawa
    Shinya Yamahira
    Takeshi Sakurai
    Satoshi Yamaguchi
    Teruyuki Nagamune
    Ryohei Kanzaki
    Journal of Chemical Ecology, 2016, 42 : 716 - 724
  • [7] Cell-Based Odorant Sensor Array for Odor Discrimination Based on Insect Odorant Receptors
    Termtanasombat, Maneerat
    Mitsuno, Hidefumi
    Misawa, Nobuo
    Yamahira, Shinya
    Sakurai, Takeshi
    Yamaguchi, Satoshi
    Nagamune, Teruyuki
    Kanzaki, Ryohei
    JOURNAL OF CHEMICAL ECOLOGY, 2016, 42 (07) : 716 - 724
  • [8] Spatially parallelized lock-in measurement technique for cell-based odor biosensor
    Sukekawa, Yuji
    Mujiono, Totok
    Nakamoto, Takamichi
    Mistuno, Hidefumi
    Kanzaki, Ryohei
    CHEMICAL SENSES, 2016, 41 (09) : E214 - E214
  • [9] Development of automated flow measurement system for cell-based odor sensor
    Sukekawa, Yuji
    Mujiono, Totok
    Nakamoto, Takamichi
    Mitsuno, Hidefumi
    Nakajima, Yuko
    Kanzaki, Ryohei
    Misawa, Nobuo
    IEEJ Transactions on Sensors and Micromachines, 2016, 136 (07) : 289 - 295
  • [10] Development of Automated Flow Measurement System for Cell-based Odor Sensor
    Sukekawa, Yuji
    Mujiono, Totok
    Nakamoto, Takamichi
    Mitsuno, Hidefumi
    Nakajima, Yuko
    Kanzaki, Ryohei
    Misawa, Nobuo
    ELECTRONICS AND COMMUNICATIONS IN JAPAN, 2017, 100 (09) : 41 - 49