Quantitative and imaging performance of uncooled microbolometer sensors

被引:9
|
作者
Marshall, CA
Breen, T
Kohin, M
Watson, W
Murphy, R
Butler, NR
Parker, TW
Perich, L
机构
来源
INFRARED TECHNOLOGY AND APPLICATIONS XXIII, PTS 1 AND 2 | 1997年 / 3061卷
关键词
uncooled sensors; microbolometers; NETD; MRTD; system performance;
D O I
10.1117/12.280338
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Lockheed Martin IR Imaging Systems is developing low cost, high performance, uncooled infrared imaging products for both military and commercial applications. These products are based on the microbolometer technology, a silicon micromachined sensor that combines wafer level silicon processing with a device structure capable of yielding excellent imaging performance. Here we report on the latest technical improvements and performance of an uncooled sensor as measured through laboratory and field testing. The performance of our uncooled sensor has been measured to determine sensor capabilities for insertion into both military and commercial products. Linearity of the sensor over a scene temperature range of 95 degrees C is less than 0.5%. Our sensors typically have temporal NETDs of less than 70 mK as well as spatial NETDs of less than 50 mK. MRTD performance is less than 0.4 degrees C at spatial frequencies more than 20% beyond Nyquist. Sensor stability over time has been measured and found to meet both commercial and military requirements. Spatial noise over a wide scene temperature range will be reported as well as other test results. Video will be used to demonstrate sensor performance capabilities in a variety of applications.
引用
收藏
页码:191 / 197
页数:7
相关论文
共 50 条
  • [21] YBaCuO uncooled microbolometer IRFPA
    Wada, H
    Sone, T
    Hata, H
    Nakaki, Y
    Kaneda, O
    Ohta, Y
    Ueno, M
    Kimata, M
    INFRARED TECHNOLOGY AND APPLICATIONS XXVII, 2001, 4369 : 297 - 304
  • [22] Design of uncooled microbolometer array
    Wang, T.
    Jia, G.X.
    Yuan, X.H.
    Bandaoti Guangdian/Semiconductor Optoelectronics, 2001, 22 (02):
  • [23] Method for expanding the dynamic range of the readout integration circuits for uncooled microbolometer sensors
    Belenky, A
    Fish, A
    Hamami, S
    Milrud, V
    Yadid-Pecht, O
    OPTICAL ENGINEERING, 2004, 43 (06) : 1274 - 1275
  • [24] Widening the dynamic range of the readout integration circuit for uncooled microbolometer infrared sensors
    Belenky, A
    Fish, A
    Hamami, S
    Milrud, V
    Yadid-Pecht, O
    2004 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOL 5, PROCEEDINGS, 2004, : 600 - 603
  • [25] Flexible camera applications of an advanced uncooled microbolometer thermal imaging core
    Rumbaugh, R
    Pongratz, S
    Breen, T
    Wickman, H
    Klug, R
    Gess, A
    Hays, J
    Hall, G
    Arion, T
    Owens, J
    Siviter, D
    THERMOSENSE XXVI, 2004, 5405 : 303 - 312
  • [26] THz uncooled microbolometer array development for active imaging and spectroscopy applications
    Simoens, Francois
    Meilhan, Jerome
    Pocas, Stephane
    Ouvrier-Buffet, Jean-Louis
    Maillou, Thierry
    Gellie, Pierre
    Barbieri, Stefano
    35TH INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER, AND TERAHERTZ WAVES (IRMMW-THZ 2010), 2010,
  • [27] Investigation of Uncooled Microbolometer Focal Plane Array Infrared Camera for Quantitative Thermography
    Joseph N. Zalameda
    William P. Winfree
    Journal of Nondestructive Evaluation, 2005, 24 : 1 - 9
  • [28] Investigation of uncooled microbolometer focal plane array infrared camera for quantitative thermography
    Zalameda, JN
    Winfree, WP
    JOURNAL OF NONDESTRUCTIVE EVALUATION, 2005, 24 (01) : 1 - 9
  • [29] European uncooled thermal imaging sensors
    McEwen, RK
    Manning, PA
    INFRARED TECHNOLOGY AND APPLICATIONS XXV, 1999, 3698 : 322 - 337
  • [30] An uncooled high-performance antenna-type microbolometer receiver
    Esman, A. K.
    Kuleshov, V. K.
    Zykov, G. L.
    MEASUREMENT TECHNIQUES, 2012, 55 (02) : 173 - 176