Dual-source parallel RF transmission for diffusion-weighted imaging of the abdomen using different b values: Image quality and apparent diffusion coefficient comparison with conventional single-source transmission
被引:10
|作者:
Guo, Lijun
[1
]
Liu, Cheng
[1
]
Chen, Weibo
[2
,3
]
Chan, Queenie
Wang, Guangbin
[1
]
机构:
[1] Shandong Univ, Shandong Med Imaging Res Inst, Jinan 250100, Peoples R China
[2] Philips Healthcare, Shanghai, Peoples R China
[3] Philips Healthcare, Hong Kong, Hong Kong, Peoples R China
关键词:
diffusion-weighted imaging;
image quality;
apparent diffusion coefficient;
dual-source parallel radiofrequency transmission;
single-source radiofrequency transmission;
b values;
HEPATOCELLULAR-CARCINOMA;
LIVER-LESIONS;
1.5;
T;
MRI;
EXCITATION;
EXPERIENCE;
BREATHHOLD;
SPLEEN;
BODY;
D O I:
10.1002/jmri.23869
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
Purpose: To prospectively and intraindividually evaluate what effects dual-source parallel radiofrequency (RF) transmission have on image quality and apparent diffusion coefficient (ADC) of abdomen diffusion-weighted imaging (DWI) using different b values, compared with the single-source RF transmission. Materials and Methods: Eighteen healthy male volunteers were enrolled in this Health Insurance Portability and Accountability Act (HIPAA)-compliant Institutional Review Board (IRB)-approved study. Abdominal DWI was performed with dual-source and single-source RF transmission at 3.0 T using a series of b-value combinations: 0/100, 0/500, 0/800, and 0/100/800. RF field homogeneity, subjective image quality, and signal to noise ratio (SNR) of each abdominal organ were evaluated. ADC values were calculated for each abdominal organ. Wilcoxon test and repeated-measures analysis of variance was used to calculate statistical significance. Results: The parallel RF transmission significantly improved homogeneity of the RF field (P = 0.00010.008) and subjective image quality (P < 0.0001) at each b value and also increased SNR. At lower and higher b value, the measured ADC of lateral left hepatic lobe and spleen between dual-source and single-source images were significantly different (P = 0.00010.047). At b = 0/500, there was no significant difference in ADC measurements between dual-source and single-source RF transmission for abdominal organs, except a slight statistically significant difference for spleen (P = 0.047). Conclusion: Parallel RF transmission significantly improved the image quality and homogeneity of the RF field. The RF transmission had a significant influence on measured ADC of lateral left hepatic lobe and spleen. At b = 0/500 the influence was minimum for all abdominal organs. J. Magn. Reson. Imaging 2013;37:875885. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:875 / 885
页数:11