Conventional versus computer-assisted surgery in total knee arthroplasty: comparison at ten years follow-up

被引:26
|
作者
d'Amato, Michele [1 ]
Ensini, Andrea [1 ,2 ]
Leardini, Alberto [2 ]
Barbadoro, Paolo [1 ]
Illuminati, Andrea [1 ]
Belvedere, Claudio [2 ,3 ]
机构
[1] Ist Ortoped Rizzoli, Dept Orthopaed Surg, IRCCS, Via Barbiano 1-10, I-40136 Bologna, Italy
[2] Ist Ortoped Rizzoli, Movement Anal Lab, IRCCS, Via Barbiano 1-10, I-40136 Bologna, Italy
[3] Ist Ortoped Rizzoli, Movement Anal Lab & Funct Clin Evaluat Prostheses, Ctr Ric Codivilla Putti, Via Barbiano 1-10, I-40136 Bologna, Italy
关键词
Total knee arthroplasty; Computer-aided surgery; Surgical navigation; Clinical outcome; Long-term follow-up; CONTROLLED-TRIAL; NAVIGATION; ALIGNMENT; OUTCOMES; OSTEOARTHRITIS; REPLACEMENTS; KINEMATICS; PROSTHESES; AXIS;
D O I
10.1007/s00264-018-4114-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
PurposeComputer-assisted systems (CAS) for total knee arthroplasty (TKA) were expected to result in more accurate prosthesis implantation, better patient outcomes, and longer implant survival when compared to conventional instrumentation (CI). The aim of this study was to compare two groups of patients operated using CAS or CI at ten years follow-up.MethodsOne hundred twenty TKA patients, 60 using CAS and 60 using CI, were contacted after a decade for follow-up. Eligible patients received radiological examination to assess the lower-limb mechanical axis. They were also clinically assessed using the Knee Injury and Osteoarthritis Outcome Score (KOOS) and the Knee Society Score for Knee (KSS-K) and Function (KSS-F) Scoring. Kaplan-Meier survival analysis was performed to assess revisions, not for post-traumatic reasons.ResultsIn CAS and CI groups, the lower-limb mechanical axis was 1.7 degrees 2.4 degrees and 1.5 degrees +/- 2.8 degrees, respectively; corresponding KOOS values were 82.3 +/- 14.3 and 78.6 +/- 14.4; KSS-K values were 85.9 +/- 11.1 and 85.0 +/- 9.7; KSS-F values were 82.2 +/- 19.3 and 83.8 +/- 18. For these assessments, the differences between the two groups were not statistically significant (p>0.05). Two CAS (3.8%) and three CI patients (5.7%) were revised. The Kaplan-Meier analysis showed no significant differences between the two groups.Conclusionsp id=Par4No significant differences were found at long-term follow-up in terms of radiographical-clinical outcomes and of implant survival between TKA operated using CAS or CI.
引用
收藏
页码:1355 / 1363
页数:9
相关论文
共 50 条
  • [41] Functional outcome after computer-assisted versus conventional total knee arthroplasty: a randomized controlled study
    Jörg Lützner
    Klaus-Peter Günther
    Stephan Kirschner
    Knee Surgery, Sports Traumatology, Arthroscopy, 2010, 18 : 1339 - 1344
  • [42] Computer-assisted total knee arthroplasty versus the conventional technique:: how precise is navigation in clinical routine?
    Tingart, Markus
    Luering, Christian
    Baethis, Holger
    Beckmann, Johannes
    Grifka, Joachim
    Perlick, Lars
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2008, 16 (01) : 44 - 50
  • [43] Computer-assisted total knee arthroplasty versus the conventional technique: how precise is navigation in clinical routine?
    Markus Tingart
    Christian Lüring
    Holger Bäthis
    Johannes Beckmann
    Joachim Grifka
    Lars Perlick
    Knee Surgery, Sports Traumatology, Arthroscopy, 2008, 16 : 44 - 50
  • [44] Functional outcome after computer-assisted versus conventional total knee arthroplasty: a randomized controlled study
    Luetzner, Joerg
    Guenther, Klaus-Peter
    Kirschner, Stephan
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2010, 18 (10) : 1339 - 1344
  • [45] The Cost-Effectiveness of Computer-Assisted Compared with Conventional Total Knee Arthroplasty
    Tian, Yao
    Ahmed, Abdalrahman G.
    Hiredesai, Annika N.
    Huang, Lynn Wei
    Patel, Ankita M.
    Ghomrawi, Hassan M. K.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2024, 106 (18): : 1680 - 1687
  • [46] Results of unicompartmental knee arthroplasty at a minimum of ten years of follow-up
    Berger, RA
    Meneghini, RM
    Jacobs, JJ
    Sheinkop, MB
    Della Valle, CJ
    Rosenberg, AG
    Galante, JO
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (05): : 999 - 1006
  • [47] Computer-assisted knee arthroplasty versus a conventional jig-based technique
    Langdown, AJ
    Auld, J
    Bruce, WJM
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (04): : 588 - 589
  • [48] Total knee arthroplasty with bicruciate preservation: Comparison versus the same posterostabilized design at eight years follow-up
    Goutallier, D.
    Manicom, O.
    Van Driessche, S.
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2008, 94 (06): : 585 - 595
  • [49] Total knee arthroplasty with computer-assisted navigation more closely replicates normal knee biomechanics than conventional surgery
    McClelland, Jodie A.
    Webster, Kate E.
    Ramteke, Alankar A.
    Feller, Julian A.
    KNEE, 2017, 24 (03): : 651 - 656
  • [50] Computer assisted navigation in total knee arthroplasty - Comparison with conventional methods
    Anderson, KC
    Buehler, KC
    Markel, DC
    JOURNAL OF ARTHROPLASTY, 2005, 20 (07): : 132 - 138