Comparison of Resins for Metal Oxide Affinity Chromatography with Mass Spectrometry Detection for the Determination of Phosphopeptides

被引:7
|
作者
Salovska, Barbora [1 ,3 ]
Tichy, Ales [1 ]
Fabrik, Ivo [2 ]
Rezacova, Martina [3 ]
Vavrova, Jirina [1 ]
机构
[1] Univ Def, Fac Mil Hlth Sci Hradec Kralove, Dept Radiobiol, Brno, Czech Republic
[2] Univ Def, Fac Mil Hlth Sci Hradec Kralove, Dept Mol Pathol, Brno, Czech Republic
[3] Charles Univ Prague, Fac Med Hradec Kralove, Inst Med Biochem, Prague, Czech Republic
关键词
Enrichment; Metal oxide affinity chromatography; Phosphoproteomics; Titanium dioxide; HYDROPHILIC-INTERACTION CHROMATOGRAPHY; TITANIUM-DIOXIDE; PHOSPHORYLATED PEPTIDES; ENRICHMENT STRATEGIES; SELECTIVE ISOLATION; ZIRCONIUM DIOXIDE; MS ANALYSIS; PHOSPHOPROTEINS; MS/MS; ACID;
D O I
10.1080/00032719.2013.773437
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Protein phosphorylation is a crucial regulatory mechanism in majority of biological processes. During MS, there is a general need to diminish suppression effect of non-phosphorylated peptides and counterbalance low abundance and insufficient ionization of phosphopeptides. Therefore, selective enrichment of their content in complex mixture has become an indispensable part of any phosphoproteomic study. In this work we employed metal oxide affinity chromatography (MOAC) approach. We have compared classic approach of mixing TiO2 and peptides in a microtube with microcolumns - commercial tips NuTips (TiO2/ZrO2 1:1) and TopTips (R) (TiO2, TiO2/ZrO2 1:1, and ZrO2). Selectivity of the given media towards phosphopeptides was tested on a tryptic digest of mixture of bovine proteins: /-casein and fetuin (phosphoproteins) with myoglobin and bovine serum albumin (non-phosphorylated proteins) in ratio 1:1:5:5 and 1:1:50:50, respectively. After enrichment, the obtained eluates were analyzed by tandem mass spectrometry (MALDI-TOF/TOF) on ABI 4800 in positive reflectron mode. To each media we applied four different protocols with different composition of loading and washing buffers and we compared efficiency of three displacers (1M lactic acid, 350mg/ml DHB, and 0.1M glutamic acid). In our settings, NuTips (R) proved as the most efficient media for analysis of low complex samples, since they exhibited the highest phosphoselectivity. Surprisingly, the Titansphere 5 mu m particles outperformed mixed TopTips, which against our expectations showed the lowest binding selectivity and reproducibility even after addition of three different displacers.
引用
收藏
页码:1505 / 1524
页数:20
相关论文
共 50 条
  • [31] Determination of Thiodiglycol and Its Oxide in Biomedical Samples by Gas Chromatography–Mass Spectrometry
    N. L. Koryagina
    E. I. Savel’eva
    N. S. Khlebnikova
    A. S. Radilov
    Journal of Analytical Chemistry, 2018, 73 : 1209 - 1216
  • [32] Liquid chromatography mass spectrometry for plant sterol oxide determination in complex mixtures
    Kemmo, Suvi
    Ollilainen, Velimatti
    Lampi, Anna-Maija
    Piironen, Vieno
    EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2008, 226 (06) : 1325 - 1334
  • [33] Liquid chromatography mass spectrometry for plant sterol oxide determination in complex mixtures
    Suvi Kemmo
    Velimatti Ollilainen
    Anna-Maija Lampi
    Vieno Piironen
    European Food Research and Technology, 2008, 226 : 1325 - 1334
  • [34] Simultaneous high-throughput determination of interaction kinetics for drugs and cyclodextrins by high performance affinity chromatography with mass spectrometry detection
    Wang, Caifen
    Wang, Xiaobo
    Xu, Xiaonan
    Liu, Botao
    Xu, Xu
    Sun, Lixin
    Li, Haiyan
    Zhang, Jiwen
    ANALYTICA CHIMICA ACTA, 2016, 909 : 75 - 83
  • [35] Determination of carbohydrates in tobacco products by liquid chromatography-mass spectrometry/mass spectrometry: A comparison with ion chromatography and application to product discrimination
    Clarke, MB
    Bezabeh, DZ
    Howard, CT
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2006, 54 (06) : 1975 - 1981
  • [36] Affinity chromatography as a method for sample preparation in gas chromatography/mass spectrometry
    Tsikas, D
    JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 2001, 49 (1-3): : 705 - 731
  • [37] DETERMINATION OF SERUM CORTISOL BY THERMOSPRAY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY - COMPARISON WITH GAS-CHROMATOGRAPHY MASS-SPECTROMETRY
    GASKELL, SJ
    ROLLINS, K
    SMITH, RW
    PARKER, CE
    BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1987, 14 (12): : 717 - 722
  • [38] Detection of phosphopeptides from complex mixtures using titanium oxide precolumns and FT-ICR mass spectrometry
    Pinkse, M.
    Heck, A.
    MOLECULAR & CELLULAR PROTEOMICS, 2005, 4 (08) : S281 - S281
  • [39] Qualitative and quantitative analysis of phosphopeptides with immobilized metal ion affinity chromatography enrichment, stable isotope labeling by amino acids in cell culture and nano-liquid chromatography-tandem mass spectrometry
    Zhang, Bo
    Liu, Xinghua
    Shi, Qinfang
    Liang, Qi
    Wu, Changyao
    Chen, Jianying
    ANALYTICAL METHODS, 2012, 4 (03) : 652 - 658
  • [40] Two-step immobilized metal affinity chromatography (IMAC) for phosphoproteomics using mass spectrometry
    Huang, SY
    Hsu, JL
    Chen, SH
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2005, 52 (04) : 765 - 772