Electrospray mass spectrometry of undiluted ionic liquids

被引:61
|
作者
Jackson, GP [1 ]
Duckworth, DC [1 ]
机构
[1] Oak Ridge Natl Lab, Div Chem Sci, Oak Ridge, TN 37831 USA
关键词
D O I
10.1039/b314754a
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Ionic liquids have been analyzed in undiluted form using electrospray mass spectrometry (ES-MS); results indicate that signal-to-noise ratios for minor constituents are comparable to those observed in conventional, diluted ES-MS and that this approach could be readily applied for mass spectrometric analysis of ionic liquids and ionic impurities/additives dissolved therein, especially those that are solvent reactive.
引用
收藏
页码:522 / 523
页数:2
相关论文
共 50 条
  • [31] The vapour of imidazolium-based ionic liquids: a mass spectrometry study
    Deyko, A.
    Lovelock, K. R. J.
    Licence, P.
    Jones, R. G.
    PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2011, 13 (37) : 16841 - 16850
  • [32] Mass Spectrometry of Ionic Liquids: ESI-MS/MS Studies
    Gupta, Gaurav R.
    Chaudhari, Ganesh R.
    Tomar, Preeti A.
    Gaikwad, Yogesh
    Rameez, Azad
    Pandya, Girish H.
    Waghulade, Govinda P.
    Patil, Kesharsingh J.
    ASIAN JOURNAL OF CHEMISTRY, 2013, 25 (15) : 8261 - 8265
  • [33] Electrospray ionization mass spectrometry
    Banks, JF
    Whitehouse, CM
    HIGH RESOLUTION SEPARATION AND ANALYSIS OF BIOLOGICAL MACROMOLECULES, PT A, 1996, 270 : 486 - 519
  • [34] Yttrium and europium separation by solvent extraction with undiluted thiocyanate ionic liquids
    Banda, Raju
    Forte, Federica
    Onghena, Bieke
    Binnemans, Koen
    RSC ADVANCES, 2019, 9 (09) : 4876 - 4883
  • [35] Microdevices for electrospray mass spectrometry
    Foret, F
    Liu, H
    Zhang, B
    Felten, C
    Karger, BL
    MICRO TOTAL ANALYSIS SYSTEMS '98, 2000, : 35 - 38
  • [36] Electrospray mass spectrometry of phospholipids
    Pulfer, M
    Murphy, RC
    MASS SPECTROMETRY REVIEWS, 2003, 22 (05) : 332 - 364
  • [37] Electrospray Ionization for Mass Spectrometry
    不详
    LC GC NORTH AMERICA, 2012, 30 (02) : 182 - 182
  • [38] Pulsed electrospray for mass spectrometry
    Lu, Y
    Zhou, F
    Shui, WQ
    Bian, LP
    Yang, PY
    ANALYTICAL CHEMISTRY, 2001, 73 (19) : 4748 - 4753
  • [39] The role of ionic liquids in co-catalysis of Baylis-Hillman reaction: Interception of supramolecular species via electrospray ionization mass spectrometry
    Santos, Leonardo Silva
    Neto, Brenno A. DaSilveira
    Consorti, Crestina S.
    Pavam, Cesar Henrique
    Almeida, Wanda P.
    Coelho, Fernando
    Dupont, Jairton
    Eberlin, Marcos N.
    JOURNAL OF PHYSICAL ORGANIC CHEMISTRY, 2006, 19 (11) : 731 - 736
  • [40] Structural analysis of ionic organotin(IV) compounds using electrospray tandem mass spectrometry
    Holcapek, M
    Kolárová, L
    Ruzicka, A
    Jambor, R
    Jandera, P
    ANALYTICAL CHEMISTRY, 2006, 78 (12) : 4210 - 4218