An active veto system consisting of plastic scintillation panels was installed outside the Pb shielding of a 115% n-type HPGe detector in an effort to reduce background continuum generated by cosmic ray muons on the surface. The Low Background Facility at the Lawrence Berkeley National Laboratory performs low level assay (generally of primordial U, Th, K) of candidate construction materials for experiments that require a high level of radiopurity. The counting is performed in two facilities: one local surface site and a remote underground site of approximately 600 m.w.e. For the recently installed veto system at the surface location, the top scintillator panel has been in use for nearly 1 year and the full 3 pi anticoincidence shield was commissioned into normal counting operations in January 2013. The integrated background from 20 to 3600 keV is reduced overall by a factor of 8, where most of the energy spectrum above 100 keV achieves an overall reduction that varies from 8 to 10. A dramatic improvement of peak-to-background across the entire continuum is observed, greatly enhancing low-level peaks that would otherwise be obscured. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:47 / 53
页数:7
相关论文
共 50 条
  • [31] A LOW-BACKGROUND SAMPLE CHANGER
    KOEPPE, P
    ATOMPRAXIS, 1967, 13 (08): : 354 - &
  • [32] EXTREMELY LOW-BACKGROUND BETA-GAMMA COINCIDENCE SPECTROMETER
    YAMAKOSHI, K
    NOGAMI, K
    NUCLEAR INSTRUMENTS & METHODS, 1976, 134 (03): : 519 - 524
  • [33] Ultra low-background gamma spectrometry for the monitoring of environmental neutrons
    Komura, K
    ENVIRONMENTAL RADIOCHEMICAL ANALYSIS II, 2003, (291): : 53 - 59
  • [34] Investigation of neutron shielding materials for low-background gamma spectrometry
    Khan, Abdul J.
    Li, Xin
    Haines, Douglas K.
    Hoffman, Timothy J.
    Semkow, Thomas M.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2021, 328 (03) : 941 - 950
  • [35] Investigation of neutron shielding materials for low-background gamma spectrometry
    Abdul J. Khan
    Xin Li
    Douglas K. Haines
    Timothy J. Hoffman
    Thomas M. Semkow
    Journal of Radioanalytical and Nuclear Chemistry, 2021, 328 : 941 - 950
  • [36] Gator: a low-background counting facility at the Gran Sasso Underground Laboratory
    Baudis, L.
    Ferella, A. D.
    Askin, A.
    Angle, J.
    Aprile, E.
    Bruch, T.
    Kish, A.
    Laubenstein, M.
    Manalaysay, A.
    Undagoitia, T. Marrodan
    Schumann, M.
    JOURNAL OF INSTRUMENTATION, 2011, 6
  • [37] LOW-BACKGROUND LARGE-APERTURE INFRARED MEASUREMENT FACILITY - PERFORMANCE
    MEIER, RH
    DAUGER, AB
    APPLIED OPTICS, 1978, 17 (22): : 3547 - 3554
  • [38] LOW-BACKGROUND TUNGSTEN FILAMENTS FOR SURFACE IONIZATION MASS SPECTROSCOPY
    FRAZER, JW
    BURNS, RP
    BARTON, GW
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1959, 30 (05): : 370 - 371
  • [39] An improved low-background cooled FET assembly for germanium spectroscopy
    Aalseth, CE
    Arthur, RJ
    Reeves, JH
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 378 - 381
  • [40] Detection of background thermal neutrons in a modified low-background germanium gamma-ray spectrometer
    Mietelski, Jerzy W.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2019, 322 (03) : 1331 - 1339