Secondary Orbital Reconstruction in Patients with Prior Orbital Fracture Repair

被引:29
|
作者
Kim, Jane S. [1 ]
Lee, Bradford W. [1 ]
Scawn, Richard L. [1 ]
Korn, Bobby S. [1 ]
Kikkawa, Don O. [1 ]
机构
[1] Univ Calif San Diego, Dept Ophthalmol, Shiley Eye Inst, Div Oculofacial Plast & Reconstruct Surg, La Jolla, CA 92093 USA
来源
关键词
BLOWOUT FRACTURES; FLOOR FRACTURES; DEFORMITIES; ENOPHTHALMOS; DIPLOPIA;
D O I
10.1097/IOP.0000000000000591
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate clinical characteristics, preoperative imaging findings, pre- and post-operative outcomes, and satisfaction of patients requiring secondary reconstruction after inadequate primary orbital fracture repair. Methods: Retrospective review of 13 patients requiring secondary orbital reconstruction following unsatisfactory primary repair. Primary outcomes were postoperative changes in enophthalmos, hypo-or hyper-globus, superior sulcus deformity, and restrictive strabismus. Secondary outcomes included patient satisfaction. Results: Of 13 patients, 9 patients had primary orbital implants, and 4 patients did not. Of the 9 with implants, 6 had inferior displacement posteriorly, 2 had superior displacement posteriorly, and 1 had good position but had entrapped orbital tissues beneath it. Findings from primary surgery included enophthalmos (12/13), hypoglobus (10/13), hyperglobus (1/13), superior sulcus deformity (9/13), restricted supraduction (12/13), and restricted infraduction (7/13). Mean preoperative enophthalmos and hypoglobus were 4.4 +/- 2.6 mm and 2.9 +/- 1.4 mm, respectively. Secondary reconstruction resulted in mean reduction of enophthalmos by 3.4 +/- 1.4 mm (p < 0.001), of hypoglobus by 2.9 +/- 1.5 mm (p < 0.001), and of hyperglobus by 1 mm (n = 1). All 9 patients had resolution of their superior sulcus deformity. Of 12 cases with restricted ocular motility, all had improvements in postoperative motility following secondary surgery. Mean improvement in supraduction and infraduction was 1.8 +/- 1.0 points (p < 0.001) and 1.4 +/- 1.3 points (p = 0.025), respectively. Twelve patients reported being very satisfied or satisfied with secondary surgery; 1 patient was neutral. Conclusions: This study demonstrates that secondary orbital reconstruction can achieve excellent functional and cosmetic results with high patient satisfaction and minimal complications. Secondary reconstruction of previously repaired orbital fractures should be considered when clinically indicated.
引用
收藏
页码:447 / 451
页数:5
相关论文
共 50 条
  • [21] Temporary Orbital Apex Syndrome after Repair of Orbital Wall Fracture
    Eo, SuRak
    Kim, John Y.
    Azari, Kodi
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2005, 116 (05) : 85E - 89E
  • [22] Nylon Foil ( Supramid) Orbital Implants in Pediatric Orbital Fracture Repair
    Timoney, Peter J.
    Krakauer, Mark
    Wilkes, Byron N.
    Lee, H. B. Harold
    Nunery, William R.
    OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 2014, 30 (03): : 212 - 214
  • [23] Orbital Implants in Orbital Fracture Reconstruction: A Ten-Year Series
    Seen, Sophia
    Young, Stephanie
    Lang, Stephanie S.
    Lim, Thiam-Chye
    Amrith, Shantha
    Sundar, Gangadhara
    CRANIOMAXILLOFACIAL TRAUMA & RECONSTRUCTION, 2021, 14 (01) : 56 - 63
  • [24] SECONDARY RECONSTRUCTION OF POSTTRAUMATIC ORBITAL DEFORMITIES
    WHITAKER, LA
    YAREMCHUK, MJ
    ANNALS OF PLASTIC SURGERY, 1990, 25 (06) : 440 - 449
  • [25] Secondary Orbital Implant Insertion in an Anophthalmic Patient after Orbital Reconstruction
    Arvanitis, P.
    Stratoudakis, A.
    Alexandrou, C.
    ORBIT-THE INTERNATIONAL JOURNAL ON ORBITAL DISORDERS-OCULOPLASTIC AND LACRIMAL SURGERY, 2007, 26 (04): : 275 - 277
  • [26] Customized orbital implant versus 3D preformed titanium mesh for orbital fracture repair: A retrospective comparative analysis of orbital reconstruction accuracy
    Consorti, Giuseppe
    Betti, Enrico
    Catarzi, Lisa
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2024, 52 (04) : 532 - 537
  • [27] Orbital Hematoma Caused by Bleeding From Orbital Branch of the Infraorbital Artery After Reconstruction of an Orbital Fracture
    Hwang, Kun
    Kim, Joo Ho
    Kang, Young Hye
    JOURNAL OF CRANIOFACIAL SURGERY, 2014, 25 (02) : 375 - 376
  • [28] COMPLEX ORBITAL FRACTURE REPAIR USING RIGID FIXATION OF THE INTERNAL ORBITAL SKELETON
    RUBIN, PAD
    SHORE, JW
    YAREMCHUK, MJ
    OPHTHALMOLOGY, 1992, 99 (04) : 553 - 559
  • [29] Reconstruction of the orbital wall using superior orbital rim osteotomy in a patient with a superior orbital wall fracture
    Heo J.J.
    Chong J.-H.
    Han J.J.
    Jung S.
    Kook M.-S.
    Oh H.-K.
    Park H.-J.
    Maxillofacial Plastic and Reconstructive Surgery, 40 (1)
  • [30] Orbital Reconstruction Using a Polyetheretherketone Patient-Specific Implant After Removal of a Mucocele Developing After Orbital Fracture Repair
    Lee, Junho
    Choi, Young Jae
    Rha, Eun Young
    JOURNAL OF CRANIOFACIAL SURGERY, 2023, 34 (08) : 2321 - 2322