Usefulness of spectral computed tomography for evaluation of intestinal activity and severity in ileocolonic Crohn's disease

被引:23
|
作者
Peng, Jiang Chen [1 ]
Feng, Qi [2 ]
Zhu, Jiong [2 ]
Shen, Jun [1 ]
Qiao, Yu Qi [1 ]
Xu, Jian Rong [2 ]
Ran, Zhi Hua [1 ]
机构
[1] Shanghai Jiao Tong Univ, Shanghai Inst Digest Dis, Div Gastroenterol & Hepatol, Minist Hlth,Ren Ji Hosp,Sch Med,Key Lab Gastroent, 145 Middle Shandong Rd, Shanghai 200001, Peoples R China
[2] Shanghai Jiao Tong Univ, Sch Med, Dept Radiol, Ren Ji Hosp, Shanghai, Peoples R China
基金
美国国家科学基金会;
关键词
ileocolonic Crohn's disease; lambda(HU); normalized iodine concentration; spectral CT; LESIONS CHARACTERIZATION; MULTIDETECTOR CT; DIFFERENTIATION; ENTEROGRAPHY; ATTENUATION;
D O I
10.1177/1756283X16668309
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: Assessment of intestinal activity and severity of Crohn's disease (CD) is crucial to guide treatment. In this study, we aimed to investigate the accuracy of spectral computed tomography (CT) in this assessment and make a comparison with conventional CT. Methods: A total of 50 patients with ileocolonic CD underwent spectral CT scanning. Conventional CT and spectral CT images were reconstructed. Endoscopic lesions were classified as absent, mild lesions and severe lesions. Qualitative and quantitative findings in CT images were compared in these segments. Logistic regressions were established, based on conventional and spectral CT parameters, to predict intestinal activity and severity. Comparisons were made by receiver operating characteristic (ROC) curve. Results: The results showed that bowel wall hyperenhancement, ulcers on CT images, comb sign, bowel wall thickness, normalized iodine concentration (NIC) and slope of HU curve (lambda(HU)) increased significantly (p < 0.01) with endoscopic severity. In predicting intestinal activity, spectral CT demonstrated higher accuracy (99.6% versus 94.7%), sensitivity (99.1% versus 93.4%) and specificity (99.9% versus 94.4%) than conventional CT. In predicting intestinal severity, spectral CT also had higher accuracy (96.5% versus 91.9%), sensitivity (96.5% versus 92.1%) and specificity (95.8% versus 89.8%) than conventional CT. Besides, both NIC and lambda(HU) correlated significantly with Simple Endoscopic Score for CD (r = 0.833 and r = 0.771; both p < 0.001), but their correlations with C-reactive protein (r = 0.578 and r = 0.513; both p < 0.01) and Harvey-Bradshaw Index (r = 0.545 and r = 0.522; both p < 0.01) were moderate. Conclusions: Compared with conventional CT, spectral CT had higher accuracy in detecting intestinal activity and severity of CD, which could be an alternative choice in evaluation of CD.
引用
收藏
页码:795 / 805
页数:11
相关论文
共 50 条
  • [31] Crohn’s disease: prevalence of intestinal and extraintestinal manifestations detected by computed tomography enterography with water enema
    F. Paparo
    L. Bacigalupo
    I. Garello
    E. Biscaldi
    M. A. Cimmino
    E. Marinaro
    G. A. Rollandi
    Abdominal Imaging, 2012, 37 : 326 - 337
  • [32] Crohn's disease: prevalence of intestinal and extraintestinal manifestations detected by computed tomography enterography with water enema
    Paparo, F.
    Bacigalupo, L.
    Garello, I.
    Biscaldi, E.
    Cimmino, M. A.
    Marinaro, E.
    Rollandi, G. A.
    ABDOMINAL IMAGING, 2012, 37 (03): : 326 - 337
  • [33] A Preliminary Study on the Feasibility of the Quantitative Parameters of Dual-Energy Computed Tomography Enterography in the Assessment of the Activity of Intestinal Crohn's Disease
    Xiao, Wei-xiong
    Zhu, Yu-ting
    Zhang, Zhi-chao
    Luo, Min
    Ma, Ming-ping
    INTERNATIONAL JOURNAL OF GENERAL MEDICINE, 2021, 14 : 7051 - 7058
  • [34] Making computed tomography safer for patients with Crohn's disease
    O'Grady, John
    Carey, Brian W.
    Kavanagh, Richard G.
    O'Connell, Aislinn
    O'Connor, Owen J.
    Kenny-Walsh, Elizabeth
    Zulquernain, Syed A.
    Maher, Michael M.
    Shanahan, Fergus
    SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 2022, 57 (02) : 175 - 182
  • [35] Structured Reporting of Computed Tomography Enterography in Crohn's Disease
    Zhu, Hui
    Chen, Suying
    Chen, Jinghao
    Yang, Jushun
    Cong, Ruochen
    Sun, Jinjie
    Xu, Yachun
    He, Bosheng
    CURRENT MEDICAL IMAGING, 2024, 20
  • [36] Usefulness of Intestinal Ultrasound to Detect Small Intestinal Stenosis in Patients with Crohn's Disease
    Takeuchi, Keiko
    Inokuchi, Toshihiro
    Takahara, Masahiro
    Ohmori, Masayasu
    Yasutomi, Eriko
    Oka, Shohei
    Igawa, Shoko
    Takei, Kensuke
    Baba, Yuki
    Kawano, Seiji
    Yamasaki, Yasushi
    Kinugasa, Hideaki
    Harada, Keita
    Hiraoka, Sakiko
    Okada, Hiroyuki
    JOURNAL OF ULTRASOUND IN MEDICINE, 2023, 42 (02) : 373 - 383
  • [37] Usefulness of ultrasonography for small intestinal evaluations in pediatric Crohn's disease
    Okuhira, Takeru
    Yoden, Atsushi
    Kaji, Emiri
    Otani-Akamatsu, Masano
    Inoue, Keisuke
    Aomatsu, Tomoki
    Takitani, Kimitaka
    Ashida, Akira
    PEDIATRICS INTERNATIONAL, 2022, 64 (01)
  • [38] COMPUTED-TOMOGRAPHY IN CROHN DISEASE
    FRAGER, DH
    GOLDMAN, M
    BENEVENTANO, TC
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1983, 7 (05) : 819 - 824
  • [39] Computed tomography enterography and small bowel ultrasound in assessing ileal Crohn's disease activity
    Losco, Alessandra
    Trattenero, Chiara
    Fraquelli, Mirella
    Forzenigo, Laura Virginia
    Massironi, Sara
    Pirola, Lorena
    Conte, Dario
    Biondetti, Pietro
    Basilisco, Guido
    GASTROENTEROLOGY, 2008, 134 (04) : A204 - A204
  • [40] Balloon dilation of ileocolonic strictures in Crohn's disease
    Saunders, BP
    Brown, GJE
    Lemann, M
    Rutgeerts, P
    ENDOSCOPY, 2004, 36 (11) : 1001 - 1007