Real-time detection of fatigue effect on active muscle hemodynamics using diffuse correlation spectroscopy

被引:2
|
作者
Nozaki, K. [1 ]
Nakabayashi, M. [1 ]
Ichinose, M. [2 ]
Ono, Y. [1 ,3 ]
机构
[1] Meiji Univ, Elect Engn Program, Grad Sch Sci & Technol, Kawasaki, Kanagawa, Japan
[2] Meiji Univ, Sch Business Adm, Human Integrat Physiol Lab, Tokyo, Japan
[3] Meiji Univ, Sch Sci & Technol, Dept Elect & Bioinformat, Kawasaki, Kanagawa, Japan
关键词
diffuse correlation spectroscopy; muscle fatigue; muscle hemodynamics; BLOOD-FLOW; METABOLISM; CONTRACTIONS; EMG;
D O I
10.1117/12.2542876
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The effect of fatigue on the hemodynamic responses of active skeletal muscle has yet to be fully understood due to the limited evaluation techniques of deep tissues hemodynamics We adopted diffuse correlation spectroscopy (DCS), a promising optical imaging technique of tissue blood flow velocity, to determine fatigue-related changes in blood flow and vascular conductance of active muscle. Hemodynamic and electrophysiological responses of the flexor digitorum superficialis were continuously monitored by DCS and electromyogram (EMG) from the non-dominant forearm of young-adult participants (n=12). Systemic blood pressure was monitored from the other side of upper arm every minute. Participants performed 2 minutes of dynamic handgrip exercise (with a duty cycle of 2-s contraction and 2-s relaxation) with the load of 10% or 30% of maximal voluntary contraction (MVC) twice. To induce muscle fatigue, static handgrip (40% MVC for 2 minutes) was performed between the two sessions of dynamic handgrip exercise. Induction of fatigue was confirmed by significant decreases of EMG mean frequency in both load conditions. Muscle fatigue induced significant increase of active muscle blood flow and mean blood pressure in both load conditions. Vascular conductance of active muscle showed tendency of (10% MVC) or significant (30% MVC) increase after fatigue induction. These results suggest the enhanced vasodilatation along with fatigue in active muscles, possibly derived by accumulated metabolic and vasodilator substances. Our results demonstrate the possible application of DCS to detect and evaluate the fatigue effect of active skeletal muscle.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] In situ electromagnet with active cooling for real-time magneto-optic Kerr effect spectroscopy
    Brozyniak, A.
    Mendirek, G.
    Hohage, M.
    Navarro-Quezada, A.
    Zeppenfeld, P.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2021, 92 (02):
  • [42] Characterization of a hybrid diffuse correlation spectroscopy and time-resolved near-infrared spectroscopy system for real-time monitoring of cerebral blood flow and oxygenation
    Verdecchia, K.
    Diop, M.
    Lee, A.
    St Lawrence, K.
    ADVANCED BIOMEDICAL AND CLINICAL DIAGNOSTIC AND SURGICAL GUIDANCE SYSTEMS XIII, 2015, 9313
  • [43] Real-Time Hand Gesture Recognition Using the Myo Armband and Muscle Activity Detection
    Benalcazar, Marco E.
    Motoche, Cristhian
    Zea, Jonathan A.
    Jaramillo, Andres G.
    Anchundia, Carlos E.
    Zambrano, Patricio
    Segura, Marco
    Benalcazar Palacios, Freddy
    Perez, Maria
    2017 IEEE SECOND ECUADOR TECHNICAL CHAPTERS MEETING (ETCM), 2017,
  • [44] Real-time hand gesture detection and recognition using boosted classifiers and active learning
    Francke, Hardy
    Ruiz-Del-Solar, Javier
    Verschae, Rodrigo
    ADVANCES IN IMAGE AND VIDEO TECHNOLOGY, PROCEEDINGS, 2007, 4872 : 533 - 547
  • [45] Real-time imaging of muscle oxygenation using spatially resolved near-infrared spectroscopy
    Kek, KJ
    Samizo, M
    Kudo, N
    Yamamoto, K
    APBP 2004: SECOND ASIAN AND PACIFIC RIM SYMPOSIUM ON BIOPHOTONICS, PROCEEDINGS, 2004, : 30 - 31
  • [46] Real-time analysis of intrusion detection alerts via correlation
    Lee, Soojin
    Chung, Byungchun
    Kim, Heeyoul
    Lee, Yunho
    Park, Chanil
    Yoon, Hyunsoo
    COMPUTERS & SECURITY, 2006, 25 (03) : 169 - 183
  • [47] Real-time pedestrian detection using eigenflow
    Goel, Dhiraj
    Chen, Tsuhan
    2007 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, VOLS 1-7, 2007, : 1357 - 1360
  • [48] Real-time monitoring of active ingredient dispersion in a pharmaceutical aqueous suspension using Raman spectroscopy
    Pu, Yu
    Medendorp, Joseph P.
    Yonzon, Chanda R.
    JOURNAL OF RAMAN SPECTROSCOPY, 2011, 42 (11) : 1994 - 1999
  • [49] Real-time Pedestrian Detection Using OpenCL
    Sun, Rong
    Wang, Xuzhi
    Ye, Xuannan
    2014 INTERNATIONAL CONFERENCE ON AUDIO, LANGUAGE AND IMAGE PROCESSING (ICALIP), VOLS 1-2, 2014, : 401 - 404
  • [50] Using real-time PCR for pathogen detection
    Johnson, M
    Brzoska, P
    Petrauskene, O
    Melancon, C
    GENETIC ENGINEERING NEWS, 2005, 25 (14): : 40 - +