An amperometric biosensor based on laccase immobilized onto MnO2NPs/cMWCNT/PANI modified Au electrode

被引:20
|
作者
Rawal, Rachna [1 ]
Chawla, Sheetal [1 ]
Malik, Poonam [1 ]
Pundir, C. S. [1 ]
机构
[1] Maharshi Dayanand Univ, Dept Biochem, Rohtak 124001, Haryana, India
关键词
Phenolic compounds; Laccase; Amperometric biosensor; Ganoderma sp; MnO2; NPs; cMWCNT; PLATINUM NANOPARTICLES; PHENOLS;
D O I
10.1016/j.ijbiomac.2011.11.022
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A method is described for construction of an amperometric biosensor for detection of phenolic compounds based on covalent immobilization of laccase (Lac) onto manganese dioxide nanoparticles (MnO(2)NPs) decorated carboxylated multiwalled carbon nanotubes (cMWCNTs)/PANI composite electrodeposited onto a gold (Au) electrode through N-ethyl-N'-(3-dimethylaminopropyl) carbodiimide (EDC) and N-hydroxy succinimide (NHS) chemistry. The modified electrode was characterized by scanning electron microscopy (SEM), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The biosensor showed optimum response at pH 5.5 (0.1 M sodium acetate buffer) and 35 degrees C, when operated at 0.3 V vs. Ag/AgCl. Linear range, response time, detection limit were 0.1-10 mu M (lower concentration range) and 10-500 mu M (higher concentration range), 4s and 0.04 mu M, respectively. Biosensor measured total phenolic content in tea leaves extract. The enzyme electrode was used 150 times over a period of 5 months. (c) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:175 / 181
页数:7
相关论文
共 50 条
  • [41] A glucose biosensor based on direct electrochemistry of glucose oxidase immobilized onto platinum nanoparticles modified graphene electrode
    Liu AiRong
    Huang ShiMing
    SCIENCE CHINA-PHYSICS MECHANICS & ASTRONOMY, 2012, 55 (07) : 1163 - 1167
  • [42] A glucose biosensor based on direct electrochemistry of glucose oxidase immobilized onto platinum nanoparticles modified graphene electrode
    AiRong Liu
    ShiMing Huang
    Science China Physics, Mechanics and Astronomy, 2012, 55 : 1163 - 1167
  • [43] An amperometric hydrogen peroxide biosensor based on a hemoglobin-immobilized dopamine-oxidation polymer/Prussian blue/Au electrode
    Li, Mingrui
    Deng, Chunyan
    Chen, Chao
    Peng, Limei
    Ning, Guohong
    Xie, Qingji
    Yao, Shouzhuo
    ELECTROANALYSIS, 2006, 18 (22) : 2210 - 2217
  • [44] Fabrication of an amperometric tyramine biosensor based on immobilization of tyramine oxidase on AgNPs/l-Cys-modified Au electrode
    Batra, Bhawna
    Lata, Suman
    Devi, Rooma
    Yadav, Sandeep
    Pundir, Chandra Shekhar
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2012, 16 (12) : 3869 - 3876
  • [45] Fabrication of an amperometric tyramine biosensor based on immobilization of tyramine oxidase on AgNPs/l-Cys-modified Au electrode
    Bhawna Batra
    Suman Lata
    Rooma Devi
    Sandeep Yadav
    Chandra Shekhar Pundir
    Journal of Solid State Electrochemistry, 2012, 16 : 3869 - 3876
  • [46] Amperometric nitric oxide biosensor based on the immobilization of hemoglobin on a nanometer-sized gold colloid modified Au electrode
    Gu, HY
    Yu, AM
    Yuan, SS
    Chen, HY
    ANALYTICAL LETTERS, 2002, 35 (04) : 647 - 661
  • [47] Ascorbic acid biosensor based on laccase immobilized on an electrode modified with a self-assembled monolayer and coated with functionalized quantum dots
    Wang, Zhan
    Xu, Qiao
    Wang, Jian-Hao
    Yang, Qin
    Yu, Jiu-Hong
    Zhao, Yuan-Di
    MICROCHIMICA ACTA, 2009, 165 (3-4) : 387 - 392
  • [48] Ascorbic acid biosensor based on laccase immobilized on an electrode modified with a self-assembled monolayer and coated with functionalized quantum dots
    Zhan Wang
    Qiao Xu
    Jian-Hao Wang
    Qin Yang
    Jiu-Hong Yu
    Yuan-Di Zhao
    Microchimica Acta, 2009, 165 : 387 - 392
  • [49] A Mediator-Free Bienzyme Amperometric Biosensor Based on Horseradish Peroxidase and Glucose Oxidase Immobilized on Carbon Nanotube Modified Electrode
    Yao, Yan-Li
    Shiu, Kwok-Keung
    ELECTROANALYSIS, 2008, 20 (19) : 2090 - 2095
  • [50] Direct Electrochemistry of Catalase Immobilized at Electrochemically Reduced Graphene Oxide Modified Electrode for Amperometric H2O2 Biosensor
    Ting, Shan Wei
    Periasamy, Arun Prakash
    Chen, Shen-Ming
    Saraswathi, R.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2011, 6 (10): : 4438 - 4453