T2-weighted IDEAL fast spin echo imaging of the brachial plexus: comparison with STIR

被引:10
|
作者
Tomura, Noriaki [1 ]
Saginoya, Toshiyuki [1 ]
Kokubun, Mika [1 ]
Tsuchiya, Mario [1 ]
Yamamoto, Teiji [1 ]
机构
[1] Southern Tohoku Gen Hosp, Res Inst Neurosci, Dept Radiol & Neurol, Koriyama, Fukushima 9638563, Japan
关键词
Brachial plexus; magnetic resonance imaging (MRI); IDEAL; STIR; WATER-FAT SEPARATION; MR NEUROGRAPHY;
D O I
10.1177/0284185114552292
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Short TI inversion-recovery (STIR) imaging is widely used, but its signal-to-noise-ratio (SNR) is relatively low. Iterative decomposition of water and fat with echo asymmetric and least-squares estimation (IDEAL) imaging has demonstrated promising results in several areas. Purpose To compare T2-weighted fast spin-echo IDEAL (T2W IDEAL-FSE) with STIR to determine which sequence is superior to image the brachial plexus. Material and Methods The brachial plexus was imaged in 18 patients and six volunteers. The patients' diseases comprised of: suspected chronic inflammatory demyelinating polyneuropathy (CIDP), brachial plexus palsy of unknown origin, and suspected amyotrophic lateral sclerosis. Frontal partial MIP images were acquired. Image quality was qualitatively and independently scored by two radiologists on a three-point grading scale for noise, visibility of the nerve roots, and overall image quality. Inter-observer agreement of the rating by two readers was assessed. The SNR and contrast-to-noise-ratio (CNR) were quantitatively calculated, and differences between T2W IDEAL-FSE and STIR were compared. Results Qualitatively, each score for T2W IDEAL-FSE was significantly higher (P<0.01) than that for STIR. Quantitatively, both SNR and CNR for T2W IDEAL-FSE (45.312.6 and 27.1 +/- 12.1, respectively) were significantly higher (P<0.001) than those for STIR (17.4 +/- 6.1 and 8.2 +/- 4.7, respectively). Conclusion T2W IDEAL-FSE could be used to replace STIR for visualization of the brachial plexus.
引用
收藏
页码:1242 / 1247
页数:6
相关论文
共 50 条
  • [21] Postoperative sella: Evaluation with fast spin echo T2-weighted high-resolution imaging
    Nakasu, Y
    Itoh, R
    Nakasu, S
    Nioka, H
    Kidooka, M
    Handa, J
    NEUROSURGERY, 1998, 43 (03) : 440 - 446
  • [22] T2-WEIGHTED MR-IMAGING OF THE ABDOMEN - FAST SPIN-ECHO VS CONVENTIONAL SPIN-ECHO SEQUENCES
    CATASCA, JV
    MIROWITZ, SA
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (01) : 61 - 67
  • [24] Comparison of T2-weighted MRI single-shot fast spin echo and fast spin echo sequences in focal hepatic lesion detection
    Gras, E
    Aube, C
    Tanguy, J
    Oberti, F
    Burtin, P
    Caron, C
    RADIOLOGY, 2000, 217 : 168 - 169
  • [25] FAST SPIN-ECHO INVERSION-RECOVERY IMAGING VERSUS FAST T2-WEIGHTED SPIN-ECHO IMAGING IN BONE-MARROW ABNORMALITIES
    HILFIKER, P
    ZANETTI, M
    DEBATIN, JF
    MCKINNON, G
    HODLER, J
    INVESTIGATIVE RADIOLOGY, 1995, 30 (02) : 110 - 114
  • [26] T2-weighted MR imaging of prostate cancer: multishot echo-planar imaging vs fast spin-echo imaging
    Tamada, T
    Sone, T
    Nagai, K
    Jo, Y
    Gyoten, M
    Imai, S
    Kajihara, Y
    Fukunaga, M
    EUROPEAN RADIOLOGY, 2004, 14 (02) : 318 - 325
  • [27] T2-weighted MR imaging of prostate cancer: multishot echo-planar imaging vs fast spin-echo imaging
    Tsutomu Tamada
    Teruki Sone
    Kiyohisa Nagai
    Yoshimasa Jo
    Masayuki Gyoten
    Shigeki Imai
    Yasumasa Kajihara
    Masao Fukunaga
    European Radiology, 2004, 14 : 318 - 325
  • [28] Evaluation of focal liver lesions: fast-recovery fast spin echo T2-weighted MR imaging
    Akin, Oguz
    Schwartz, Lawrence H.
    Welber, Adam
    Maier, Cynthia F.
    DeCorato, Douglas R.
    Panicek, David M.
    CLINICAL IMAGING, 2006, 30 (05) : 322 - 325
  • [29] APPLICATION OF FAST SPIN-ECHO T(2)-WEIGHTED IMAGING FOR EXAMINATION OF THE NEUROCRANIUM - COMPARISON WITH THE CONVENTIONAL T(2)-WEIGHTED SPIN-ECHO SEQUENCE
    SIEWERT, C
    HOSTEN, N
    FELIX, R
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1994, 161 (01): : 44 - 50
  • [30] T2-weighted MRI of the uterus: Fast spin echo vs. breath-hold fast spin echo
    Ascher, SM
    O'Malley, J
    Semelka, RC
    Patt, RH
    Rajan, S
    Thomasson, D
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1999, 9 (03): : 384 - 390