Effects of stimulation rate, mode and level on modulation detection by cochlear implant users

被引:83
|
作者
Galvin, JJ [1 ]
Fu, QJ [1 ]
机构
[1] House Ear Res Inst, Dept Auditory Implants & Percept, Los Angeles, CA 90057 USA
关键词
modulation detection threshold; stimulation rate; stimulation mode; stimulation level; temporal cues;
D O I
10.1007/s10162-005-0007-6
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
In cochlear implant (CI) patients, temporal processing is often poorest at low listening levels, making perception difficult for low-amplitude temporal cues that are important for consonant recognition and/or speech perception in noise. It remains unclear how speech processor parameters such as stimulation rate and stimulation mode may affect temporal processing, especially at low listening levels. The present study investigated the effects of these parameters on modulation detection by six CI users. Modulation detection thresholds (MDTs) were measured as functions of stimulation rate, mode, and level. Results show that for all stimulation rate and mode conditions, modulation sensitivity was poorest at quiet listening levels, consistent with results from previous studies. MDTs were better with the lower stimulation rate, especially for quiet-to-medium listening levels. Stimulation mode had no significant effect on MDTs. These results suggest that, although high stimulation rates may better encode temporal information and widen the electrode dynamic range, CI patients may not be able to access these enhanced temporal cues, especially at the lower portions of the dynamic range. Lower stimulation rates may provide better recognition of weak acoustic envelope information.
引用
收藏
页码:269 / 279
页数:11
相关论文
共 50 条
  • [41] Electroacoustic verification of frequency modulation systems in cochlear implant users
    Destro Fidencio, Vanessa Luisa
    de Souza Jacob, Regina Tangerino
    Tanamati, Liege Franzini
    Bucuvic, Erika Cristina
    Mortari Moret, Adriane Lima
    BRAZILIAN JOURNAL OF OTORHINOLARYNGOLOGY, 2019, 85 (02) : 162 - 169
  • [42] Spectral loudness summation for electrical stimulation in cochlear implant users
    Theelen-van den Hoek, Femke L.
    Boymans, Monique
    Dreschler, Wouter A.
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2015, 54 (11) : 818 - 827
  • [43] Modulation detection interference in cochlear implant subjects
    Richardson, LM
    Busby, PA
    Clark, GM
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1998, 104 (01): : 442 - 452
  • [44] Frequency modulation detection in cochlear implant subjects
    Chen, HB
    Zeng, FG
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2004, 116 (04): : 2269 - 2277
  • [45] Effects of pulse rate and electrode array design on intensity discrimination in cochlear implant users
    Kreft, HA
    Donaldson, GS
    Nelson, DA
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2004, 116 (04): : 2258 - 2268
  • [46] Influence of Speech Rate on Auditory Recognition in Cochlear Implant Users
    de Sousa, Aline Faria
    da Costa, Lucas Bevilacqua Alves
    Costa, Maristela Julio
    Brito Neto, Rubens, V
    AUDIOLOGY AND NEUROTOLOGY, 2024, 29 (06) : 480 - 486
  • [47] Effect of Pulse Rate on Loudness Discrimination in Cochlear Implant Users
    Azadpour, Mahan
    McKay, Colette M.
    Svirsky, Mario A.
    JARO-JOURNAL OF THE ASSOCIATION FOR RESEARCH IN OTOLARYNGOLOGY, 2018, 19 (03): : 287 - 299
  • [48] Effect of Pulse Rate on Loudness Discrimination in Cochlear Implant Users
    Mahan Azadpour
    Colette M. McKay
    Mario A. Svirsky
    Journal of the Association for Research in Otolaryngology, 2018, 19 : 287 - 299
  • [49] Enhancement of interaural level differences for bilateral cochlear implant users
    Gajecki, Tom
    Nogueira, Waldo
    HEARING RESEARCH, 2021, 409
  • [50] Effects of stimulation rates on Cantonese lexical tone perception by cochlear implant users in Hong Kong
    Au, DKK
    CLINICAL OTOLARYNGOLOGY, 2003, 28 (06): : 533 - 538