A simple mathematical model for the resonance frequency analysis of dental implant stability: Implant clamping quotient

被引:4
|
作者
Argatov, Ivan [1 ]
Iantchenko, Alexei [2 ]
机构
[1] Tech Univ Berlin, Inst Mech, D-10623 Berlin, Germany
[2] Malmo Univ, Fac Technol & Soc, Dept Mat Sci & Appl Math, SE-20506 Malmo, Sweden
关键词
Resonance frequency analysis; Dental implant; Implant micromobility; Implant stability quotient;
D O I
10.1016/j.mechrescom.2018.12.004
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
A simple mathematical model for free vibrations of an elastically clamped beam is suggested to interpret the results of the resonance frequency analysis developed for implant stability measurements in terms of the Implant Stability Quotient (ISQ) units. It is shown that the resonance frequency substantially depends on the lateral compliance of the implant/bone system. Based on the notion of the lateral stiffness of the implant/bone system, a new measure of the implant stability is introduced in the form similar to the ISQ scale and is called the Implant Clamping Quotient (ICQ), because it characterizes the jawbone's clamp of the implant. By definition, the ICQ unit is equal to a percentage of the original scale for the lateral stiffness of the implant/bone system. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:67 / 70
页数:4
相关论文
共 50 条
  • [31] Correlation Between Implant Stability Quotient and Percussion Sound Frequency
    Peeraprasompong, Wansiri
    Aunmeungtong, Weerapan
    Khongkhunthian, Pathawee
    CLINICAL AND EXPERIMENTAL DENTAL RESEARCH, 2024, 10 (04):
  • [32] Computational simulation of dental implant osseointegration through resonance frequency analysis
    Perez, M. A.
    Moreo, P.
    Garcia-Aznar, J. M.
    Doblare, M.
    JOURNAL OF BIOMECHANICS, 2008, 41 (02) : 316 - 325
  • [33] Associations of Resonance Frequency Analysis with Dynamic Mechanical Analysis of Dental Implant Systems
    Kim, Do-Gyoon
    Kwon, Hyun-Jung
    Jeong, Yong-Hoon
    Chien, Hua-Hong
    Crance, Samantha
    Agnew, Amanda M.
    Battula, Suneel
    Lee, Jin Whan
    Wen, Hai Bo
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2016, 18 (02) : 332 - 341
  • [34] Insertion torque and resonance frequency analysis of dental implant systems in an animal model with loaded implants
    Al-Nawas, Bilal
    Wagner, Wilfried
    Groetz, Knut A.
    IMPLANTOLOGIE, 2008, 16 (01): : 11 - 20
  • [35] Insertion torque and resonance frequency analysis of dental implant systems in an animal model with loaded implants
    Al-Nawas, Bilal
    Wagner, Wilfried
    Groetz, Knut A.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2006, 21 (05) : 726 - 732
  • [36] An examination of immediately loaded dental implant stability in the diabetic patient using resonance frequency analysis (RFA)
    Balshi, Stephen F.
    Wolfinger, Glenn J.
    Balshi, Thomas J.
    QUINTESSENCE INTERNATIONAL, 2007, 38 (04): : 271 - 279
  • [37] Implant stability quotient and osteogenic process in dental implant sites prepared using piezoelectric technique: A study in minipigs
    Schierano, Gianmario
    Baldi, Domenico
    Peirone, Bruno
    von Degerfeld, Mitzy Mauthe
    Modica, Fabio
    Notaro, Vincenzo
    Boretto, Cecilia
    Muzio, Giuliana
    Autelli, Riccardo
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2025,
  • [38] Resonance frequency assessment of dental implant stability with various bone qualities: a numerical approach
    Huang, HM
    Lee, SY
    Yeh, CY
    Lin, CT
    CLINICAL ORAL IMPLANTS RESEARCH, 2002, 13 (01) : 65 - 74
  • [39] Measurement of mini-implant stability using resonance frequency analysis
    Nienkemper, Manuel
    Wilmes, Benedict
    Panayotidis, Agamemnon
    Pauls, Alexander
    Golubovic, Vladimir
    Schwarz, Frank
    Drescher, Dieter
    ANGLE ORTHODONTIST, 2013, 83 (02) : 230 - 238
  • [40] Comparison of Resonance Frequency Analysis and of Quantitative Ultrasound to Assess Dental Implant Osseointegration
    Vayron, Romain
    Vu-Hieu Nguyen
    Lecuelle, Benoit
    Lomami, Hugues Albini
    Meningaud, Jean-Paul
    Bosc, Romain
    Haiat, Guillaume
    SENSORS, 2018, 18 (05)