Design and evaluation of a single-pivot supported centrifugal blood pump

被引:11
|
作者
Yoshino, M
Uemura, T
Takahashi, T
Watanabe, T
Hoshi, H
Ohuchi, K
Nakamura, M
Fujita, H
Sakamoto, T
Takatani, S
机构
[1] Tokyo Med & Dent Univ, Dept Artificial Organs, Inst Biomat & Bioengn, Chiyoda Ku, Tokyo, Japan
[2] Nihon Univ, Coll Sci & Technol, Dept Mech Engn, Tokyo 102, Japan
[3] Shibaura Inst Technol, Dept Engn Mech, Tokyo 108, Japan
[4] Tokyo Denki Univ, Fac Sci & Engn, Dept Appl Elect Engn, Tokyo 101, Japan
[5] Tokyo Med & Dent Univ, Inst Biomat & Bioengn, Dept Thorac Organ Replacement, Tokyo, Japan
关键词
single-pivot bearing system; centrifugal blood pump; ventricular assist device; sealless continuous flow pump;
D O I
10.1046/j.1525-1594.2001.06856.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In order to develop a centrifugal blood pump that meets the requirements of a long-term, implantable circulatory support device, in this study a sing e-pivot bearing supported centrifugal blood pump was designed to evaluate its basic performance. The single-pivot structure consisted of a ceramic ball male pivot mounted on the bottom surface of the impeller and a polyethylene female pivot incorporated in the bottom pump casing. The follower magnet mounted inside the impeller was magnetically coupled to the driver magnet mounted on the shaft of the direct current brushless motor. As the motor rotated, the impeller rotated supported entirely by a single-pivot bearing system. The static pump performance obtained in the mock circulatory loop revealed an acceptable performance as a left ventricular assist device in terms of flow and head pressure. The pump flow of 5 L/min against the head pressure of 100 mm Hg was obtained at rotational speeds of 2,000 to 2,200 rpm. The maximum pump flow was 9 L/min with 2,200 rpm. The maximum electrical-to-hydraulic power conversion efficiency was around 14% at pump flows of 4 to 5 L/min. The stability of the impeller was demonstrated at the pump rpm higher than 1,400 with a single-pivot bearing without an additional support at its top. The single-pivot supported centrifugal pump can provide adequate flow and pressure as a ventricular assist device, but its mechanical stability and hemolytic as well as thrombotic performances must be tested prior to clinical use.
引用
收藏
页码:683 / 687
页数:5
相关论文
共 50 条
  • [11] The pivot wash in two impeller modes for the Baylor/Miwatec centrifugal blood pump
    Yamane, T
    Kodama, T
    Nishida, M
    Maruyama, O
    Yamamoto, Y
    Shinohara, T
    Motomura, T
    Nosé, Y
    ARTIFICIAL ORGANS, 2006, 30 (01) : 70 - 73
  • [12] Quantitative approach to control spinning stability of the impeller in the pivot bearing-supported centrifugal pump
    Takami, Y
    Makinouchi, K
    Otsuka, G
    Nose, Y
    ARTIFICIAL ORGANS, 1997, 21 (12) : 1292 - 1296
  • [13] Impeller design for a miniaturized centrifugal blood pump
    Takano, T
    Schulte-Eistrup, S
    Yoshikawa, M
    Nakata, K
    Kawahito, S
    Maeda, T
    Nonaka, K
    Linneweber, J
    Glueck, J
    Fujisawa, A
    Makinouchi, K
    Yokokawa, M
    Nosé, Y
    ARTIFICIAL ORGANS, 2000, 24 (10) : 821 - 825
  • [14] Quantitative approach to control spinning stability of the impeller in the pivot bearing-supported centrifugal pump
    Department of Surgery, Baylor College of Medicine, Houston, TX, United States
    不详
    Artif. Organs, 12 (1292-1296):
  • [15] DESIGN OF A CENTRIFUGAL BLOOD PUMP WITH MAGNETIC SUSPENSION
    YAMANE, T
    IKEDA, T
    ORITA, T
    TSUTSUI, T
    JIKUYA, T
    ARTIFICIAL ORGANS, 1995, 19 (07) : 625 - 630
  • [16] EVALUATION OF THE MAGLEV MOTOR AND DESIGN OF THE CENTRIFUGAL BLOOD PUMP FOR PEDIATRIC ARTIFICIAL HEART
    Osa, M.
    Masuzawa, T.
    Tatsumi, E.
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2011, 34 (08): : 609 - 609
  • [17] PARAMETER-ESTIMATION FOR SINGLE-PIVOT AND DUAL-PIVOT, KINEMATICAL NECK MODELS IN CRASH INJURY RESEARCH
    WOLTRING, HJ
    WISMANS, J
    JOURNAL OF BIOMECHANICS, 1985, 18 (07) : 555 - 555
  • [18] Modification of a pivot bearing system on a compact centrifugal pump
    Nakazawa, T
    Makinouchi, K
    Takami, Y
    Glueck, J
    Takatani, S
    Nose, Y
    ARTIFICIAL ORGANS, 1996, 20 (03) : 258 - 263
  • [19] Design, Manufacturing and Tests of an Implantable Centrifugal Blood Pump
    Bock, Eduardo
    Antunes, Pedro
    Uebelhart, Beatriz
    Leao, Tarcisio
    Fonseca, Jeison
    Cavalheiro, Andre
    Santos Filho, Diolino
    Cardoso, Jose Roberto
    Utiyama, Bruno
    Leme, Juliana
    Silva, Cibele
    Andrade, Aron
    Arruda, Celso
    TECHNOLOGICAL INNOVATION FOR SUSTAINABILITY, 2011, 349 : 410 - +
  • [20] Design considerations of volute geometry of a centrifugal blood pump
    Chan, WK
    Wong, YW
    Hu, W
    ARTIFICIAL ORGANS, 2005, 29 (12) : 937 - 948