Harmonic Power Standard of VTT MIKES

被引:4
|
作者
Lehtonen, Tapio A. [1 ]
机构
[1] VTT Tech Res Ctr Finland Ltd, Ctr Metrol MIKES, Espoo 02150, Finland
关键词
Current measurement; measurement; measurement standards; measurement uncertainty; power measurement; voltage measurement; CURRENT SHUNTS;
D O I
10.1109/TIM.2018.2880056
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper describes the new single-phase harmonic power standard developed at VTT MIKES. The standard is based on a custom digitizer, which is designed for both laboratory and on-site power metrology. Test signals are generated using a dual-channel arbitrary function generator, a voltage amplifier, and a transconductance amplifier. The reference voltage and current measurements are, respectively, based on a capacitive-resistive voltage divider and two different types of resistive shunt designs. Thorough characterization of the components is presented. Finally, a tentative uncertainty budget is drawn up for frequencies 53 Hz, 1 kHz, 10 kHz on power factors 1.0 and 0.0. The standard has an expanded uncertainty of 32 and 157 mu W/VA at 10 kHz for power factors of 1.0 and 0.0, respectively.
引用
收藏
页码:2047 / 2052
页数:6
相关论文
共 50 条
  • [22] Signal Processing for a Standard Harmonic Analyzer
    Trigo, Leonardo
    Slomovitz, Daniel
    2015 IEEE 6TH LATIN AMERICAN SYMPOSIUM ON CIRCUITS & SYSTEMS (LASCAS), 2015,
  • [23] A new method for measurement of harmonic groups in power systems using wavelet analysis in the IEC standard framework
    Barros, J
    Diego, RI
    ELECTRIC POWER SYSTEMS RESEARCH, 2006, 76 (04) : 200 - 208
  • [24] Indices for measurement of harmonic distortion in power systems according to IEC 61000-4-7 standard
    Dalali, Milad
    Jalilian, Alireza
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2015, 9 (14) : 1903 - 1912
  • [25] A Non-Standard Adaptive Control for Shunt Active Power Filter without Current Harmonic Detection
    Ribeiro, R. L. A.
    Azevedo, C. C.
    Sousa, R. M.
    IECON 2010 - 36TH ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2010,
  • [26] A HARMONIC POWER GENERATOR
    HOLLAND, D
    RUSSELL, GT
    ELECTRONICS AND POWER, 1969, 15 (JAN): : 17 - &
  • [27] HARMONIC POWER METER
    MCCURRY, EM
    STONE, RH
    TRI-SERVICE CONFERENCE ON ELECTROMAGNETIC COMPATIBILITY, 1964, (NOV): : 160 - &
  • [28] Harmonic power detection and measurement device based on harmonic power flow analysis
    Feng, GH
    Zhang, J
    Zhao, YS
    Ying, Y
    Zhang, BY
    ICEMS 2005: Proceedings of the Eighth International Conference on Electrical Machines and Systems, Vols 1-3, 2005, : 2262 - 2265
  • [29] Harmonic Power Detection and Measurement Device Based on Harmonic Power Flow Analysis
    Zhuang, Fuyu
    Cong, Peiting
    Zhuang, Geng
    2009 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY, VOLS 1-3, 2009, : 351 - +
  • [30] Algorithm for measurement and processing of results from total harmonic distortion calibration of power quality analyzers by using standard periodic non-harmonic signals
    Tzvetkov, Plamen Marinov
    Galabov, Krasimir Simeonov
    Kodjabashev, Ivan Nikolov
    2021 XXXI INTERNATIONAL SCIENTIFIC SYMPOSIUM METROLOGY AND METROLOGY ASSURANCE (MMA 2021), 2021, : 123 - 126