A Study of the Radiation Tolerance and Timing Properties of 3D Diamond Detectors

被引:4
|
作者
Anderlini, Lucio [1 ]
Bellini, Marco [2 ,3 ,4 ]
Cindro, Vladimir [5 ]
Corsi, Chiara [3 ]
Kanxheri, Keida [6 ,7 ]
Lagomarsino, Stefano [1 ,8 ]
Lucarelli, Chiara [1 ,4 ]
Morozzi, Arianna [7 ]
Passaleva, Giovanni [1 ]
Passeri, Daniele [7 ,9 ]
Sciortino, Silvio [1 ,2 ,4 ]
Servoli, Leonello [7 ]
Veltri, Michele [1 ,10 ]
机构
[1] Natl Inst Nucl Phys Florence, I-50019 Florence, Italy
[2] Natl Inst Opt CNR Florence, I-50019 Florence, Italy
[3] LENS European Lab Nonlinear Spect Florence, I-50019 Florence, Italy
[4] Univ Florence, Dept Phys & Astron, I-50019 Florence, Italy
[5] Jozef Stefan Inst, Ljubljana 1000, Slovenia
[6] Univ Perugia, Dept Phys & Geol, I-06100 Perugia, Italy
[7] Natl Inst Nucl Phys Perugia, I-06123 Perugia, Italy
[8] Univ Siegen, Lab Nanoopt, D-57076 Siegen, Germany
[9] Univ Perugia, Engn Dept, I-06123 Perugia, Italy
[10] Univ Urbino, Dept Pure & Appl Sci, I-61029 Urbino, Italy
关键词
CVD diamond; diamond sensors; laser engineering; timing measurements; radiation hardness;
D O I
10.3390/s22228722
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We present a study on the radiation tolerance and timing properties of 3D diamond detectors fabricated by laser engineering on synthetic Chemical Vapor Deposited (CVD) plates. We evaluated the radiation hardness of the sensors using Charge Collection Efficiency (CCE) measurements after neutron fluences up to 10(16) n/cm(2) (1 MeV equivalent.) The radiation tolerance is significantly higher when moving from standard planar architecture to 3D architecture and increases with the increasing density of the columnar electrodes. Also, the maximum applicable bias voltage before electric breakdown increases significantly after high fluence irradiation, possibly due to the passivation of defects. The experimental analysis allowed us to predict the performance of the devices at higher fluence levels, well in the range of 10(16) n/cm(2). We summarize the recent results on the time resolution measurements of our test sensors after optimization of the laser fabrication process and outline future activity in developing pixel tracking systems for high luminosity particle physics experiments.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Evaluation of a 3D diamond detector for medical radiation dosimetry
    Kanxheri, K.
    Servoli, L.
    Oh, A.
    Sanchez, F. Munoz
    Forcolin, G. T.
    Murphy, S. A.
    Aitkenhead, A.
    Moore, C. J.
    Morozzi, A.
    Passeri, D.
    Bellini, M.
    Corsi, C.
    Lagomarsino, S.
    Sciortino, S.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [22] Construction and characterisation of high time resolution 3D diamond pixel detectors
    Anderlini, L.
    Bellini, M.
    Corsi, C.
    Lagomarsino, S.
    Lucarelli, C.
    Passaleva, G.
    Sciortino, S.
    Veltri, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2023, 1046
  • [23] 3D Semiconductor radiation detectors for medical imaging: simulation and design
    Ruat, Marie
    d'Aillon, Eric Gros
    Verger, Loick
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 5241 - 5246
  • [24] The geometrical dependence of radiation hardness in planar and 3D silicon detectors
    Davia, C.
    Watts, S. J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 603 (03): : 319 - 324
  • [25] New 3D Silicon detectors for dosimetry in Microbeam Radiation Therapy
    Lerch, M. L. F.
    Dipuglia, A.
    Cameron, M.
    Fournier, P.
    Davis, J.
    Petasecca, M.
    Cornelius, I.
    Perevertaylo, V.
    Rosenfeld, A. B.
    MICRO-MINI & NANO-DOSIMETRY & INNOVATIVE TECHNOLOGIES IN RADIATION THERAPY (MMND&ITRO2016), 2017, 777
  • [26] 3D silicon detectors
    Bates, R. L.
    ASTROPARTICLE, PARTICLE, SPACE PHYSICS AND DETECTORS FOR PHYSICS APPLICATIONS, 2012, 7 : 829 - 840
  • [27] Radiochromic 3D Detectors
    Oldham, Mark
    8TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2015, 573
  • [28] Performance of 3D diamond detectors in small field dosimetry: The impact of pixel size
    Kanxheri, Keida
    Talamonti, Cinzia
    Sciortino, Silvio
    Lagomarsino, Stefano
    Ionica, Maria
    Caprai, Mirco
    Moscatelli, Francesco
    Servoli, Leonello
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 102 : 73 - 78
  • [29] A study of the thermoluminescent properties of CVD diamond detectors
    Marczewska, B
    Bilski, P
    Nesladek, M
    Olko, P
    Rebisz, M
    Waligórski, MPR
    PHYSICA STATUS SOLIDI A-APPLIED RESEARCH, 2002, 193 (03): : 470 - 475
  • [30] FlexyDos3D: a deformable anthropomorphic 3D radiation dosimeter: radiation properties
    De Deene, Y.
    Skyt, P. S.
    Hil, R.
    Booth, J. T.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (04): : 1543 - 1563