Boron and oxygen isotope composition of certified reference materials NIST SRM 610/612 and reference materials JB-2 and JR-2

被引:159
|
作者
Kasemann, S
Meixner, A
Rocholl, A
Vennemann, T
Rosner, M
Schmitt, AK
Wiedenbeck, M
机构
[1] Geoforschungszentrum Potsdam, D-14473 Potsdam, Germany
[2] Univ Tubingen, Inst Geochem, D-72076 Tubingen, Germany
来源
GEOSTANDARDS NEWSLETTER-THE JOURNAL OF GEOSTANDARDS AND GEOANALYSIS | 2001年 / 25卷 / 2-3期
关键词
reference material; in situ analysis; boron isotopes; oxygen isotopes; NIST SRM 610; NIST SRM 612; JB-2; JR-2;
D O I
10.1111/j.1751-908X.2001.tb00615.x
中图分类号
P [天文学、地球科学];
学科分类号
07 ;
摘要
We present data on the concentration, the isotope composition and the homogeneity of boron in NIST silicate glass reference materials SRM 610 and SRM 612, and in powders and glasses of geological reference materials JB-2 (basalt) and JR-2 (rhyolite). Our data are intended to serve as references for both microanalytical and wet-chemical techniques. The delta(11)B compositions determined by N-TIMS and P-TIMS agree within 0.5%(0) and compare with SIMS data within 2.5%(0). SIMS profiles demonstrate boron isotope homogeneity to better than delta(11)B = 2%(0) for both NIST glasses, however a slight boron depletion was detected towards the outermost 200 mum of the rim of each sample wafer. The boron isotope compositions of SRM 610 and SRM 612 were indistinguishable. Glasses produced in this study by fusing JB-2 and JR-2 powder also showed good boron isotope homogeneity both within and between different glass fragments. Their major element abundance as well as boron isotope compositions and concentrations were identical to those of the starting composition. Hence, reference materials (glasses) for the in situ measurement of boron isotopes can be produced from already well-studied volcanic samples without significant isotope fractionation. Oxygen isotope ratios, both within and between wafers, of NIST reference glasses SRM 610 and SRM 612 are uniform. In contrast to boron, significant differences in oxygen isotope compositions were found between the two glasses, which may be due to the different amounts of trace element oxides added at ten-fold different concentration levels to the silicate matrix.
引用
收藏
页码:405 / 416
页数:12
相关论文
共 50 条
  • [21] Analysis of the Physicochemical State of C-Reactive Protein in Different Preparations Including 2 Certified Reference Materials
    Rzychon, Malgorzata
    Zegers, Ingrid
    Schimmel, Heinz
    CLINICAL CHEMISTRY, 2010, 56 (09) : 1475 - 1482
  • [22] Toward the Development of Certified Reference Materials for Effective Biodiesel Testing. Part 2: Characterization and Value Assignment
    Ulberth-Buchgraber, Manuela
    Potalivo, Monica
    Held, Andrea
    ENERGY & FUELS, 2011, 25 (10) : 4630 - 4637
  • [23] Revised δ34S reference values for IAEA sulfur isotope reference materials S-2 and S-3
    Mann, Jacqueline L.
    Vocke, Robert D., Jr.
    Kelly, W. Robert
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2009, 23 (08) : 1116 - 1124
  • [24] The oxygen stable isotope composition of CRM 125-A UO2 standard reference material
    Oerter, Erik J.
    Singleton, Michael
    Pili, Eric
    Klosterman, Michael R.
    Shemesh, Aldo
    Agrinier, Pierre
    Deinhart, Amanda
    Yam, Ruth
    Assulin, Maor
    Elish, Eyal
    McDonald, Luther
    Tenner, Travis
    Kips, Ruth
    APPLIED GEOCHEMISTRY, 2022, 146
  • [25] Arsenobetaine and other arsenic compounds in the National Research Council of Canada Certified Reference Materials DORM 1 and DORM 2
    Goessler, W
    Kuehnelt, D
    Schlagenhaufen, C
    Slejkovec, Z
    Irgolic, KJ
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (03) : 183 - 187
  • [27] Certified DNA Reference Materials to Compare HER2 Gene Amplification Measurements Using Next-Generation Sequencing Methods
    Lih, Chih-Jian
    Si, Han
    Das, Biswajit
    Harrington, Robin D.
    Harper, Kneshay N.
    Sims, David J.
    McGregor, Paul M.
    Camalier, Corinne E.
    Kayserian, Andrew Y.
    Williams, P. Mickey
    He, Hua-Jun
    Almeida, Jamie L.
    Lund, Steve P.
    Choquette, Steve
    Cole, Kenneth D.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2016, 18 (05): : 753 - 761
  • [28] Ultraviolet laser sampling and high resolution inductively coupled plasma mass spectrometry of NIST and BCR-2G glass reference materials
    Lahaye, Y
    Lambert, D
    Walters, S
    GEOSTANDARDS NEWSLETTER-THE JOURNAL OF GEOSTANDARDS AND GEOANALYSIS, 1997, 21 (02): : 205 - 214
  • [29] POLYCYCLIC AROMATIC-COMPOUNDS OF ENVIRONMENTAL AND OCCUPATIONAL IMPORTANCE - THEIR OCCURRENCE, TOXICITY AND THE DEVELOPMENT OF HIGH-PURITY CERTIFIED REFERENCE MATERIALS .2.
    JACOB, J
    KARCHER, W
    BELLIARDO, JJ
    BELLIARDO, JJ
    WAGSTAFFE, PJ
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1986, 323 (01): : 1 - 10
  • [30] Revised δ34S reference values for IAEA sulfur isotope reference materials S-2 and S-3 (vol 23, pg 1116, 2009)
    Mann, Jacqueline L.
    Vocke, Robert D.
    Kelly, W. Robert
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2009, 23 (11) : 1746 - 1746